Respiratory system mechanics during noninvasive proportional assist ventilation: A model study

被引:0
|
作者
Chen, Yuqing [1 ]
Yuan, Yueyang [2 ]
Zhang, Hai [1 ]
Li, Feng [1 ]
Li, Xingwang [3 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Chest Hosp, Dept Resp Med, Shanghai, Peoples R China
[2] Hu Nan City Univ, Sch Mech & Elect Engn, Yi Yang 413099, Peoples R China
[3] Shanghai Jiao Tong Univ, Bio X Inst, Shanghai, Peoples R China
关键词
assist ventilation; expiratory airflow; inspiration; noninvasive ventilation; proportional respiratory mechanics; PRESSURE-SUPPORT VENTILATION; DIAPHRAGM DYSFUNCTION; RESISTANCE; SIMULATION; SYNCHRONY; REACTANCE; INJURY;
D O I
10.1556/2060.2024.00453
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose: To assess the accuracies of airway resistance (R-aw) and compliance (C-rs) calculations using the expiratory time constant (RCexp) method as well as the accuracy of P-mus estimation in obstructive lung models. Methods: A Respironics V60 ventilator was connected to an active lung simulator. The driving pressure was maintained at 5-10 cmH(2)O and positive end-expiration pressure (PEEP) was 5 cmH(2)O. Maximal P-mus, estimated based on equations of motion and respiratory mechanical properties, was calculated by the RCexp method to derive respiratory system compliance (C-rs) and inspiratory (R-insp) and expiratory (R-exp) resistance. Results: During PAV, the assist proportion was adjusted to 55% and 40% with P-mus of 5 and 10 cmH(2)O, respectively. P-mus measurement errors were <20% of the preset values in most lung conditions. In the active lung model with PAV, an overestimation of Raw was found in the normal resistance condition, and R-insp was underestimated in the severe obstructive model (P < 0.01). Crs was overestimated significantly except in the severe obstructive model at a P-mus of 10 cmH(2)O (all P < 0.01). Using the RCexp method, the target of <= 20% between the calculated and preset values in airway resistance was achieved in most obstructive models at a P-mus of 5 cmH(2)O. Conclusions: The RCexp method might provide real-time assessments of respiratory mechanics (elastance and resistance) in the PAV mode. With low inspiratory effort, the estimation error was acceptable (<20%) in most obstructive lung models.
引用
收藏
页码:339 / 350
页数:12
相关论文
共 50 条
  • [1] Noninvasive proportional assist ventilation compared with noninvasive pressure support ventilation in hypercapnic acute respiratory failure
    Wysocki, M
    Richard, JC
    Meshaka, P
    CRITICAL CARE MEDICINE, 2002, 30 (02) : 323 - 329
  • [2] Noninvasive proportional assist ventilation for acute respiratory insufficiency - Comparison with pressure support ventilation
    Gay, PC
    Hess, DR
    Hill, NS
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (09) : 1606 - 1611
  • [3] Oscillatory resistance measured during noninvasive proportional assist ventilation
    Farré, R
    Mancini, M
    Rotger, M
    Ferrer, M
    Roca, J
    Navajas, D
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (05) : 790 - 794
  • [4] Noninvasive pressure support versus proportional assist ventilation in acute respiratory failure
    Miguel Fernández-Vivas
    Juan Caturla-Such
    Javier González de la Rosa
    José Acosta-Escribano
    Bernabé Álvarez-Sánchez
    José Cánovas-Robles
    Intensive Care Medicine, 2003, 29 : 1126 - 1133
  • [5] Noninvasive pressure support versus proportional assist ventilation in acute respiratory failure
    Fernández-Vivas, M
    Caturla-Such, J
    de la Rosa, JG
    Acosta-Escribano, J
    Alvarez-Sánchez, B
    Cánovas-Robles, J
    INTENSIVE CARE MEDICINE, 2003, 29 (07) : 1126 - 1133
  • [6] A method for noninvasive determination of inspiratory resistance during proportional assist ventilation
    Younes, M
    Kun, J
    Masiowski, B
    Webster, K
    Roberts, D
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (04) : 829 - 839
  • [7] Noninvasive proportional assist ventilation and pressure support ventilation during arm elevation in patients with chronic respiratory failure. A preliminary, physiologic study
    Poggi, Roberta
    Appendini, Lorenzo
    Polese, Guido
    Colombo, Roberto
    Donner, Claudio F.
    Rossi, Andrea
    RESPIRATORY MEDICINE, 2006, 100 (06) : 972 - 979
  • [8] Breathing effort during noninvasive proportional assist ventilation in patients with acute exacerbations of chronic respiratory failure.
    Gutheil, T
    Pankow, W
    Becker, H
    Juhasz, J
    Stammnitz, A
    Grote, L
    Peter, JH
    vonWichert, P
    MEDIZINISCHE KLINIK, 1997, 92 (01) : 85 - 89
  • [9] NONINVASIVE DETERMINATION OF RESPIRATORY SYSTEM MECHANICS DURING MECHANICAL VENTILATION FOR ACUTE RESPIRATORY-FAILURE
    GOTTFRIED, SB
    ROSSI, A
    HIGGS, BD
    CALVERLEY, PMA
    ZOCCHI, L
    BOZIC, C
    MILICEMILI, J
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1985, 131 (03): : 414 - 420
  • [10] Evaluation of a method for assessing respiratory mechanics during noninvasive ventilation
    Navajas, D
    Alcaraz, J
    Peslin, R
    Roca, J
    Farré, R
    EUROPEAN RESPIRATORY JOURNAL, 2000, 16 (04) : 704 - 709