Zero Background Visualizing Phosphorescence Lateral Flow Immunoassay of Cardiac Troponin I for Rapid and Accurate Diagnosis of Myocardial Infarction

被引:4
作者
Song, Qingwei [1 ,2 ]
Liao, Zixuan [1 ]
Zheng, Lin [3 ]
Fu, Pan [1 ]
Qian, Sihua [1 ]
Liang, Wei [3 ]
Zheng, Jianping [1 ]
Wang, Kaizhe [1 ]
Wang, Yuhui [1 ]
机构
[1] Chinese Acad Sci, Ningbo Inst Mat Technol & Engn, Ningbo 315201, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Ningbo Univ, Affiliated Hosp 1, Dept Clin Lab, Ningbo 315010, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
CARBON-DOTS; NANOPARTICLES; ASSAYS; PERFORMANCE; ULTRALONG;
D O I
10.1021/acs.analchem.4c06258
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fluorescence lateral flow immunoassays (FL-LFIA) have attracted considerable attention in clinical diagnosis due to their outstanding merits of affordable, sensitive, on-site, and quick detection. However, they are still plagued by significant signal interference, such as autofluorescence and scattered light. The development of high-performance and robust phosphors, i.e., label probes featuring with the character of low/no optical background, remains a great challenge. Herein, we report a novel visualized phosphorescence LFIA (Phos-LFIA), where the composite microspheres, i.e., carbon dots (CDs) covalently embedded in dendritic mesoporous silicon nanoparticles (DMSNs), were designed and selected as the report probes. The obtained CDs@DMSNs revealed uniform morphologies and particle sizes, as well as ultralong (lifetime: 1.14 s, visible for over 8 s to naked eyes) room temperature phosphorescence (RTP) in aqueous solution. As competitive nanotags, CDs@DMSNs were designed for an ultralong phosphorescence-based time-gated LFIA for cardiac troponin I (cTnI) without optical interference. The fabricated Phos-LFIA test strips demonstrated zero-background signal and were applied for highly sensitive cTnI detection in both buffer and a complex serum matrix, with corresponding limits of detection (LODs) of 0.19 and 0.21 ng/mL, respectively. For a clinical validation, the proposed Phos-LFIA revealed an excellent clinical analytical performance (sensitivity: 95.45%, specificity: 88.9%, kappa value: 0.85), demonstrating its potential for rapid and accurate diagnosis of myocardial infarction. This work provided a promising background-free probe for FL-LFIA, and it would also open an opportunity for developing highly sensitive screening platforms for other targets through modifying different recognition ligands onto CDs@DMSNs.
引用
收藏
页码:3651 / 3660
页数:10
相关论文
共 63 条
[1]   Wettability and surface charge of Si3N4-bioglass composites in contact with simulated physiological liquids [J].
Amaral, M ;
Lopes, MA ;
Santos, JD ;
Silva, RF .
BIOMATERIALS, 2002, 23 (20) :4123-4129
[2]   Ultrabright nanoparticle-labeled lateral flow immunoassay for detection of anti-SARS-CoV-2 neutralizing antibodies in human serum [J].
Bian, Lun ;
Li, Zhaoyue ;
He, An ;
Wu, Biru ;
Yang, Hui ;
Wu, Yingsong ;
Hu, Fang ;
Lin, Guanfeng ;
Zhang, Deqing .
BIOMATERIALS, 2022, 288
[3]  
Collet JP, 2021, REV ESP CARDIOL, V74, DOI [10.1016/j.rec.2021.05.002, 10.1093/eurheartj/ehaa575]
[4]   An Emerging Fluorescent Carbon Nanobead Label Probe for Lateral Flow Assays and Highly Sensitive Screening of Foodborne Toxins and Pathogenic Bacteria [J].
Deng, Chen ;
Li, Hui ;
Qian, Sihua ;
Fu, Pan ;
Zhou, Hualan ;
Zheng, Jianping ;
Wang, Yuhui .
ANALYTICAL CHEMISTRY, 2022, 94 (33) :11514-11520
[5]   Size-Dependent Immunochromatographic Assay with Quantum Dot Nanobeads for Sensitive and Quantitative Detection of Ochratoxin A in Corn [J].
Duan, Hong ;
Huang, Xiaolin ;
Shao, Yanna ;
Zheng, Lingyan ;
Guo, Liang ;
Xiong, Yonghua .
ANALYTICAL CHEMISTRY, 2017, 89 (13) :7062-7068
[6]   Diagnostics on acute myocardial infarction: Cardiac troponin biomarkers [J].
Fathil, M. F. M. ;
Arshad, M. K. Md ;
Gopinath, Subash C. B. ;
Hashim, U. ;
Adzhri, R. ;
Ayub, R. M. ;
Ruslinda, A. R. ;
Nuzaihan, M. M. N. ;
Azman, A. H. ;
Zaki, M. ;
Tang, Thean-Hock .
BIOSENSORS & BIOELECTRONICS, 2015, 70 :209-220
[7]   Organic Materials with Ultrabright Phosphorescence at Room Temperature under Physiological Conditions for Bioimaging [J].
Gu, Juqing ;
Yuan, Wentao ;
Chang, Kai ;
Zhong, Cheng ;
Yuan, Yufeng ;
Li, Jinghua ;
Zhang, Yufeng ;
Deng, Tian ;
Fan, Yuanyuan ;
Yuan, Likai ;
Liu, Siwei ;
Xu, Yongzhen ;
Ling, Sisi ;
Li, Chunyan ;
Zhao, Zheng ;
Li, Qianqian ;
Li, Zhen ;
Tang, Ben Zhong .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2025, 64 (03)
[8]   Dual-excitation carbon dots-based lateral flow visual sensing device for ratiometric determination and discrimination of tetracyclines in food [J].
Guo, Guoqiang ;
Li, Tingting ;
Zheng, Qi ;
Tang, Siyuan ;
Hu, Houwen ;
Wang, Xu ;
Chen, Da .
SENSORS AND ACTUATORS B-CHEMICAL, 2023, 395
[9]   Afterglow Nanoprobe-Enabled Quantitative Lateral Flow Immunoassay by a Palm-Size Device for Household Healthcare [J].
Guo, Jiuchuan ;
Zhou, Yudong ;
Cheng, Jie ;
Chen, Fuli ;
Xu, Jiahui ;
Yang, Lirong ;
Shi, Huifang ;
An, Zhongfu ;
Guo, Jinhong ;
Ma, Xing .
ANALYTICAL CHEMISTRY, 2024, 96 (12) :4891-4900
[10]   Nanomaterial Labels in Lateral Flow Immunoassays for Point-of-Care-Testing [J].
Guo, Jiuchuan ;
Chen, Shuqin ;
Guo, Jinhong ;
Ma, Xing .
JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2021, 60 (60) :90-104