Sagittal accuracy and functional impact of tibial slope in imageless robotic-assisted Total Knee Arthroplasty

被引:0
|
作者
Eggermont, Erwan [1 ]
Janssens, Raphael [2 ]
Ulrix, Maarten [1 ]
Fils, Jean-Francois [3 ]
Hernigou, Jacques [4 ,5 ]
Everaert, Johnatan [1 ]
Baillon, Bruno [1 ,2 ]
机构
[1] Univ libre Bruxelles, Brussels, Belgium
[2] Iris South Hosp Grp, Dept Orthopaed Surg, Brussels, Belgium
[3] Ars Stat SRL, Nivelles, Belgium
[4] Ath Hosp, Orthopaed Dept, EPICURA Baudour, Nivelles, Hainaut, Belgium
[5] Univ Mons, Mons, Belgium
关键词
Posterior tibial slope; Robotic-assisted; Total knee arthroplasty; Sagittal accuracy; OKS; KOOS; ROBUST ESTIMATION; MECHANICAL AXIS; ALIGNMENT; ANGLE;
D O I
10.1007/s00264-025-06472-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeStudy of the sagittal accuracy of the 'Robotic Surgical Assistant' (ROSA (R)), compared to conventional surgery, regarding the application of the tibial slope (TS). Study of the impact of TS on the range of motion (ROM) and patient-reported outcome measures (PROMS).MethodsInclusion of patients who underwent primary Total Knee Arthroplasty (TKA) between 1/1/2021 and 15/4/2024. Divided into robotic-assisted TKA (RA-TKA) and manual TKA (M-TKA). Measurement of pre- and post-operative TS, using the posterior tibial cortex, on profile knee X-rays. 3 degrees TS applied arbitrarily for both groups. ROM was measured pre-operatively and at three, six and 12 months post-operatively. Patient satisfaction assessed via Knee Injury and Osteoarthritis Outcome Score (KOOS) and Oxford Knee Score (OKS).Results266 patients were included in the study. The M-TKA (110) had a post-operative TS of 3.11 degrees (+/- 2.12 degrees). 81.21% were within 2 degrees of the target and 92.87% within 3 degrees. The RA-TKA (82) had a post-operative TS of -0.11 degrees +/- (1.93 degrees). 36.83% were within 2 degrees of the target and 56.63% within 3 degrees. RA-TKA had a KOOS of 64.43 +/- 12.87 and OKS of 33.05 +/- 6.01. M-TKA had a KOOS of 64.18 +/- 13.11 and OKS of 32.31 +/- 5.97. Maximum flexion at 12 months was 118.74 degrees +/- 8.19 degrees for M-TKA and 121.88 degrees +/- 7.43 degrees for RA-TKA (p = 0.002).ConclusionThe application of TS using ROSA (R) was less precise than the conventional method in achieving post-operative TS values as measured on X-rays. However, there were no clinical differences in ROM or PROMS.
引用
收藏
页码:1387 / 1394
页数:8
相关论文
共 50 条
  • [41] Handheld imageless robotic total knee arthroplasty improves accuracy and early clinical outcomes when compared with navigation
    Tran, Joshua Yeuk-Shun
    Tang, Abbie Yan-Tung
    Wong, Cham-Kit
    Lam, Gloria Yan-Ting
    Choi, Tsz-Lung
    Mak, Rex Wang-Fung
    Ng, Jonathan Patrick
    Ho, Kevin Ki-Wai
    Ong, Michael Tim-Yun
    Yung, Patrick Shu-Hang
    ARTHROPLASTY, 2025, 7 (01)
  • [42] Posterior tibial slope after total knee arthroplasty is not reproducible or consistent
    Demir, Ekin Baris
    Barca, Fatih
    Ucak, Mert
    Atilla, Halis Atil
    Akdogan, Mutlu
    Ates, Yalim
    KNEE, 2025, 54 : 136 - 145
  • [43] Assessment of accuracy of an imageless hand-held robotic-assisted system in component positioning in total knee replacement: a prospective study
    Vaidya, Narendra
    Jaysingani, Tanmay N.
    Panjwani, Taufiq
    Patil, Rakesh
    Deshpande, Ajinkya
    Kesarkar, Abhinav
    JOURNAL OF ROBOTIC SURGERY, 2022, 16 (02) : 361 - 367
  • [44] Assessment of accuracy of an imageless hand-held robotic-assisted system in component positioning in total knee replacement: a prospective study
    Narendra Vaidya
    Tanmay N. Jaysingani
    Taufiq Panjwani
    Rakesh Patil
    Ajinkya Deshpande
    Abhinav Kesarkar
    Journal of Robotic Surgery, 2022, 16 : 361 - 367
  • [45] Predictive Accuracy Analysis of a Novel Robotic-Assisted System for Total Knee Arthroplasty:A Prospective Observational Study
    Miao, Haichuan
    Zhu, Zhiyong
    Wang, Huisheng
    Bai, Xizhuang
    Li, Xi
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2024, 20 : 473 - 482
  • [46] What are the benefits of robotic-assisted total knee arthroplasty over conventional manual total knee arthroplasty? A systematic review of comparative studies
    Mancino, Fabio
    Cacciola, Giorgio
    Malahias, Michael-Alexander
    De Filippis, Roberto
    De Marco, Davide
    Di Matteo, Vincenzo
    Gu, A.
    Sculco, Peter K.
    Maccauro, Giulio
    De Martino, Ivan
    ORTHOPEDIC REVIEWS, 2020, 12 : 15 - 22
  • [47] Comparison of Time Taken in Conventional versus Active Robotic-Assisted Total Knee Arthroplasty
    Londhe, Sanjay Bhalchandra
    Shetty, Santosh
    Shetty, Vijay
    Desouza, Clevio
    Banka, Paras
    Antao, Nicholas
    CLINICS IN ORTHOPEDIC SURGERY, 2024, 16 (02) : 259 - 264
  • [48] Learning curve analysis of robotic-assisted total knee arthroplasty with a Chinese surgical system
    Zhang, Haoran
    Bai, Xizhuang
    Wang, Huisheng
    Zhu, Zhiyong
    Li, Xi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [49] Robotic-assisted technology does not influence functional outcomes among obese and morbidly obese total knee arthroplasty patients
    Brian P. McCormick
    Sarah Trent
    Xue Geng
    Ji Won Lee
    Henry R. Boucher
    Journal of Experimental Orthopaedics, 10
  • [50] Robotic-assisted technology does not influence functional outcomes among obese and morbidly obese total knee arthroplasty patients
    McCormick, Brian P. P.
    Trent, Sarah
    Geng, Xue
    Lee, Ji Won
    Boucher, Henry R. R.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2023, 10 (01)