Detection of highly sensitive Escherichia coli (E. coli) bacteria using an electrochemical sensor based on zinc oxide/polyvinyl alcohol nanocomposite

被引:0
|
作者
Ismardi, Abrar [1 ,5 ]
Gunawan, Luthfi Aprilio [1 ]
Winarsih, Suci [2 ]
Jatmika, Jumaeda [2 ]
Manurung, Robeth Viktoria [3 ]
Fathona, Indra Wahyudhin [1 ,5 ]
Suhendi, Asep [1 ,5 ]
Abdullah, Nor Hakimin [4 ]
Maulida, Sabrina [1 ]
Putri, Fadya Alifannisa [1 ]
Prihadni, Imaniar Wahyu [1 ]
Fariz, Bachtiar Nur [1 ]
机构
[1] Telkom Univ, Sch Elect Engn, Dept Engn Phys, Bandung 40257, West Java, Indonesia
[2] Natl Res & Innovat Agcy BRIN, Res Ctr Quantum Phys, South Tangerang 15314, Indonesia
[3] Natl Res & Innovat Agcy Republ Indonesia BRIN Band, Res Ctr Elect & Telecommun, Bandung, Indonesia
[4] Univ Malaysia Kelantan, Fac Bioengn & Technol, Adv Mat Res Ctr AMRC, Jeli 17600, Kelantan, Malaysia
[5] Telkom Univ, Univ Ctr Excellence Intelligent Sensing IoT, Bandung 40257, West Java, Indonesia
关键词
ZnO/PVA nanocomposite; Metal oxide semiconductor; Escherichia coli; Electrochemical; Electrode; Sensor; VOLTAMMETRIC DETERMINATION; BIOLOGICAL-FLUIDS; ZNO;
D O I
10.1016/j.microc.2024.112044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Escherichia coli (E. coli) bacteria is found in various water and food sources, posing a significant threat to human health by potentially causing several diseases. Therefore, this study aimed to explore the fabrication of electrochemical sensor based on ZnO/PVA nanocomposite. The fabrication was carried out using a screen-printed carbon electrode (SPCE), with ZnO/PVA nanocomposite serving as a modifying material on the working electrode through the drop-casting method. ZnO/PVA nanocomposite was characterized using Field Emission Scanning Electron Microscopy (FESEM), Transmission Electron Microscope (TEM), X-ray diffraction (XRD), I-V, and cyclic voltammetry electrochemistry. The results of FESEM characterization showed an even distribution of ZnO in PVA matrix with an average of 59 nm particle size. The modification of the working electrode with ZnO/ PVA nanocomposite showed an improved current response. Furthermore, a response time of approximately 3-5 min was achieved with a limit of detection (LOD) of 1.97 x 106 CFU during E. coli detection testing. This phenomenon enabled the prototype sensor to detect the presence of E. coli, shown by an increase in current generated during cyclic voltammetry testing. Based on the potential for further development, electrochemical sensor based on ZnO/PVA nanocomposite showed promise in becoming a leading option for E. coli detection.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Whole-cell Escherichia coli-based bio-sensor assay for dual zinc oxide nanoparticle toxicity mechanisms
    Mcquillan, Jonathan S.
    Shaw, Andrew M.
    BIOSENSORS & BIOELECTRONICS, 2014, 51 : 274 - 279
  • [42] DETECTION AND QUANTIFICATION OF E. COLI AND COLIFORM BACTERIA IN WATER SAMPLES WITH A NEW METHOD BASED ON FLUORESCENCE IN SITU HYBRIDISATION
    Huegler, Michael
    Boeckle, Karin
    Eberhagen, Ingrid
    Thelen, Karin
    Beimfohr, Claudia
    Hambsch, Beate
    SIGNIFICANCE OF FAECAL INDICATORS IN WATER: A GLOBAL PERSPECTIVE, 2012, : 123 - 130
  • [43] A highly sensitive electrochemical biosensor based on zinc oxide nanotetrapods for L-lactic acid detection
    Lei, Yang
    Luo, Ning
    Yan, Xiaoqin
    Zhao, Yanguang
    Zhang, Gong
    Zhang, Yue
    NANOSCALE, 2012, 4 (11) : 3438 - 3443
  • [44] Detection of Escherichia coli Using Highly Sensitive Surface Plasmon Resonance Nanostructure (SPRN) Based on MXene 2D Nanomaterial
    Daher, Malek G.
    Trabelsi, Youssef
    Ahmed, Naser M.
    Prajapati, Yogenra Kumar
    Rashed, Ahmed Nabih Zaki
    Patel, Shobhit K.
    PLASMONICS, 2023, 18 (06) : 2483 - 2492
  • [45] E. coli biosensor based on modular GFP and luxI/IuxR cyclic amplification circuit for sensitive detection of lysine
    Wang, Wenjia
    Zhang, Jing
    Tao, Hui
    Lv, Xuefei
    Deng, Yulin
    Li, Xiaoqiong
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (29-30) : 8299 - 8307
  • [46] Development and validation of a FISH-based method for the detection and quantification of E. coli and coliform bacteria in water samples
    Huegler, Michael
    Boeckle, Karin
    Eberhagen, Ingrid
    Thelen, Karin
    Beimfohr, Claudia
    Hambsch, Beate
    WATER SCIENCE AND TECHNOLOGY, 2011, 64 (07) : 1435 - 1442
  • [47] Selective and sensitive electrochemical detection of doxorubicin via a novel magnesium oxide/carbon dot nanocomposite based sensor
    Singh, Th. Abhishek
    Sharma, Vinit
    Thakur, Neelam
    Tejwan, Neeraj
    Sharma, Anirudh
    Das, Joydeep
    INORGANIC CHEMISTRY COMMUNICATIONS, 2023, 150
  • [48] Detection of Escherichia coli using CMOS array photo sensor-based enzyme biochip detection system
    Huang, Su-Hua
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (02) : 561 - 564
  • [49] Bio-modification of M13 bacteriophage as signal amplification container for the highly sensitive detection of live E. Coli
    Meng, Meng
    Jiang, Ying
    Li, Wang
    Wen, Qian
    Xiong, Ying
    Chen, Qi
    Ren, Jiali
    MICROCHEMICAL JOURNAL, 2023, 195
  • [50] A Highly Sensitive Impedimetric DNA Biosensor Based on Hollow Silica Microspheres for Label-Free Determination of E. coli
    Ariffin, Eda Yuhana
    Heng, Lee Yook
    Tan, Ling Ling
    Abd Karim, Nurul Huda
    Hasbullah, Siti Aishah
    SENSORS, 2020, 20 (05)