Effect of Clinical Experience on Accuracy of Implant Placement Using Dynamic Navigation and Static Guidance: An In Vitro Study

被引:0
作者
Fang, Qiao [1 ,3 ]
Lozada, Jaime [1 ]
Kan, Joseph [1 ]
Al-Ardah, Aladdin [1 ]
Li, Yiming [2 ]
机构
[1] Loma Linda Univ, Sch Dent, Adv Educ Program Implant Dent, Loma Linda, CA 92350 USA
[2] Loma Linda Univ, Sch Dent, Ctr Dent Res, Loma Linda, CA USA
[3] Univ Illinois, Coll Dent, Dept Restorat Dent, Chicago, IL 60607 USA
关键词
dynamic navigation; static guidance; in vitro study; accuracy of implant placement; dental implant experience; surgical site; COMPUTER-TECHNOLOGY APPLICATIONS; GUIDED SURGERY; DENTAL IMPLANTS; DENTISTRY;
D O I
10.1563/aaid-joi-D-23-00181
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to investigate the accuracy of implants placed by clinicians with varying dental implant experience using dynamic navigation (DN) and static guidance (SG). Sixty identical custom-made, drillable maxillary models were fabricated, missing the right central incisor (#8) and left first molar (#14) with simulated gingival tissue. Models planned with a DN system and guided surgery software were randomly allocated to an experienced clinician, an inexperienced clinician, and a nonexperienced clinician. The accuracy of implant placement was evaluated by overlaying the preoperative virtual surgical plan with the postoperative cone beam computerized tomography scan. Deviations between the placed and planned implants were quantified using a mathematical algorithm. Independent-sample t tests revealed significant differences (p < .001) in angular deviation but not in coronal and apical deviations when comparing DN with SG for all 3 clinicians. One-way analysis of variance and Tukey post hoc test found no significant differences between clinicians of varying dental implant experience in DN and SG groups. The study concluded that the level of dental implant experience and surgical site do not significantly impact the accuracy of implant placement when either DN or SG is used, and DN produced less angular deviation in comparison with SG. This finding suggests DN could benefit clinical settings, particularly for less experienced clinicians.
引用
收藏
页码:626 / 635
页数:10
相关论文
共 31 条
  • [1] In Vivo Tooth-Supported Implant Surgical Guides Fabricated With Desktop Stereolithographic Printers: Fully Guided Surgery Is More Accurate Than Partially Guided Surgery
    Bencharit, Sompop
    Staffen, Adam
    Yeung, Matthew
    Whitley, Daniel, III
    Laskin, Daniel M.
    Deeb, George R.
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (07) : 1431 - 1439
  • [2] Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study
    Beretta, Mario
    Poli, Pier Paolo
    Maiorana, Carlo
    [J]. JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2014, 44 (04) : 184 - 193
  • [3] Implant Placement Accuracy Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Lank, Kathryn
    Ryan, James
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 92 - 99
  • [4] Static or Dynamic Navigation for Implant Placement-Choosing the Method of Guidance
    Block, Michael S.
    Emery, Robert W.
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 74 (02) : 269 - 277
  • [5] Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies
    Bover-Ramos, Fernando
    Vina-Almunia, Jose
    Cervera-Ballester, Juan
    Penarrocha-Diago, Miguel
    Garcia-Mira, Berta
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 101 - 115
  • [6] Accuracy of image-guided implantology
    Brief, J
    Edinger, D
    Hassfeld, S
    Eggers, G
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) : 495 - 501
  • [7] Navigation surgery for dental implants: Assessment of accuracy of the image guided implantology system
    Casap, N
    Wexler, A
    Persky, N
    Schneider, A
    Lustmann, J
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (09) : 116 - 119
  • [8] Chiu WK, 2006, INT J ORAL MAX IMPL, V21, P465
  • [9] How Accurate Are Implant Surgical Guides Produced With Desktop Stereolithographic 3-Dimentional Printers?
    Deeb, George R.
    Allen, Riley K.
    Hall, V. Patrick
    Whitley, Daniel, III
    Laskin, Daniel M.
    Bencharit, Sompop
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (12) : 2559.e1 - 2559.e8
  • [10] Exploring training dental implant placement using computer-guided implant navigation system for predoctoral students: A pilot study
    Deeb, Janina Golob
    Bencharit, Sompop
    Carrico, Caroline K.
    Lukic, Marija
    Hawkins, Daniel
    Rener-Sitar, Ksenija
    Deeb, George R.
    [J]. EUROPEAN JOURNAL OF DENTAL EDUCATION, 2019, 23 (04) : 415 - 423