Transvenous extraction of conduction system and lumenless pacing leads

被引:0
作者
Wagner, Ethan S. [1 ]
Lewis, Robert K. [2 ]
Pokorney, Sean D. [2 ]
Hegland, Donald D. [2 ]
Friedman, Daniel J. [2 ]
Piccini, Jonathan P. [2 ]
机构
[1] Duke Univ, Sch Med, Durham, NC USA
[2] Duke Univ Hosp, Dept Med, Div Cardiol, Clin Cardiac Electrophysiol Sect, Durham, NC USA
关键词
conduction system pacing; His bundle pacing; laser lead extraction; left bundle branch area pacing; transvenous lead extraction; EXPERT CONSENSUS STATEMENT; PACEMAKER;
D O I
10.1111/jce.16467
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionConduction system pacing (CSP), often accomplished with lumenless pacing leads, is increasingly employed to achieve physiologic ventricular activation. There are limited data on the extraction of these leads. The objective of this study was to describe the safety and efficacy of extraction of CSP pacing leads and compare outcomes with extraction of non-CSP lumenless leads.MethodsPatients undergoing CSP/non-CSP lumenless lead removal were included. Outcomes of interest included rates of complete procedural success, complications, and successful reimplantation.ResultsOverall, 23 patients were included (n = 14 with CSP and n = 9 with non-CSP lumenless leads implanted in the right atrium, right ventricle, or septum). The mean age was 52.7 +/- 24.0 years, 30% were female, and the mean lead age was 4.5 +/- 4.4 years. The complete procedural success rate was 100%. One serious complication occurred in the non-CSP group but was unrelated to the lead of interest. Manual traction alone was successful in 57% of CSP cases (mean lead age 2.4 +/- 1.7 years) and in 11% of non-CSP cases (mean lead age 7.9 +/- 5.3 years). Laser sheaths were used in 43% of CSP cases and 89% of non-CSP cases; rotational cutting tools were used in no CSP cases and in 33% of non-CSP cases. Reimplantation in the conduction system was attempted with a left bundle branch pacing lead and successful in 80% (n = 4/5).ConclusionExtraction of CSP and non-CSP lumenless leads is feasible with a high success rate and a good safety profile. CSP reimplantation after extraction is also feasible with good electrical performance. Extraction of CSP and non-CSP lumenless leads is feasible with a high success rate and a good safety profile. CSP reimplantation after extraction is also feasible with good electrical performance.image
引用
收藏
页码:2432 / 2443
页数:12
相关论文
共 30 条
  • [1] Extraction of a fractured pacemaker lead in the left bundle branch area using a snare via a femoral approach
    Aguilera Agudo, Cristina
    Garcia-Izquierdo Jaen, Eusebio
    Jimenez Sanchez, Diego
    Castro Urda, Victor
    Toquero Ramos, Jorge
    Fernandez Lozano, Ignacio
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (02) : 239 - 240
  • [2] Initial experience with transvenous lead extraction of His bundle pacing leads
    Boczar, Krzysztof
    Zabek, Andrzej
    Golinska-Grzybala, Karolina
    Gajek, Jacek
    Holcman, Katarzyna
    Kostkiewicz, Magdalena
    Lelakowski, Jacek
    [J]. KARDIOLOGIA POLSKA, 2023, 81 (7-8) : 775 - 777
  • [3] Transvenous extraction of His bundle pacing lead: New challenge in the field of lead extraction
    Boczar, Krzysztof
    Zabek, Andrzej
    Debski, Maciej
    Gajek, Jacek
    Elakowski, Jacek L.
    Malecka, Barbara
    [J]. CARDIOLOGY JOURNAL, 2019, 26 (06) : 805 - 805
  • [4] 2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS
    Bongiorni, Maria G.
    Burri, Haran
    Deharo, Jean C.
    Starck, Christoph
    Kennergren, Charles
    Saghy, Laszlo
    Rao, Archana
    Tascini, Carlo
    Lever, Nigel
    Kutarski, Andrzej
    Lozano, Ignacio Fernandez
    Strathmore, Neil
    Costa, Roberto
    Epstein, Laurence
    Love, Charles
    Blomstrom-Lundqvist, Carina
    Fauchier, Laurent
    Defaye, Pascal
    Arnar, David O.
    Klug, Didier
    Boveda, Serge
    Nielsen, Jens Cosedis
    Boriani, Giuseppe
    Zhang, Shu
    Martin, Andrew Paul
    Prutkin, Jordan M.
    de Zuloaga, Claudio
    [J]. EUROPACE, 2018, 20 (07): : 1217 - +
  • [5] The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) Registry of Transvenous Lead Extraction Outcomes
    Bongiorni, Maria Grazia
    Kennergren, Charles
    Butter, Christian
    Deharo, Jean Claude
    Kutarski, Andrzej
    Rinaldi, Christopher A.
    Romano, Simone L.
    Maggioni, Aldo P.
    Andarala, Maryna
    Auricchio, Angelo
    Kuck, Karl-Heinz
    Blomstrom-Lundqvist, Carina
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 (40) : 2995 - 3005
  • [6] Burri H, 2023, EUROPACE, V25, P1208, DOI 10.1093/europace/euad043
  • [7] Computed tomography imaging-identified location and electrocardiographic characteristics of left bundle branch area pacing in bradycardia patients
    Chen, Keping
    Liu, Xingbin
    Hou, Xiaofeng
    Qiu, Yuanhao
    Lin, Jinxuan
    Dai, Yan
    Xu, Yuanning
    Jiang, Lingyun
    Zhou, Xiaohong
    Zhang, Xue
    Lu, Hongyang
    Mara, Nicki
    Demmer, Wade
    Cheng, Alan
    Zou, Jiangang
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (06) : 1244 - 1254
  • [8] Repositioning and extraction of stylet-driven pacing leads with extendable helix used for left bundle branch area pacing
    de Waroux, Jean-Benoit le Polain
    Wielandts, Jean-Yves
    Gillis, Kris
    Hilfiker, Gabriela
    Sorgente, Antonio
    Capulzini, Lucio
    Geerts, Bert
    Knecht, Sebastien
    Duytschaever, Mattias
    Tavernier, Rene
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (05) : 1464 - 1466
  • [9] Lumenless Pacing Leads: Performance and Extraction in Pediatrics and Congenital Heart Disease
    Garnreiter, Jason
    Whitaker, Patricia
    Pilcher, Thomas
    Etheridge, Susan
    Saarel, Elizabeth
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (01): : 42 - 47
  • [10] Prevalence of tricuspid regurgitation and pericardial effusions following pacemaker and defibrillator lead extraction
    Glover, B. M.
    Watkins, S.
    Mariani, J. A.
    Yap, S.
    Asta, J.
    Cusimano, R. J.
    Ralph-Edwards, A. C.
    Cameron, D. A.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (03) : 593 - 594