Development of a GAGG gamma camera for the imaging of prompt gammas during proton beam irradiation

被引:0
|
作者
Yamamoto, Seiichi [1 ]
Yamashita, Tomohiro [2 ]
Kobashi, Yusuke [2 ]
Yabe, Takuya [3 ]
Nakanishi, Kohei [4 ]
Akagi, Takashi [5 ]
Yamaguchi, Mitsutaka [3 ]
Kawachi, Naoki [3 ]
Kamada, Kei [6 ]
Yoshikawa, Akira [6 ]
Kataoka, Jun [1 ]
机构
[1] Waseda Univ, Fac Sci & Engn, Tokyo, Japan
[2] Kobe Proton Ctr, Kobe, Japan
[3] Natl Inst Quantum Sci & Technol QST, Takasaki Inst Adv Quantum Sci, Chiba, Japan
[4] Nagoya Univ, Grad Sch Med, Nagoya, Japan
[5] Hyogo Ion Beam Med Ctr, Tatsuno, Japan
[6] Tohoku Univ, New Ind Creat Hatchery Ctr NICHe, Sendai, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2024年 / 127卷
关键词
Proton; Gamma camera; PGs; Range; PXs; POSITRON-EMISSION-TOMOGRAPHY; RANGE VERIFICATION; PET SYSTEM; DELIVERY;
D O I
10.1016/j.ejmp.2024.104847
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Prompt gammas imaging (PGI) is a promising method for observing a beam's shape and estimating the range of the beam from outside a subject. However 2-dimensional images of prompt gammas (PGs) during irradiation of protons were still difficult to measure. To achieve PGI, we developed a new gamma camera and imaged PGs while irradiating a phantom by proton beams. We also simultaneously measured prompt X-ray (PX) images with an X-ray camera from opposed direction and compared the images. The developed gamma camera uses a 10 mm thick GAGG block optically coupled to a flat panel photomultiplier tube (FP-PMT), and it is contained in a 20 mm thick tungsten container with a pinhole collimator attached. A poly-methyl-methacrylate (PMMA) block was irradiated by proton beams with total number of the protons similar to the clinical level, and the gamma camera imaged PGs and X-ray camera imaged PXs simultaneously. For all of the tested beams, we could measure the beam shapes of the PGs and the PXs and the ranges could also be estimated from the images. For both PG and PX images, time sequential images and accumulated images could be derived. We confirmed that the PGI using our developed gamma camera, as well as PXI, is promising for beam imaging and range estimation in proton therapy.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Compton Camera and Prompt Gamma Ray Timing: Two Methods for In Vivo Range Assessment in Proton Therapy
    Hueso-Gonzalez, Fernando
    Fiedler, Fine
    Golnik, Christian
    Kormoll, Thomas
    Pausch, Guntram
    Petzoldt, Johannes
    Roemer, Katja E.
    Enghardt, Wolfgang
    FRONTIERS IN ONCOLOGY, 2016, 6
  • [32] Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification
    Nenoff, Lena
    Priegnitz, Marlen
    Janssens, Guillaume
    Petzoldt, Johannes
    Wohlfahrt, Patrick
    Trezza, Anna
    Smeets, Julien
    Pausch, Guntram
    Richter, Christian
    RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) : 534 - 540
  • [33] Measuring prompt gamma-ray emissions from elements found in tissue during passive-beam proton therapy
    Jeyasugiththan, Jeyasingam
    Camero, Jaime Nieto
    Symons, Julyan
    Jones, Pete
    Buffler, Andy
    Geduld, Dieter
    Peterson, Stephen W.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (02)
  • [34] Imaging of gamma photons emitted from actinium-225 and daughter radionuclides using a small field-of-view GAGG gamma camera
    Yamamoto, Seiichi
    Yoshino, Masao
    Shirasaki, Kenji
    Nakanishi, Kohei
    Kamada, Kei
    Yoshikawa, Akira
    Kataoka, Jun
    JOURNAL OF INSTRUMENTATION, 2025, 20 (03):
  • [35] Prompt X-ray imaging during irradiation with spread-out Bragg peak (SOBP) beams of carbon ions
    Yamamoto, Seiichi
    Yabe, Takuya
    Akagi, Takashi
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Kataoka, Jun
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 109
  • [36] Prompt Gamma Rays Detected with a BGO Block Compton Camera Reveal Range Deviations of Therapeutic Proton Beams
    Hueso-Gonzalez F.
    Pausch G.
    Petzoldt J.
    Romer K.E.
    Enghardt W.
    1600, Institute of Electrical and Electronics Engineers Inc. (01): : 76 - 86
  • [37] Noise evaluation of prompt-gamma technique for proton-therapy range verification using a Compton Camera
    Ortega, P. G.
    Torres-Espallardo, I.
    Boehlen, T. T.
    Cerutti, F.
    Chin, M. P. W.
    Ferrari, A.
    Gillam, J. E.
    Lacasta, C.
    Llosa, G.
    Oliver, J.
    Rafecas, M.
    Sala, P. R.
    Solevi, P.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [38] Development of coded-aperture imaging with a compact gamma camera
    Gmar, M
    Gal, O
    Le Goaller, C
    Ivanov, OP
    Potapov, VN
    Stepanov, VE
    Lainé, F
    Lamadie, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1682 - 1687
  • [39] Design Guidelines for a Double Scattering Compton Camera for Prompt-γ Imaging During Ion Beam Therapy: A Monte Carlo Simulation Study
    Richard, M. -H.
    Chevallier, M.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 87 - 94
  • [40] GaN-Based Readout Circuit System for Reliable Prompt Gamma Imaging in Proton Therapy
    Pandey, Vimal Kant
    Tan, Cherming
    Sangwan, Vivek
    APPLIED SCIENCES-BASEL, 2021, 11 (12):