Seismic response and design of base-isolated hillside stilted structures

被引:0
作者
Li, Ruifeng [1 ]
Liu, Liping [1 ]
Lei, Haiming [1 ]
Li, Yingmin [1 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2025年 / 103卷
基金
美国国家科学基金会;
关键词
Seismic response; Direct displacement-based seismic design; Hillside stilted structures; Base isolation; Shaking table tests; BUILDINGS;
D O I
10.1016/j.jobe.2025.112217
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Established studies and seismic site investigations have revealed that hillside stilted structures suffer more serious damage compared with ordinary structures on flat ground due to their stiffness irregularities. However, studies on mitigating stiffness irregularities and enhancing seismic performance of stilted structures are limited. In this study, isolation bearings are introduced for the first time into the base of stilted columns, forming a base-isolated stilted structure, with the aim of controlling structural seismic response and mitigating stiffness irregularities. A series of shaking table tests were conducted on both a base-isolated stilted frame and a fixed-base stilted frame. Then, the stiffness of a stilted column-bearing tandem system was analyzed to determine the deformation of stilted columns under uniform stiffness distribution conditions. Finally, a direct displacement-based seismic design method for base-isolated stilted frames was proposed, and its validity was verified through time history analysis of 7-storey and 3-storey stilted building design cases. Test results demonstrated that installing seismic isolation bearings at the base of the stilted columns effectively reduced the seismic response of the stilted structure, verifying the effectiveness of the bearing arrangement. The results of the time-history analysis closely match the design values, and the errors in floor shear, displacement, and bearing deformation remain within 10 %, confirming the validity of the design method. Moreover, the difference in shear force among stilted columns of different lengths remains less than 10 %, indicating that using the proposed design method effectively achieves the objective of mitigating stiffness irregularities.
引用
收藏
页数:18
相关论文
共 46 条
  • [41] Varum H, 2018, IMPACTS AND INSIGHTS OF THE GORKHA EARTHQUAKE, P47, DOI 10.1016/B978-0-12-812808-4.00003-1
  • [42] Seismic response of a stilted mid-story isolated structure in mountainous areas based on variable parameters soil-structure-interaction effect
    Wan, Feng
    Zhou, Wangwang
    Liu, Dewen
    Huo, Yiran
    Li, Hui
    Luo, Xiaoxuan
    Yao, Shunzhong
    [J]. STRUCTURES, 2023, 51 : 707 - 717
  • [43] Stability of Elastomeric and Lead-Rubber Seismic Isolation Bearings
    Weisman, Jared
    Warn, Gordon P.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2012, 138 (02): : 214 - 222
  • [44] Wu Shaowei, 2024, J. Vib. Shock, V43
  • [45] Seismic performance of indoor substation RC frames with combined base isolation techniques
    Yin, Congru
    Song, Tiange
    Song, Xiaobin
    Gu, Xianglin
    Xiao, Xuwen
    [J]. ENGINEERING STRUCTURES, 2023, 284
  • [46] Evaluating effectiveness and optimum design of isolation devices for highway bridges using the fragility function method
    Zhang, Jian
    Huo, Yili
    [J]. ENGINEERING STRUCTURES, 2009, 31 (08) : 1648 - 1660