Synthesis of a new olivine reference material by a novel method for in situ iron and magnesium isotope analyses using laser ablation MC-ICP-MS

被引:0
作者
Zeng, Xianli [1 ]
Li, Ming [1 ]
Zhang, Wen [1 ]
Jin, Hongyun [2 ]
Liu, Yongsheng [1 ]
Hu, Zhaochu [1 ]
Luo, Tao [1 ]
Yang, Shengjun [1 ]
Liu, Zhenyan [1 ]
Wang, Jingyuan [1 ]
机构
[1] China Univ Geosci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
[2] China Univ Geosci, Fac Mat Sci & Chem, Wuhan 430074, Peoples R China
基金
国家重点研发计划;
关键词
MASS BIAS; FE; FEMTOSECOND; DIFFUSION; MANTLE; MATRIX; FRACTIONATION; STANDARD; SULFUR; RATIOS;
D O I
10.1039/d4ja00422a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Olivine is an important rock-forming mineral, and its stable Fe and Mg isotopes provide important indications for identifying important geological processes. In situ Fe and Mg isotopic analyses using laser ablation multiple-collector inductively coupled plasma-mass spectrometry (LA-MC-ICP-MS) have proven to be a powerful strategy for examining isotopic variations in olivine growth zoning. However, the advancement of this technology has been limited by the lack of matrix-matched reference materials. In this study, we developed an efficient protocol for preparing olivine reference materials by combining ultrafine powder preparation and solid-phase sintering techniques, specifically designed for Fe-Mg isotope analyses. The synthesized olivine sample, CUG-OL-Ar, retained the initial chemical properties and showed good laser ablation behavior and a stable signal profile. The ANOVA assessment demonstrated the excellent homogeneity of Fe and Mg isotope compositions in CUG-OL-Ar in different batches. The solution-MC-ICP-MS methods were used to determine the Fe and Mg isotope ratios in CUG-OL-Ar, while the uncertainties of Fe and Mg isotope ratios were calculated based on the ISO GUIDE. The assigned values of delta 56FeIRMM-014 and delta 25MgSC isotopes in CUG-OL-Ar were 0.00 +/- 0.06 parts per thousand (2SD, n = 350) and 0.00 +/- 0.05 parts per thousand (2SD, n = 350), respectively. The good results obtained through measuring Fe and Mg isotopes in different types of reference materials using LA-MC-ICP-MS with CUG-OL-Ar as the external standard proved the practicability and reliability of CUG-OL-Ar.
引用
收藏
页码:888 / 900
页数:13
相关论文
共 50 条
  • [21] A novel procedure for separating iron from geological materials for isotopic analysis using MC-ICP-MS
    Zhu, Guanhong
    Ma, Jinlong
    Wei, Gangjian
    An, Yajun
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (05) : 873 - 877
  • [22] A novel sample cell for reducing the "Position Effect" in laser ablation MC-ICP-MS isotopic measurements
    Xie, Lie-Wen
    Xu, Lei
    Yin, Qing-Zhu
    Yang, Yue-Heng
    Huang, Chao
    Yang, Jin-Hui
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (09) : 1571 - 1578
  • [23] Determination of Vanadium Isotope Compositions in Carbonates Using an Fe Coprecipitation Method and MC-ICP-MS
    Dong, Lin-Hui
    Wei, Wei
    Yu, Cheng-Long
    Hou, Zhen-Hui
    Zeng, Zhen
    Chen, Tianyu
    Huang, Fang
    [J]. ANALYTICAL CHEMISTRY, 2021, 93 (19) : 7172 - 7179
  • [24] An Analytical Method for Quantification of Sn Isotope Variations in Geological Materials Using MC-ICP-MS
    Pathak, Dipankar
    Mezger, Klaus
    [J]. GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, 48 (04) : 863 - 885
  • [25] Direct measurement of Fe isotope compositions in iron-dominated minerals without column chromatography using MC-ICP-MS
    Chen, Kaiyun
    Bao, Zhian
    Yuan, Honglin
    Lv, Nan
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (02) : 249 - 263
  • [26] An optimal separation method for high-precision K isotope analysis by using MC-ICP-MS with a dummy bucket
    Li, Xiaoqiang
    Han, Guilin
    Zhang, Qian
    Miao, Zhuang
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (07) : 1330 - 1339
  • [27] A rapid method of simultaneous chromatographic purification of Li and Mg for isotopic analyses using MC-ICP-MS
    Zhang, Wei
    Tanaka, Ryoji
    Kitagawa, Hiroshi
    Bohlin, Madeleine
    Nakamura, Eizo
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 480
  • [28] A high performance method for the accurate and precise determination of silicon isotopic compositions in bulk silicate rock samples using laser ablation MC-ICP-MS
    Zhang, Chenxi
    Zhao, He
    Zhang, Wen
    Luo, Tao
    Li, Ming
    Zong, Keqing
    Liu, Yongsheng
    Hu, Zhaochu
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (09) : 1887 - 1896
  • [29] New Potential Sphalerite, Chalcopyrite, Galena and Pyrite Reference Materials for Sulfur Isotope Determination by Laser Ablation-MC-ICP-MS
    Lv, Nan
    Bao, Zhian
    Chen, Kaiyun
    Zong, Chunlei
    Zhang, Yan
    Yuan, Honglin
    [J]. GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2022, 46 (03) : 451 - 463
  • [30] Determination of boron isotope compositions of geological materials by laser ablation MC-ICP-MS using newly designed high sensitivity skimmer and sample cones
    Lin, Lin
    Hu, Zhaochu
    Yang, Lu
    Zhang, Wen
    Liu, Yongsheng
    Gao, Shan
    Hu, Shenghong
    [J]. CHEMICAL GEOLOGY, 2014, 386 : 22 - 30