The Most Accurate Technique and Formulation for Prostate Volume Estimation: A Comparative Analysis of Transrectal Ultrasonography, Magnetic Resonance Imaging, and Three-Dimensional Segmentation

被引:0
|
作者
Citgez, Sinharib [1 ]
Sahin, Kadir C. [1 ]
Kalender, Goktug [1 ]
Gultekin, Mehmet H. [1 ]
Sayili, Ugurcan [2 ]
Sertbudak, Ipek [3 ]
Gurses, Iclal [3 ]
Ozkara, Hamdi [1 ]
机构
[1] Istanbul Univ Cerrahpasa, Cerrahpasa Fac Med, Dept Urol, Istanbul, Turkiye
[2] Istanbul Univ Cerrahpasa, Cerrahpasa Fac Med, Dept Publ Hlth, Istanbul, Turkiye
[3] Istanbul Univ Cerrahpasa, Cerrahpasa Fac Med, Dept Pathol, Istanbul, Turkiye
关键词
prostate; MRI; ultrasonography; 3D segmentation; ELLIPSOID FORMULA; MRI; ULTRASOUND; RISK; IMPACT;
D O I
10.1089/end.2024.0839
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Prostate volume estimation is of great importance for patient evaluation in a urologist's clinical practice. The accuracy and superiority of the techniques used in volume calculation have always been the subject of debate. Therefore, we conducted a comparative analysis between the volumes derived from transrectal ultrasonography (TRUS), multiparametric prostate magnetic resonance imaging (MpMRI), and three-dimensional (3D)-constructed MpMRI images of patients, who underwent retropubic radical prostatectomy at our institution.Methods: The data of patients with preoperative TRUS and MpMRI who underwent radical prostatectomy (Rp) in our clinic between August 2021 and February 2023 were retrospectively reviewed. The prostatectomy specimens were taken to the pathology department without exposure to any fixative and measured with the water displacement method. All axial T2-weighted sequences were segmented by a single surgeon using 3D Slicer (v. 5.6.2) software, and all measurements were compared with the specimen volume measured at the pathology laboratory.Results: A total of 150 patients were included in this study. The median prostate volumes estimated by TRUS-ellipsoid, TRUS-bullet, MpMRI, and 3D segmentation were 43.45 cc (min.-max.: 15.1-122.6), 54.32 cc (min.-max.: 18.9-153.3), 44.05 cc (min.-max.: 15.4-128.9), and 43.11 cc (min.-max.: 14.3-110.6), respectively. The median Rp specimen volume measurement in the pathology department was 42 cc (min.-max.: 12-114). When the measurement techniques were compared between each other, it has been shown that the statistically significant difference was caused by TRUS-bullet measurement. No statistically significant difference between the other three measurement techniques as well as between them and the specimen volume measurements were detected.Conclusion: Consistent with the findings of previous studies, MpMRI has provided estimations closer to pathology measurements and 3D segmentation allows even more precise measurements. However, considering accessibility, reproducibility, time efficiency, and cost, TRUS-based measurements can be safely used in clinical practice, especially using the ellipsoid formula.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Three-dimensional ultrashort echo time magnetic resonance imaging in pediatric patients with pneumonia: a comparative study
    Sun, Yan
    Chen, Yujie
    Li, Xuesheng
    Liao, Yi
    Chen, Xijian
    Song, Yu
    Liang, Xinyue
    Dai, Yongming
    Chen, Dapeng
    Ning, Gang
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [22] Two and Three-Dimensional Segmentation of Hyperpolarized 3He Magnetic Resonance Imaging of Pulmonary Gas Distribution
    Heydarian, Mohammadreza
    Kirby, Miranda
    Wheatley, Andrew
    Fenster, Aaron
    Parraga, Grace
    MEDICAL IMAGING 2012: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2012, 8317
  • [23] Three-Dimensional Contrast-Enhanced Ultrasonography of Intraductal Papillary Mucinous Neoplasms of the Pancreas A Comparison With Magnetic Resonance Imaging
    Pezzilli, Raffaele
    Serra, Carla
    Calculli, Lucia
    Ferroni, Fabio
    Iammarino, Maria Teresa
    Casadei, Riccardo
    PANCREAS, 2013, 42 (07) : 1164 - 1168
  • [24] Repeatability of a novel technique for in vivo measurement of three-dimensional patellar tracking using magnetic resonance Imaging
    Fellows, RA
    Hill, NA
    MacIntyre, NJ
    Harrison, MM
    Ellis, RE
    Wilson, DR
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (01) : 145 - 153
  • [25] Quantification of right ventricular volume in dogs: a comparative study between three-dimensional echocardiography and computed tomography with the reference method magnetic resonance imaging
    Sieslack, Anne K.
    Dziallas, Peter
    Nolte, Ingo
    Wefstaedt, Patrick
    Hungerbuehler, Stephan O.
    BMC VETERINARY RESEARCH, 2014, 10
  • [26] Three-dimensional Elastic Image Registration Based on Strain Energy Minimization: Application to Prostate Magnetic Resonance Imaging
    Zhang, Bao
    Arola, Dwayne D.
    Roys, Steve
    Gullapalli, Rao P.
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (04) : 573 - 585
  • [27] Underestimation of Left Atrial Volume by Three-Dimensional Echocardiography Validated by Magnetic Resonance Imaging: A Meta-Analysis and Investigation of the Source of Bias
    Shimada, Yuichi J.
    Shiota, Takahiro
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (04): : 385 - 390
  • [28] Three-dimensional Elastic Image Registration Based on Strain Energy Minimization: Application to Prostate Magnetic Resonance Imaging
    Bao Zhang
    Dwayne D. Arola
    Steve Roys
    Rao P. Gullapalli
    Journal of Digital Imaging, 2011, 24 : 573 - 585
  • [29] Magnetic Resonance Imaging: An Accurate, Radiation-Free, Alternative to Computed Tomography for the Primary Imaging and Three-Dimensional Reconstruction of the Bony Orbit
    Schmutz, Beat
    Rahmel, Benjamin
    McNamara, Zeb
    Coulthard, Alan
    Schuetz, Michael
    Lynham, Anthony
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 72 (03) : 611 - 618
  • [30] Accuracy of Three-Dimensional Ultrasonography in Differential Diagnosis of Septate and Bicornuate Uterus Compared with Office Hysteroscopy and Pelvic Magnetic Resonance Imaging
    Faivre, Erika
    Fernandez, Herve
    Deffieux, Xavier
    Gervaise, Amelie
    Frydman, Rene
    Levaillant, Jean Marc