Design and optimization of cooling-heating-electricity integrated storage systems in cold regions

被引:0
|
作者
Zhang, Lei [1 ]
Feng, Guohui [1 ]
Bi, Yang [1 ]
Huang, Kailiang [1 ]
Chang, Shasha [1 ]
Li, Ainong [1 ]
Li, Huanyu [1 ]
机构
[1] Shenyang Jianzhu Univ, Shenyang, Peoples R China
基金
国家重点研发计划;
关键词
Energy management; Energy flexibility; Photovoltaic/thermal heat pump; Energy storage; Optimization; Abbreviations; NZEB; CHE-ES; building; electricity integrated; phase-change energy; MOBO; ENERGY MANAGEMENT; PUMP ASHP; BATTERY; PERFORMANCE; PV; BUILDINGS; COLLECTOR; HOME; PCM;
D O I
10.1016/j.est.2024.115131
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The incorporation of renewable energy storage systems and energy management strategy is anticipated to alleviate utility grid strain and mitigate electric costs. To increase the energy flexibility and economy of the system, this research establishes a cooling-heating-electricity integrated energy storage (CHE-ES) system considering daily load regulation, cooling/heating load management, and electrical management strategy for a nearly zero-energy building in cold regions. Both single-objective and multi-objective optimizations are conducted for the CHE-ES system configurations, utilizing PV-battery energy storage, heat pump-thermal energy storage, and interactions between the building and utility grid on the TRNSYS and MOBO coupled platforms. The findings indicate that the multi-objective optimization system, which incorporates the energy management strategy, improves the system's energy flexibility and raises the annual performance factor by 10.45 %. Reductions are observed in energy consumption, the net present value of the system, levelized cost of energy, and carbon emissions by 9.10 %, 25.76 %, 16.65 %, and 94.01 %, respectively. The ongoing expansion of PV capacity allows the building to reach phases of zero operating cost for the system, zero energy consumption for the system, and zero energy consumption for the building. The optimal annual self-consumption ratio and load coverage ratio are found to be 0.45 and 0.94, enhancing energy flexibility of the building and the utility grid. The CHE-ES system requires power from the utility grid for load regulation when building demand is high but adjusts dynamically using PV and battery packs at other times. Government incentives play a crucial role in promoting zero-energy buildings. The CHE-ES system provides guidance for the integrated management of renewable energy systems, facilitating its widespread application in northern China.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Renewable energy systems for building heating, cooling and electricity production with thermal energy storage
    Zhang, Sheng
    Oclon, Pawel
    Klemes, Jiri Jaromir
    Michorczyk, Piotr
    Pielichowska, Kinga
    Pielichowski, Krzysztof
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 165
  • [2] Parametric life cycle assessment for distributed combined cooling, heating and power integrated with solar energy and energy storage
    Yan, Junchen
    Broesicke, Osvaldo A.
    Wang, Dong
    Li, Duo
    Crittenden, John C.
    JOURNAL OF CLEANER PRODUCTION, 2020, 250
  • [3] Parametrical analysis of latent heat and cold storage for heating and cooling of rooms
    Osterman, E.
    Hagel, K.
    Rathgeber, C.
    Butala, V.
    Stritih, U.
    APPLIED THERMAL ENGINEERING, 2015, 84 : 138 - 149
  • [4] Dynamic Optimization of Combined Cooling, Heating, and Power Systems with Energy Storage Units
    Kuang, Jiyuan
    Zhang, Chenghui
    Li, Fan
    Sun, Bo
    ENERGIES, 2018, 11 (09)
  • [5] Towards an integrated design of renewable electricity generation and storage systems for NZEB use: A parametric analysis
    Tumminia, Giovanni
    Sergi, Francesco
    Aloisio, Davide
    Longo, Sonia
    Cusenza, Maria Anna
    Guarino, Francesco
    Cellura, Salvatore
    Ferraro, Marco
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [6] Post-design system control for integrated space heating systems in residential buildings in cold regions
    Li, Xinming
    Guel, Mustafa
    Al-Hussein, Mohamed
    BUILDING AND ENVIRONMENT, 2015, 94 : 313 - 324
  • [7] Simultaneous design and operation optimization of renewable combined cooling heating and power systems
    Liu, Zuming
    Lim, Mei Qi
    Kraft, Markus
    Wang, Xiaonan
    AICHE JOURNAL, 2020, 66 (12)
  • [8] COMBINED SOLAR HEATING AND COOLING SYSTEMS: SIMULATION AND DESIGN OPTIMIZATION
    Nurzia, Giovanni
    Franchini, Giuseppe
    Perdichizzi, Antonio
    ES2008: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2009, : 569 - 576
  • [9] A holistic framework for the optimal design and operation of electricity, heating, cooling and hydrogen technologies in buildings
    Olympios, Andreas, V
    Kourougianni, Fanourios
    Arsalis, Alexandros
    Papanastasiou, Panos
    Pantaleo, Antonio M.
    Markides, Christos N.
    Georghiou, George E.
    APPLIED ENERGY, 2024, 370
  • [10] Design of a recyclic solar air heater for low temperature regions utilizing integrated wavy corrugated thermal energy storage systems
    Nagale, Vaibhav Dilip
    Singh, Satyender
    Kumar, Sanjay
    APPLIED THERMAL ENGINEERING, 2023, 227