Development of a GAGG gamma camera for the imaging of prompt gammas during proton beam irradiation

被引:0
|
作者
Yamamoto, Seiichi [1 ]
Yamashita, Tomohiro [2 ]
Kobashi, Yusuke [2 ]
Yabe, Takuya [3 ]
Nakanishi, Kohei [4 ]
Akagi, Takashi [5 ]
Yamaguchi, Mitsutaka [3 ]
Kawachi, Naoki [3 ]
Kamada, Kei [6 ]
Yoshikawa, Akira [6 ]
Kataoka, Jun [1 ]
机构
[1] Waseda Univ, Fac Sci & Engn, Tokyo, Japan
[2] Kobe Proton Ctr, Kobe, Japan
[3] Natl Inst Quantum Sci & Technol QST, Takasaki Inst Adv Quantum Sci, Chiba, Japan
[4] Nagoya Univ, Grad Sch Med, Nagoya, Japan
[5] Hyogo Ion Beam Med Ctr, Tatsuno, Japan
[6] Tohoku Univ, New Ind Creat Hatchery Ctr NICHe, Sendai, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2024年 / 127卷
关键词
Proton; Gamma camera; PGs; Range; PXs; POSITRON-EMISSION-TOMOGRAPHY; RANGE VERIFICATION; PET SYSTEM; DELIVERY;
D O I
10.1016/j.ejmp.2024.104847
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Prompt gammas imaging (PGI) is a promising method for observing a beam's shape and estimating the range of the beam from outside a subject. However 2-dimensional images of prompt gammas (PGs) during irradiation of protons were still difficult to measure. To achieve PGI, we developed a new gamma camera and imaged PGs while irradiating a phantom by proton beams. We also simultaneously measured prompt X-ray (PX) images with an X-ray camera from opposed direction and compared the images. The developed gamma camera uses a 10 mm thick GAGG block optically coupled to a flat panel photomultiplier tube (FP-PMT), and it is contained in a 20 mm thick tungsten container with a pinhole collimator attached. A poly-methyl-methacrylate (PMMA) block was irradiated by proton beams with total number of the protons similar to the clinical level, and the gamma camera imaged PGs and X-ray camera imaged PXs simultaneously. For all of the tested beams, we could measure the beam shapes of the PGs and the PXs and the ranges could also be estimated from the images. For both PG and PX images, time sequential images and accumulated images could be derived. We confirmed that the PGI using our developed gamma camera, as well as PXI, is promising for beam imaging and range estimation in proton therapy.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Processing of prompt gamma-ray timing data for proton range measurements at a clinical beam delivery
    Werner, Theresa
    Berthold, Jonathan
    Hueso-Gonzalez, Fernando
    Koegler, Toni
    Petzoldt, Johannes
    Roemer, Katja
    Richter, Christian
    Rinscheid, Andreas
    Straessner, Arno
    Enghardt, Wolfgang
    Pausch, Guntram
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (10)
  • [42] Prompt gamma-ray imaging with a nuclear emulsion for in vivo dose verification in proton therapy
    Toshito, Toshiyuki
    Kimura, Mitsuhiro
    Ogino, Hiroyuki
    Shibamoto, Yuta
    Nakamura, Mitsuhiro
    Sato, Osamu
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [43] Evaluation of proton inelastic reaction models in Geant4 for prompt gamma production during proton radiotherapy
    Jeyasugiththan, Jeyasingam
    Peterson, Stephen W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (19) : 7617 - 7635
  • [44] Development of a YAP(Ce) camera for the imaging of secondary electron bremsstrahlung x-ray emitted during carbon-ion irradiation toward the use of clinical conditions
    Yamamoto, Seiichi
    Yamaguchi, Mitsutaka
    Akagi, Takashi
    Sasano, Makoto
    Kawachi, Naoki
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (13)
  • [45] Low Statistics Reconstruction of the Compton Camera Point Spread Function in 3D Prompt-γ Imaging of Ion Beam Therapy
    Lojacono, Xavier
    Richard, Marie-Helene
    Ley, Jean-Luc
    Testa, Etienne
    Ray, Cedric
    Freud, Nicolas
    Letang, Jean Michel
    Dauvergne, Denis
    Maxim, Voichita
    Prost, Remy
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3355 - 3363
  • [46] Potential margin reduction in prostate cancer proton therapy with prompt gamma imaging for online treatment verification
    Bertschi, Stefanie
    Stuetzer, Kristin
    Berthold, Jonathan
    Pietsch, Julian
    Smeets, Julien
    Janssens, Guillaume
    Richter, Christian
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 26
  • [47] Development and evaluation of an EMCCD based gamma camera for preclinical SPECT Imaging
    Soesbe, Todd C.
    Lewis, Matthew A.
    Richer, Edmond
    Slavine, Nikolai V.
    Antich, Peter P.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1516 - 1524
  • [48] Cherenkov-light imaging of induced positron distribution in liquid water after proton beam irradiation
    Yamamoto, Seiichi
    Yamashita, Tomohiro
    Kobashi, Yusuke
    Hirano, Yoshiyuki
    Akagi, Takashi
    Yokokawa, Hiromu
    Kataoka, Jun
    JOURNAL OF INSTRUMENTATION, 2022, 17 (11)
  • [49] Simulation Study of a 3-D Multislit Prompt Gamma Imaging System for Proton Therapy Monitoring
    Lu, Wenzhuo
    Zhang, Debin
    Fan, Peng
    Wang, Shi
    Wu, Zhaoxia
    Ma, Tianyu
    Liu, Yaqiang
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (03) : 355 - 365
  • [50] Design of a scintillator-based prompt gamma camera for boron-neutron capture therapy: Comparison of SrI2 and GAGG using Monte-Carlo simulation
    Kim, Minho
    Hong, Bong Hwan
    Cho, Ilsung
    Park, Chawon
    Min, Sun-Hong
    Hwang, Won Taek
    Lee, Wonho
    Kim, Kyeong Min
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (02) : 626 - 636