How Electrical Storms Recur Over Time in Patients With Implantable Cardioverter Defibrillators - Subanalysis of the Nippon Storm Study -

被引:0
|
作者
Yasuoka, Ryobun [1 ]
Maruyama, Masahiro [1 ]
Nakazawa, Gaku [1 ]
Noda, Takashi [2 ]
Nitta, Takashi [3 ]
Aizawa, Yoshifusa [4 ]
Ohe, Tohru [5 ]
Kurita, Takashi [1 ]
机构
[1] Kindai Univ Hosp, Div Cardiol, 377-2 Ohno Higashi, Osaka 5898511, Japan
[2] Tohoku Univ, Grad Sch Med, Div Cardiol, Sendai, Japan
[3] Hanyu Gen Hosp, Saitama, Japan
[4] Tachikawa Med Ctr, Dept Res & Dev, Niigata, Japan
[5] Okayama City Hosp, Okayama, Japan
关键词
Electrical storm; Implantable cardioverter defibrillator; Primary prevention; Recurrent event analysis; CARDIAC-RESYNCHRONIZATION THERAPY; VENTRICULAR-TACHYCARDIA; CATHETER ABLATION; MANAGEMENT; DEATH; TERM; PHARMACOTHERAPY; PREVENTION; PREDICTORS; GUIDELINE;
D O I
10.1253/circj.CJ-24-0390
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Electrical storms (E-storms), defined as multiple fatal ventricular arrhythmias over a short period, negatively affect the prognosis of patients receiving an implantable cardioverter defibrillator or cardiac resynchronization therapy with a defibrillator (ICD/ CRT-D). However, the prognostic impact of recurrent E-storms has not been well elucidated. Methods and Results: We analyzed the association between E-storm recurrences and mortality using data from 1,274 participants in the Nippon Storm Study, a prospective observational study conducted at 48 ICD/CRT-D centers in Japan. Differences in E-storm recurrences by patient characteristics were evaluated using the mean cumulative function (MCF), which is the cumulative number of E-storm episodes per patient as a function of time. Patients with multiple E-storms had a 3.39-fold higher mortality risk than those without E-storms (95% confidence interval 1.82-6.28; P<0.01). However, there was no significant difference in mortality risk between patients with a single E-storm and those without E-storms. The MCF curve exhibited a slower ascent in patients who received primary prevention ICD/CRT-D than in those who received secondary prevention ICD/CRT-D. However, when analyzing only patients with E-storms, the MCF curves demonstrated comparable trajectories in both groups. Conclusions: E-storm recurrences may have a negative impact on prognosis. Once patients with primary prevention experience an E-storm episode, they face a similar risk of subsequent recurrent E-storms as patients with secondary prevention.
引用
收藏
页码:214 / 223
页数:10
相关论文
共 50 条
  • [1] The role of catheter ablation in the management of patients with implantable cardioverter defibrillators presenting with electrical storm
    Paraskevaidis, Stelios
    Konstantinou, Dimitrios
    Kolettas, Vassilios
    Stavropoulos, George
    Koutsakis, Athanasios
    Nikolaidou, Chrysovalantou
    Ziakas, Antonios
    Karvounis, Haralambos
    HELLENIC JOURNAL OF CARDIOLOGY, 2017, 58 (01) : 51 - 56
  • [2] Predictors of electrical storm recurrences in patients with implantable cardioverter-defibrillators
    Streitner, Florian
    Kuschyk, Juergen
    Veltmann, Christian
    Mahl, Eva
    Dietrich, Claudia
    Schimpf, Rainer
    Doesch, Christina
    Streitner, Ines
    Wolpert, Christian
    Borggrefe, Martin
    EUROPACE, 2011, 13 (05): : 668 - 674
  • [3] Electrical Storm in Patients with Implantable Cardioverter-Defibrillators Can It Be Forecast?
    Emkanjoo, Zahra
    Alihasani, Narges
    Alizadeh, Abolfath
    Tayyebi, Mohammad
    Bonakdar, Hamid
    Barakpour, Hamid
    Sadr-Ameli, Mohammad Ali
    TEXAS HEART INSTITUTE JOURNAL, 2009, 36 (06) : 563 - 567
  • [4] Electrical Storms in Patients with an Implantable Cardioverter Defibrillator
    Song, Pil Sang
    Kim, June Soo
    Shin, Dae-Hee
    Park, Jung Wae
    Bae, Ki In
    Lee, Chang Hee
    Jung, Dong Chae
    Ryu, Dong Ryeol
    On, Young Keun
    YONSEI MEDICAL JOURNAL, 2011, 52 (01) : 26 - 32
  • [5] Electrical storms in patients with an implantable cardioverter defibrillator: Primary vs. secondary prophylaxis
    Tint, Diana
    Micu, Sorin
    Petris, Antoniu
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2016, 628 (01) : 1 - 6
  • [6] Efficacy of antitachycardia pacing for electrical storms in patients with implantable defibrillators
    Hayashi, Hiroshi
    Shimizu, Wataru
    Iwasaki, Yuki
    Yodogawa, Kenji
    Noda, Takashi
    Nitta, Takashi
    Aizawa, Yoshifusa
    Ohe, Tohru
    Kurita, Takashi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (03) : 823 - 831
  • [7] Ranolazine in Patients With Implantable Cardioverter-Defibrillators Ready for Prime Time?
    Albert, Christine M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (06) : 646 - 649
  • [8] Clinical predictors and prognostic significance of electrical storm in patients with implantable cardioverter defibrillators
    Brigadeau, F
    Kouakam, C
    Klug, D
    Marquié, C
    Duhamel, A
    Mizon-Gérard, F
    Lacroix, D
    Kacet, S
    EUROPEAN HEART JOURNAL, 2006, 27 (06) : 700 - 707
  • [9] Long-term outcome of catheter ablation and other form of therapy for electrical storm in patients with implantable cardioverter-defibrillators
    Stanislaw Morawski
    Patrycja Pruszkowska
    Beata Sredniawa
    Radoslaw Lenarczyk
    Zbigniew Kalarus
    Journal of Interventional Cardiac Electrophysiology, 2017, 50 : 227 - 234
  • [10] Impact of atrial fibrillation/flutter on outcomes of patients with implantable cardioverter defibrillators: A sub-analysis of the Nippon Storm study
    Maruyama, Masahiro
    Yasuoka, Ryobun
    Nagano, Tomoya
    Nakazawa, Gaku
    Noda, Takashi
    Nitta, Takashi
    Aizawa, Yoshifusa
    Ohe, Tohru
    Kurita, Takashi
    JOURNAL OF CARDIOLOGY, 2021, 78 (03) : 244 - 249