Development of a GAGG gamma camera for the imaging of prompt gammas during proton beam irradiation

被引:0
|
作者
Yamamoto, Seiichi [1 ]
Yamashita, Tomohiro [2 ]
Kobashi, Yusuke [2 ]
Yabe, Takuya [3 ]
Nakanishi, Kohei [4 ]
Akagi, Takashi [5 ]
Yamaguchi, Mitsutaka [3 ]
Kawachi, Naoki [3 ]
Kamada, Kei [6 ]
Yoshikawa, Akira [6 ]
Kataoka, Jun [1 ]
机构
[1] Waseda Univ, Fac Sci & Engn, Tokyo, Japan
[2] Kobe Proton Ctr, Kobe, Japan
[3] Natl Inst Quantum Sci & Technol QST, Takasaki Inst Adv Quantum Sci, Chiba, Japan
[4] Nagoya Univ, Grad Sch Med, Nagoya, Japan
[5] Hyogo Ion Beam Med Ctr, Tatsuno, Japan
[6] Tohoku Univ, New Ind Creat Hatchery Ctr NICHe, Sendai, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2024年 / 127卷
关键词
Proton; Gamma camera; PGs; Range; PXs; POSITRON-EMISSION-TOMOGRAPHY; RANGE VERIFICATION; PET SYSTEM; DELIVERY;
D O I
10.1016/j.ejmp.2024.104847
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Prompt gammas imaging (PGI) is a promising method for observing a beam's shape and estimating the range of the beam from outside a subject. However 2-dimensional images of prompt gammas (PGs) during irradiation of protons were still difficult to measure. To achieve PGI, we developed a new gamma camera and imaged PGs while irradiating a phantom by proton beams. We also simultaneously measured prompt X-ray (PX) images with an X-ray camera from opposed direction and compared the images. The developed gamma camera uses a 10 mm thick GAGG block optically coupled to a flat panel photomultiplier tube (FP-PMT), and it is contained in a 20 mm thick tungsten container with a pinhole collimator attached. A poly-methyl-methacrylate (PMMA) block was irradiated by proton beams with total number of the protons similar to the clinical level, and the gamma camera imaged PGs and X-ray camera imaged PXs simultaneously. For all of the tested beams, we could measure the beam shapes of the PGs and the PXs and the ranges could also be estimated from the images. For both PG and PX images, time sequential images and accumulated images could be derived. We confirmed that the PGI using our developed gamma camera, as well as PXI, is promising for beam imaging and range estimation in proton therapy.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Development of a low-energy x-ray camera for the imaging of secondary electron bremsstrahlung x-ray emitted during proton irradiation for range estimation
    Ando, Koki
    Yamaguchi, Mitsutaka
    Yamamoto, Seiichi
    Toshito, Toshiyuki
    Kawachi, Naoki
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (12) : 5006 - 5020
  • [22] Imaging and range estimations of prompt X-rays using YAP(Ce) camera during particle-ion irradiation to phantoms with air cavities
    Kitano, M.
    Yamamoto, S.
    Yabe, T.
    Akagi, T.
    Toshito, T.
    Yamaguchi, M.
    Kawachi, N.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (08)
  • [23] Computational model for detector timing effects in Compton-camera based prompt-gamma imaging for proton radiotherapy
    Maggi, Paul
    Peterson, Steve
    Panthi, Rajesh
    Mackin, Dennis
    Yang, Hao
    He, Zhong
    Beddar, Sam
    Polf, Jerimy
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (12)
  • [24] Towards clinical application: prompt gamma imaging of passively scattered proton fields with a knife-edge slit camera
    Priegnitz, M.
    Barczyk, S.
    Nenoff, L.
    Golnik, C.
    Keitz, I.
    Werner, T.
    Mein, S.
    Smeets, J.
    Stappen, F. Vander
    Janssens, G.
    Hotoiu, L.
    Fiedler, F.
    Prieels, D.
    Enghardt, W.
    Pausch, G.
    Richter, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (22) : 7881 - 7905
  • [25] Development of a list-mode data acquisition system for prompt X-ray imaging during irradiation with carbon-ions
    Yamamoto, Seiichi
    Yabe, Takuya
    Akagi, Takashi
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Kataoka, Jun
    JOURNAL OF INSTRUMENTATION, 2023, 18 (04)
  • [26] Detection of mixed-range proton pencil beams with a prompt gamma slit camera
    Priegnitz, M.
    Helmbrecht, S.
    Janssens, G.
    Perali, I.
    Smeets, J.
    Stappen, F. Vander
    Sterpin, E.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02) : 855 - 871
  • [27] Advantages of using larger-diameter pinhole collimator for prompt X-ray imaging during irradiation with carbon ions
    Yamamoto, Seiichi
    Yabe, Takuya
    Akagi, Takashi
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Kataoka, Jun
    JOURNAL OF INSTRUMENTATION, 2022, 17 (09)
  • [28] Design and performance evaluation of a slit-slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study
    Malekzadeh, Etesam
    Rajabi, Hossein
    Tajik-Mansoury, Mohammad Ali
    Sabouri, Pouya
    Fiorina, Elisa
    Kalantari, Faraz
    MEDICAL PHYSICS, 2023, 50 (06) : 3701 - 3718
  • [29] Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy
    Moteabbed, M.
    Espana, S.
    Paganetti, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04) : 1063 - 1082
  • [30] Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system
    Ku, Youngmo
    Choi, Sehoon
    Cho, Jaeho
    Jang, Sehyun
    Jeong, Jong Hwi
    Kim, Sung Hun
    Cho, Sungkoo
    Kim, Chan Hyeong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (09) : 3140 - 3149