Diagnostic Accuracy of Cone-Beam CT for Acute Intracranial Hemorrhage: A Systematic Review and Meta-Analysis

被引:0
作者
Ferrone, Nicholas G. [1 ]
Sanmartin, Maria X. [1 ,3 ,4 ]
O'Hara, Joseph [1 ]
Jimenez, Jean [1 ]
Ferrone, Sophia R. [1 ,2 ]
Lodato, Zachary [1 ,2 ]
Lacher, Gregory [1 ,2 ]
Bandi, Sanjana [1 ,2 ]
Convey, Alicia [1 ,2 ]
Bastani, Mehrad [3 ,4 ]
Lee, Un Jung
Vialet, Jaclyn Morales [5 ]
White, Timothy [1 ,6 ]
Wang, Jason J. [1 ,7 ]
Katz, Jeffrey M. [1 ,8 ]
Sanelli, Pina C. [1 ,2 ,3 ,4 ,9 ,10 ]
机构
[1] Northwell Hlth, 2000 Marcus Ave, Suite 300, New Hyde Pk, NY 11042 USA
[2] Feinstein Inst Med Res, Inst Hlth Syst Sci, Manhasset, NY USA
[3] Donald & Barbara Zucker Sch Med Hofstra Northwell, Dept Radiol, Hempstead, NY USA
[4] Feinstein Inst Med Res, Dept Biostat, Manhasset, NY USA
[5] Northwell Hlth, Clin Med Lib, Manhasset, NY USA
[6] Donald & Barbara Zucker Sch Med Hofstra Northwell, Dept Neurol Surg, Hempstead, NY USA
[7] Donald & Barbara Zucker Sch Med Hofstra Northwell, Dept Radiol, Data Analyt, Hempstead, NY USA
[8] Donald & Barbara Zucker Sch Med Hofstra Northwell, Dept Neurol, Neurovasc Serv, Hempstead, NY USA
[9] Neiman Hlth Policy Inst, Chair Res, Dept Radiol, Reston, VA USA
[10] Neiman Hlth Policy Inst, PRIME Policy Res & Imaging Effectiveness Ctr, Reston, VA USA
关键词
Acute ischemic stroke; cone-beam CT; intracranial hemorrhage; ACUTE ISCHEMIC-STROKE; FLAT-DETECTOR CT; COMPUTED-TOMOGRAPHY; HEALTH-CARE; VISUALIZATION; THERAPY;
D O I
10.1016/j.jacr.2024.07.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Our purpose was to synthesize evidence in the literature to determine the diagnostic accuracy of cone-beam CT (CBCT) for the detection of intracranial hemorrhage (ICH) and hemorrhage types, including intraparenchymal hemorrhage (IPH), subarachnoid hemorrhage (SAH), and intraventricular hemorrhage (IVH). Methods: We performed a meta-analysis following the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines. Our protocol was registered with International Prospective Register of Systematic Reviews (PROSPERO-CRD42021261915). Systematic searches were last performed on April 30, 2024, in EMBASE, PubMed, Web-of-Science, Scopus, and Cumulative Index to Nursing and Allied Health Literature databases. Inclusion criteria were (1) studies reporting diagnostic metrics of CBCT for ICH and (2) studies using a reference standard to determine ICH. Exclusion criteria were (1) case reports, abstracts, reviews and (2) studies without patient-level data. Pooled estimates and 95% confidence intervals (CIs) were calculated for diagnostic odds ratios (DORs), sensitivity, and specificity using random-effects and common-effects models. Mixed methods appraisal tool was used to evaluate risk of bias. Results: Seven studies were included in the meta-analysis yielding 466 patients. Mean or median age ranged from 54 to 75 years. Female patients represented 51.4% (222 of 432) in reported studies. Multidetector CT was the reference standard in all studies. DOR, pooled sensitivity, and pooled specificity for ICH were 5.28 (95% CI: 4.11-6. 46), 0.88 (95% CI: 0.79-0.97), and 0.99 (95% CI: 0.98-1.0). Pooled sensitivity for IPH, SAH, and IVH was 0.98 (95% CI: 0.95-1.0), 0.82 (95% CI: 0.57-1.0), and 0.78 (95% CI: 0.55-1.0). Pooled specificity for IPH, SAH, and IVH was 0.99 (95% CI: 0.98-1.0), 0.99 (95% CI: 0.97-1.0), and 1.0 (95% CI: 0.98-1.0). Discussion: CBCT had moderate DOR and high pooled specificity for ICH and hemorrhage types. However, pooled sensitivity varied by hemorrhage type, with the highest sensitivity for IPH, followed by SAH and IVH.
引用
收藏
页码:1841 / 1850
页数:10
相关论文
共 31 条
  • [1] Evaluation of direct-to-angiography suite (DTAS) and conventional clinical pathways in stroke care: a simulation study
    Bastani, Mehrad
    White, Timothy G.
    Martinez, Gabriela
    Ohara, Joseph
    Sangha, Kinpritma
    Gribko, Michele
    Katz, Jeffrey M.
    Woo, Henry H.
    Boltyenkov, Artem T.
    Wang, Jason
    Rula, Elizabeth
    Naidich, Jason J.
    Sanelli, Pina C.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2022, 14 (12) : 1189 - +
  • [2] Systematic reviews of evaluations of diagnostic and screening tests - Odds ratio is not independent of prevalence
    Blackman, NJM
    [J]. BRITISH MEDICAL JOURNAL, 2001, 323 (7322): : 1188 - 1188
  • [3] Direct to angiography suite approaches for the triage of suspected acute stroke patients: a systematic review and meta-analysis
    Brehm, Alex
    Tsogkas, Ioannis
    Ospel, Johanna M.
    Appenzeller-Herzog, Christian
    Aoki, Junya
    Kimura, Kazumi
    Pfaff, Johannes A. R.
    Moehlenbruch, Markus A.
    Requena, Manuel
    Ribo, Marc J.
    Sarraj, Amrou
    Spiotta, Alejandro M.
    Sporns, Peter
    Psychogios, Marios-Nikos
    [J]. THERAPEUTIC ADVANCES IN NEUROLOGICAL DISORDERS, 2022, 15
  • [4] Systematic reviews in health care - Systematic reviews of evaluations of diagnostic and screening
    Deeks, JJ
    [J]. BRITISH MEDICAL JOURNAL, 2001, 323 (7305): : 157 - 162
  • [5] Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT
    Doelken, M.
    Struffert, T.
    Richter, G.
    Engelhorn, T.
    Nimsky, C.
    Ganslandt, O.
    Hammen, T.
    Doerfler, A.
    [J]. NEURORADIOLOGY, 2008, 50 (06) : 517 - 523
  • [6] Optimized Flat-Detector CT in Stroke Imaging: Ready for First-Line Use?
    Eckert, Matthias
    Goelitz, Philipp
    Luecking, Hannes
    Struffert, Tobias
    Knossalla, Frauke
    Doerfler, Arnd
    [J]. CEREBROVASCULAR DISEASES, 2017, 43 (1-2) : 9 - 16
  • [7] Voxel-Based Sensitivity of Flat-Panel CT for the Detection of Intracranial Hemorrhage: Comparison to Multi-Detector CT
    Froelich, Andreas M.
    Buhk, Jan-Hendrik
    Fiehler, Jens
    Kemmling, Andre
    [J]. PLOS ONE, 2016, 11 (11):
  • [8] Flat-Panel Volume CT: Fundamental Principles, Technology, and Applications
    Gupta, Rajiv
    Cheung, Arnold C.
    Bartling, Soenke H.
    Lisauskas, Jennifer
    Grasruck, Michael
    Leidecker, Christianne
    Schmidt, Bernhard
    Flohr, Thomas
    Brady, Thomas J.
    [J]. RADIOGRAPHICS, 2008, 28 (07) : 2009 - 2022
  • [9] The Mixed Methods Appraisal Tool (MMAT) version 2018 for information professionals and researchers
    Hong, Quan Nha
    Fabregues, Sergi
    Bartlett, Gillian
    Boardman, Felicity
    Cargo, Margaret
    Dagenais, Pierre
    Gagnon, Marie-Pierre
    Griffiths, Frances
    Nicolau, Belinda
    O'Cathain, Alicia
    Rousseau, Marie-Claude
    Vedel, Isabelle
    Pluye, Pierre
    [J]. EDUCATION FOR INFORMATION, 2018, 34 (04) : 285 - 291
  • [10] Flat-panel detector CT to assess intracranial hemorrhage immediately following mechanical thrombectomy
    Inoa, Violiza
    Dornbos, David
    DiNitto, Julie
    Martineau, David
    Sullivan, Joseph
    Angel, Jacqueline
    Nolan, Vikki G.
    Arthur, Adam S.
    Hoit, Daniel
    Nickele, Christopher
    Goyal, Nitin
    Elijovich, Lucas
    [J]. JOURNAL OF NEUROIMAGING, 2023, 33 (03) : 368 - 374