Flexural Response of UHPC Wet Joints Subjected to Vibration Load: Experimental and Theoretical Investigation

被引:0
|
作者
Zhao, Bin [1 ]
Yang, Jun [2 ,3 ]
Qin, Dingsong [1 ]
Zou, Yang [2 ,3 ]
Zhang, Zhongya [2 ,3 ]
Zhang, Kaijie [2 ,3 ]
Leng, Jingchen [2 ,3 ]
机构
[1] China Railway First Grp Co Ltd, Xian 710054, Peoples R China
[2] Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing 400074, Peoples R China
[3] Chongqing Jiaotong Univ, Sch Civil Engn, Chongqing 400074, Peoples R China
关键词
ultra-high performance concrete; live-load vibration; joints; flexural strength; PERFORMANCE;
D O I
10.3390/buildings15030496
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aims to investigate the flexural performance of ultra-high-performance concrete (UHPC) wet joints subjected to vibration load during the early curing period. The parameters investigated included vibration amplitude (1 mm, 3 mm, and 5 mm) and vibration stage (pouring-final setting, pouring-initial setting, and initial setting-final setting). A novel simulated vibration test set-up was developed to reproduce the actual vibration conditions of the joints. The actuator's reaction force time-history curves for the UHPC joint indicate that the reaction force is stable during the initial setting stage, and it increases linearly with time from the initial setting to the final setting, trending toward stability after 16 h of casting. Under the vibration of 3 Hz-5 mm, cracks measuring 14 cm x 0.2 mm emerge in the UHPC joint. It occurs during the stage from the initial setting to the final setting. The flexural performance of wet joint specimens after vibration was evaluated by the four-point flexural test, focusing on failure modes, load-deflection curves, and the interface opening. The results show that all specimens with joints exhibited bending failure, with cracks predominantly concentrated at the interfaces and the sides of the NC precast segment. The interfacial bond strength was reduced by vibrations of higher amplitude and frequency. Compared with the specimens without vibration, the flexural strength of specimens subjected to the vibration at 3 Hz-3 mm and 3 Hz-5 mm were decreased by 8% and 19%, respectively. However, as the amplitude and frequency decreased, the flexural strength of the specimens showed an increasing trend, as this type of vibration enhanced the compactness of the concrete. Additionally, the calculation model for the flexural strength of UHPC joints has been established, taking into account the impact of live-load vibration. The average ratio of theoretical calculation values to experimental values is 1.01, and the standard deviation is 0.04, the theoretical calculation value is relatively precise.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Experimental and numerical study of the flexural response of Ultra High Performance Concrete (UHPC) beams reinforced with GFRP
    Mahaini, Zin
    Abed, Farid
    Alhoubi, Yazan
    Elnassar, Zeinah
    COMPOSITE STRUCTURES, 2023, 315
  • [22] Experimental Investigation on Flexural Response of Hybrid Steel Plate Girder
    Kulkarni, A. S.
    Gupta, L. M.
    KSCE JOURNAL OF CIVIL ENGINEERING, 2018, 22 (07) : 2502 - 2518
  • [23] Experimental and numerical investigation of composite bolted π-joint subjected to bending load
    Fan, Jingfeng
    Cheng, Xiaoquan
    Wang, Songwei
    Guo, Xin
    Zhang, Tao
    COMPOSITES PART B-ENGINEERING, 2015, 78 : 324 - 330
  • [24] Experimental and theoretical investigation of an impact vibration harvester with triboelectric transduction
    Ibrahim, Alwathiqbellah
    Ramini, Abdallah
    Towfighian, Shahrzad
    JOURNAL OF SOUND AND VIBRATION, 2018, 416 : 111 - 124
  • [25] Experimental investigation of the influence of fibre content on the flexural performance of simply supported and continuous steel/UHPC composite slabs
    Chen, Sirui
    Visintin, Phillip
    Oehlers, Deric J.
    STEEL AND COMPOSITE STRUCTURES, 2023, 49 (05) : 571 - 585
  • [26] Experimental Study on Flexural Resistance of UHPC Wet Joint Precast Reinforced Concrete Bridge Deck Slabs with Variable Cross-Section
    Hu, Jiaqi
    Gu, Yin
    Yan, Jinhuang
    Sun, Ying
    Huang, Xinyi
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [27] Experimental investigation on duration of load effect of novel inorganic-bonded bamboo composite under flexural load
    Zhang, Xin
    Zhao, Mingyun
    Zhao, Ernian
    Li, Shuming
    Liu, Qiaoling
    Yue, Qingxia
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 421
  • [28] NUMERICAL AND EXPERIMENTAL INVESTIGATION OF LOAD SHARING IN COMPOSITE BONDED-BOLTED JOINTS
    Bodjona, Kobye
    Lim, Gyu-Hyeong
    Raju, Karthik Prasanna
    Lessard, Larry
    20TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS, 2015,
  • [29] Experimental investigation on compressive and flexural behavior of composite concrete systems incorporating UHPC under chloride-sulfate attack
    Zhu, Jinsong
    Al-samawi, Mohammed
    Al-Shakhdha, Najm Addin
    Farouk, A. I. B.
    Liu, Zhouqiang
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 448
  • [30] Experimental investigation and design optimization on flexural behavior of new UHPC deck panel with longitudinal ribs reinforced by steel plates
    Shao, Zongxuan
    Huai, Chenzi
    Cao, Junhui
    Li, Chong
    Shao, Xudong
    STRUCTURES, 2022, 43 : 878 - 895