No Difference in 10-year Clinical or Radiographic Outcomes Between Kinematic and Mechanical Alignment in TKA: A Randomized Trial

被引:0
|
作者
Gibbons, John P. [1 ]
Zeng, Nina [1 ]
Bayan, Ali [1 ]
Walker, Matthew L. [1 ]
Farrington, Bill [1 ]
Young, Simon W. [1 ,2 ]
机构
[1] North Shore Hosp, Dept Orthopaed Surg, 124 Shakespeare Rd,Private Bag 93-503, Auckland 0740, New Zealand
[2] Univ Auckland, Dept Surg, Auckland, New Zealand
关键词
TOTAL KNEE ARTHROPLASTY; JOINT; REPLACEMENT; REVISION; SYSTEM; RISK;
D O I
10.1097/CORR.0000000000003193
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThere is continuing debate about the ideal philosophy for component alignment in TKA. However, there are limited long-term functional and radiographic data on randomized comparisons of kinematic alignment versus mechanical alignment. Questions/purposesWe present the 10-year follow-up findings of a single-center, multisurgeon randomized controlled trial (RCT) comparing these two alignment philosophies in terms of the following questions: (1) Is there a difference in PROM scores? (2) Is there a difference in survivorship free from revision or reoperation for any cause? (3) Is there a difference in survivorship free from radiographic loosening? MethodsNinety-nine patients undergoing primary TKA for osteoarthritis were randomized to either the mechanical alignment (n = 50) or kinematic alignment (n = 49) group. Eligibility for the study was patients undergoing unilateral TKA for osteoarthritis who were suitable for a cruciate-retaining TKA and could undergo MRI. Patients who had previous osteotomy, coronal alignment > 15 degrees from neutral, a fixed flexion deformity > 15 degrees, or instability whereby constrained components were being considered were excluded. Computer navigation was used in the mechanical alignment group, and patient-specific cutting blocks were used in the kinematic alignment group. At 10 years, 86% (43) of the patients in the mechanical alignment group and 80% (39) in the kinematic alignment group were available for follow-up performed as a per-protocol analysis. The PROMs that we assessed included the Knee Society Score, Oxford Knee Score, WOMAC, Forgotten Joint Score, and EuroQol 5-Dimension score. Kaplan-Meier analysis was used to assess survivorship free from reoperation (any reason) and revision (change or addition of any component). A single blinded observer assessed radiographs for signs of aseptic loosening (as defined by the presence of progressive radiolucent lines in two or more zones), which was reported as survivorship free from loosening. ResultsAt 10 years, there was no difference in any PROM score measured between the groups. Ten-year survivorship free from revision (components removed or added) likewise did not differ between the groups (96% [95% CI 91% to 99%] for the mechanical alignment group and 91% [95% CI 83% to 99%] for the kinematic alignment group; p = 0.38). There were two revisions in the mechanical alignment group (periprosthetic fracture, deep infection) and four in the kinematic alignment group (two secondary patella resurfacings, two deep infections). There was no statistically significant difference in reoperations for any cause between the two groups. There was no difference with regard to survivorship free from loosening on radiographic review (chi 2 = 1.3; p = 0.52) (progressive radiolucent lines seen at 10 years were 0% for mechanical alignment and 3% for kinematic alignment). ConclusionLike the 2-year and 5-year outcomes previously reported, 10-year follow-up for this RCT demonstrated no functional or radiographic difference in outcomes between mechanical alignment and kinematic alignment TKA. Anticipated functional benefits of kinematic alignment were not demonstrated, and revision-free survivorship at 10 years did not differ between the two groups. Given the unknown long-term impact of kinematic alignment with regard to implant position (especially tibial component varus), we must conclude that mechanical alignment remains the reference standard for TKA. We could not demonstrate any advantage to kinematic alignment at 10-year follow-up. Level of EvidenceLevel I, therapeutic study.
引用
收藏
页码:140 / 149
页数:10
相关论文
共 50 条
  • [2] No Difference in 5-year Clinical or Radiographic Outcomes Between Kinematic and Mechanical Alignment in TKA: A Randomized Controlled Trial
    Young, Simon W.
    Sullivan, Niall P. T.
    Walker, Matthew L.
    Holland, Sherina
    Bayan, Ali
    Farrington, Bill
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2020, 478 (06) : 1271 - 1279
  • [3] CORR Insights®: No Difference in 5-year Clinical or Radiographic Outcomes Between Kinematic and Mechanical Alignment in TKA: A Randomized Controlled Trial
    Heesterbeek, Petra J. C.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2020, 478 (06) : 1280 - 1282
  • [4] The Chitranjan S. Ranawat Award No Difference in 2-year Functional Outcomes Using Kinematic versus Mechanical Alignment in TKA: A Randomized Controlled Clinical Trial
    Young, Simon W.
    Walker, Matthew L.
    Bayan, Ali
    Briant-Evans, Toby
    Pavlou, Paul
    Farrington, Bill
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (01) : 9 - 20
  • [5] Comparison of clinical and biomechanical outcomes between the kinematic and mechanical alignment methods in total knee arthroplasty: Protocol for a multicenter randomized controlled trial
    Takashima, Yoshinori
    Matsumoto, Tomoyuki
    Takayama, Koji
    Nakano, Naoki
    Kuroda, Yuichi
    Tsubosaka, Masanori
    Kamenaga, Tomoyuki
    Kikuchi, Kenichi
    Fujita, Masahiro
    Ikuta, Kemmei
    Anjiki, Kensuke
    Hayashi, Shinya
    Hashimoto, Shingo
    Maeda, Toshihisa
    Inokuchi, Takao
    Toda, Mitsunori
    Chin, Takaaki
    Kuroda, Ryosuke
    CONTEMPORARY CLINICAL TRIALS COMMUNICATIONS, 2021, 22
  • [6] No Benefit of Computer-assisted TKA: 10-year Results of a Prospective Randomized Study
    Ollivier, Matthieu
    Parratte, Sebastien
    Lino, Ludovic
    Flecher, Xavier
    Pesenti, Sebastien
    Argenson, Jean-Noel
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (01) : 126 - 134
  • [7] Clinical outcomes of kinematic alignment versus mechanical alignment in total knee arthroplasty: a systematic review
    Roussot, Mark Anthony
    Vles, Georges Frederic
    Oussedik, Sam
    EFORT OPEN REVIEWS, 2020, 5 (08) : 486 - 497
  • [8] Alignment accuracy and functional outcomes between hand-held navigation and conventional instruments in TKA: a randomized controlled trial
    Narkbunnam, Rapeepat
    Pornrattanamaneewong, Chaturong
    Ruangsomboon, Pakpoom
    Chareancholvanich, Keerati
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [9] No difference in mechanical alignment and femoral component placement between patient-specific instrumentation and conventional instrumentation in TKA
    Fu, Huichao
    Wang, Jiaxing
    Zhou, Shenyuan
    Cheng, Tao
    Zhang, Wen
    Wang, Qi
    Zhang, Xianlong
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (11) : 3288 - 3295
  • [10] Alignment accuracy and functional outcomes between hand-held navigation and conventional instruments in TKA: a randomized controlled trial
    Rapeepat Narkbunnam
    Chaturong Pornrattanamaneewong
    Pakpoom Ruangsomboon
    Keerati Chareancholvanich
    BMC Musculoskeletal Disorders, 23