Sagittal accuracy and functional impact of tibial slope in imageless robotic-assisted Total Knee Arthroplasty

被引:0
|
作者
Eggermont, Erwan [1 ]
Janssens, Raphael [2 ]
Ulrix, Maarten [1 ]
Fils, Jean-Francois [3 ]
Hernigou, Jacques [4 ,5 ]
Everaert, Johnatan [1 ]
Baillon, Bruno [1 ,2 ]
机构
[1] Univ libre Bruxelles, Brussels, Belgium
[2] Iris South Hosp Grp, Dept Orthopaed Surg, Brussels, Belgium
[3] Ars Stat SRL, Nivelles, Belgium
[4] Ath Hosp, Orthopaed Dept, EPICURA Baudour, Nivelles, Hainaut, Belgium
[5] Univ Mons, Mons, Belgium
关键词
Posterior tibial slope; Robotic-assisted; Total knee arthroplasty; Sagittal accuracy; OKS; KOOS; ROBUST ESTIMATION; MECHANICAL AXIS; ALIGNMENT; ANGLE;
D O I
10.1007/s00264-025-06472-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeStudy of the sagittal accuracy of the 'Robotic Surgical Assistant' (ROSA (R)), compared to conventional surgery, regarding the application of the tibial slope (TS). Study of the impact of TS on the range of motion (ROM) and patient-reported outcome measures (PROMS).MethodsInclusion of patients who underwent primary Total Knee Arthroplasty (TKA) between 1/1/2021 and 15/4/2024. Divided into robotic-assisted TKA (RA-TKA) and manual TKA (M-TKA). Measurement of pre- and post-operative TS, using the posterior tibial cortex, on profile knee X-rays. 3 degrees TS applied arbitrarily for both groups. ROM was measured pre-operatively and at three, six and 12 months post-operatively. Patient satisfaction assessed via Knee Injury and Osteoarthritis Outcome Score (KOOS) and Oxford Knee Score (OKS).Results266 patients were included in the study. The M-TKA (110) had a post-operative TS of 3.11 degrees (+/- 2.12 degrees). 81.21% were within 2 degrees of the target and 92.87% within 3 degrees. The RA-TKA (82) had a post-operative TS of -0.11 degrees +/- (1.93 degrees). 36.83% were within 2 degrees of the target and 56.63% within 3 degrees. RA-TKA had a KOOS of 64.43 +/- 12.87 and OKS of 33.05 +/- 6.01. M-TKA had a KOOS of 64.18 +/- 13.11 and OKS of 32.31 +/- 5.97. Maximum flexion at 12 months was 118.74 degrees +/- 8.19 degrees for M-TKA and 121.88 degrees +/- 7.43 degrees for RA-TKA (p = 0.002).ConclusionThe application of TS using ROSA (R) was less precise than the conventional method in achieving post-operative TS values as measured on X-rays. However, there were no clinical differences in ROM or PROMS.
引用
收藏
页码:1387 / 1394
页数:8
相关论文
共 50 条
  • [31] Surgical accuracy of image-free versus image-based robotic-assisted total knee arthroplasty
    Yee, Dennis King-Hang
    Ng, Jonathan Patrick
    Lau, Cyrus Tsun-Kit
    Ho, Kevin Ki-Wai
    Man, Gene Chi-Wai
    Chu, Vikki Wing-Shan
    Choi, Tsz Lung
    Lam, Gloria Yan Ting
    Ong, Michael Tim-Yun
    Yung, Patrick Shu-Hang
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (01)
  • [32] Versatility and accuracy of a novel image-free robotic-assisted system for total knee arthroplasty
    Vivek Singh
    Greg M. Teo
    William J. Long
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 2077 - 2086
  • [33] Image-Free Robotic-Assisted Total Knee Arthroplasty Improves Implant Alignment Accuracy: A Cadaveric Study
    Doan, Gary W.
    Courtis, R. Patrick
    Wyss, Joseph G.
    Green, Eric W.
    Clary, Chadd W.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (04) : 795 - 801
  • [34] Versatility and accuracy of a novel image-free robotic-assisted system for total knee arthroplasty
    Singh, Vivek
    Teo, Greg M.
    Long, William J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2077 - 2086
  • [35] The Use of Navigation or Robotic-Assisted Technology in Total Knee Arthroplasty Does Not Reduce Postoperative Pain
    Zak, Stephen Gerard
    Yeroushalmi, David
    Tang, Alex
    Meftah, Morteza
    Schnaser, Erik
    Schwarzkopf, Ran
    JOURNAL OF KNEE SURGERY, 2023, 36 (04) : 439 - 444
  • [36] Learning Curve in Robotic-Assisted Total Knee Arthroplasty: A Systematic Review of the Literature
    Cacciola, Giorgio
    Bosco, Francesco
    Giustra, Fortunato
    Risitano, Salvatore
    Capella, Marcello
    Bistolfi, Alessandro
    Masse, Alessandro
    Sabatini, Luigi
    APPLIED SCIENCES-BASEL, 2022, 12 (21):
  • [37] Robotic-assisted Unicompartmental Knee Arthroplasty
    Tamam, Cuneyt
    Poehling, Gary G.
    SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2014, 22 (04) : 219 - 222
  • [38] The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty
    Hyuk-Soo Han
    Seung-Baik Kang
    Chris H. Jo
    Sun-Hong Kim
    Jung-Ha Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 1334 - 1338
  • [39] Time-Based Learning Curve for Robotic-Assisted Total Knee Arthroplasty: A Multicenter Study
    Chen, Zhongming
    Bhowmik-Stoker, Manoshi
    Palmer, Matthew
    Coppolecchia, Andrea
    Harder, Benjamin
    Mont, Michael A.
    Marchand, Robert C.
    JOURNAL OF KNEE SURGERY, 2023, 36 (08) : 873 - 877
  • [40] The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty
    Han, Hyuk-Soo
    Kang, Seung-Baik
    Jo, Chris H.
    Kim, Sun-Hong
    Lee, Jung-Ha
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (10) : 1334 - 1338