Development of a GAGG gamma camera for the imaging of prompt gammas during proton beam irradiation

被引:0
|
作者
Yamamoto, Seiichi [1 ]
Yamashita, Tomohiro [2 ]
Kobashi, Yusuke [2 ]
Yabe, Takuya [3 ]
Nakanishi, Kohei [4 ]
Akagi, Takashi [5 ]
Yamaguchi, Mitsutaka [3 ]
Kawachi, Naoki [3 ]
Kamada, Kei [6 ]
Yoshikawa, Akira [6 ]
Kataoka, Jun [1 ]
机构
[1] Waseda Univ, Fac Sci & Engn, Tokyo, Japan
[2] Kobe Proton Ctr, Kobe, Japan
[3] Natl Inst Quantum Sci & Technol QST, Takasaki Inst Adv Quantum Sci, Chiba, Japan
[4] Nagoya Univ, Grad Sch Med, Nagoya, Japan
[5] Hyogo Ion Beam Med Ctr, Tatsuno, Japan
[6] Tohoku Univ, New Ind Creat Hatchery Ctr NICHe, Sendai, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2024年 / 127卷
关键词
Proton; Gamma camera; PGs; Range; PXs; POSITRON-EMISSION-TOMOGRAPHY; RANGE VERIFICATION; PET SYSTEM; DELIVERY;
D O I
10.1016/j.ejmp.2024.104847
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Prompt gammas imaging (PGI) is a promising method for observing a beam's shape and estimating the range of the beam from outside a subject. However 2-dimensional images of prompt gammas (PGs) during irradiation of protons were still difficult to measure. To achieve PGI, we developed a new gamma camera and imaged PGs while irradiating a phantom by proton beams. We also simultaneously measured prompt X-ray (PX) images with an X-ray camera from opposed direction and compared the images. The developed gamma camera uses a 10 mm thick GAGG block optically coupled to a flat panel photomultiplier tube (FP-PMT), and it is contained in a 20 mm thick tungsten container with a pinhole collimator attached. A poly-methyl-methacrylate (PMMA) block was irradiated by proton beams with total number of the protons similar to the clinical level, and the gamma camera imaged PGs and X-ray camera imaged PXs simultaneously. For all of the tested beams, we could measure the beam shapes of the PGs and the PXs and the ranges could also be estimated from the images. For both PG and PX images, time sequential images and accumulated images could be derived. We confirmed that the PGI using our developed gamma camera, as well as PXI, is promising for beam imaging and range estimation in proton therapy.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Simultaneous imaging of prompt gamma photons and prompt X-rays during irradiation of proton beams to human torso phantom at clinical dose level
    Yamamoto, Seiichi
    Yamashita, Tomohiro
    Kobashi, Yusuke
    Yabe, Takuya
    Akagi, Takashi
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Yokokawa, Hiromu
    Sagisaka, Mayu
    Kataoka, Jun
    JOURNAL OF INSTRUMENTATION, 2023, 18 (07)
  • [2] A triple-imaging-modality system for simultaneous measurements of prompt gamma photons, prompt x-rays, and induced positrons during proton beam irradiation
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Nakanishi, Kohei
    Yabe, Takuya
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Miyake, Masayasu
    Tanaka, Kazuo S.
    Kataoka, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (05)
  • [3] Prompt Gamma Imaging of a Pencil Beam with a High Efficiency Compton Camera at a Clinical Proton Therapy Facility
    Hueso-Gonzalez, F.
    Petzoldt, J.
    Roemer, K. E.
    Schoene, S.
    Fiedler, F.
    Golnik, C.
    Kormoll, T.
    Pausch, G.
    Enghardt, W.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [4] Development of a Compton camera for prompt-gamma medical imaging
    Aldawood, S.
    Thirolf, P. G.
    Miani, A.
    Boehmer, M.
    Dedes, G.
    Gernhauser, R.
    Lang, C.
    Liprandi, S.
    Maier, L.
    Marinsek, T.
    Mayerhofer, M.
    Schaart, D. R.
    Lozano, I. Valencia
    Parodi, K.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 190 - 197
  • [5] Measurement of prompt gamma profiles in inhomogeneous targets with a knife-edge slit camera during proton irradiation
    Priegnitz, M.
    Helmbrecht, S.
    Janssens, G.
    Perali, I.
    Smeets, J.
    Stappen, F. Vander
    Sterpin, E.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12) : 4849 - 4871
  • [6] Test of Compton camera components for prompt gamma imaging at the ELBE bremsstrahlung beam
    Hueso-Gonzalez, F.
    Golnik, C.
    Berthel, M.
    Dreyer, A.
    Enghardt, W.
    Fiedler, F.
    Heidel, K.
    Kormoll, T.
    Rohling, H.
    Schoene, S.
    Schwengner, R.
    Wagner, A.
    Pausch, G.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [7] Hybrid imaging of prompt x-rays and induced positrons using a pinhole gamma camera during and after irradiation of protons
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Nakanishi, Kohei
    Yabe, Takuya
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Islam, Md Rafiqul
    Miyake, Masayasu
    Tanaka, Kazuo S.
    Kataoka, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11)
  • [8] Optimization of a YAP(Ce) prompt X-ray camera for imaging with spot scanning proton beams at clinical dose levels
    Yamamoto, Seiichi
    Yamashita, Tomohiro
    Kobashi, Yusuke
    Yabe, Takuya
    Akagi, Takashi
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Kataoka, Jun
    JOURNAL OF INSTRUMENTATION, 2023, 18 (12)
  • [9] 3D prompt gamma imaging for proton beam range verification
    Draeger, E.
    Mackin, D.
    Peterson, S.
    Chen, H.
    Avery, S.
    Beddar, S.
    Polf, J. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03)
  • [10] Simultaneous imaging of luminescence and prompt x-rays during irradiation with spot-scanning proton beams at clinical dose level
    Yamamoto, Seiichi
    Yamashita, Tomohiro
    Kobashi, Yusuke
    Yabe, Takuya
    Akagi, Takashi
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Kataoka, Jun
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (04)