EXPERIMENTAL INVESTIGATION OF THE THERMAL PERFORMANCE OF A PROTOTYPE DIRECT-EXPANSION SOLAR-ASSISTED HEAT PUMP SYSTEM IN A COLD CLIMATE

被引:0
作者
Abbasi, Bardia [1 ]
Li, Simon [1 ]
Mwesigye, Aggrey [1 ]
机构
[1] Univ Calgary, Schulich Sch Engn, Dept Mech & Mfg Engn, Calgary, AB, Canada
来源
PROCEEDINGS OF ASME 2024 18TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, ES2024 | 2024年
基金
加拿大自然科学与工程研究理事会;
关键词
Coefficient of performance; direct expansion; energy analysis; solar-assisted heat pump; water heater;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Direct-expansion solar-assisted heat pumps (DX-SAHP) take advantage of solar energy to enhance the efficiency of conventional air-source heat pumps. However, their performance in very cold climates is not well understood. In this study, a prototype DX-SAHP is developed to experimentally characterize performance under realistic operating conditions. The system consists of a 2.3 m(2) solar collector with a serpentine heat exchanger as an evaporator, a scroll compressor with a rated power input of 0.6 kW, an expansion valve, a coaxial coil heat exchanger as the condenser, and a 178 L water storage tank. A set of experiments was conducted under realistic outdoor air conditions to assess the system's thermal performance. The system achieved an average coefficient of performance (COP) of 3.1 on a sunny day in winter to raise the water tank temperature from 16.1 degrees C to 50.3 degrees C in 4.5 hours. Conversely, the minimum average COP of 3.0 was recorded on an overcast summer day, raising the water temperature from 27.3 degrees C to 49.5 degrees C in 3.5 hours, while the system achieved its highest average COP of 3.44 on a sunny summer day. The highest instantaneous COP during the operation was 4.33, recorded in summer. However, the system was unable to operate continuously during overcast winter days, due to inadequate available thermal energy.
引用
收藏
页数:10
相关论文
共 22 条
[1]   Investigation of the thermodynamic performance of a direct-expansion solar-assisted heat pump under very cold climatic conditions with and without glazing [J].
Abbasi, Bardia ;
Li, Simon ;
Mwesigye, Aggrey .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 158 :329-344
[2]  
[Anonymous], Fluke Solar Irradiance Meter | Fluke
[3]  
[Anonymous], Performance Series: Standard Electric-Rheem.Ca
[4]  
[Anonymous], Packless 3/4 Ton Helix Copper Condenser Coil with Brackets | COAX-2076-H | Refrigerative Supply
[5]  
[Anonymous], PN2000 Watt Meter | Poniie
[6]  
[Anonymous], GREEN BUILDINGS
[7]  
[Anonymous], Copeland Scroll 0.75-3 HP ZF*KA for Refrigeration | Emerson US
[8]  
[Anonymous], 2019, ANSI/ASHRAE Addendum a to ANSI/ASHRAE Standard 34-2019
[9]  
[Anonymous], Astro Express 2 Hot Water Recirculation System | Armstrong Fluid Technology
[10]  
[Anonymous], Air to Water Heat Pump Specifications for Cold Weather-Arctic Heat Pumps