Dosimetric investigation of multi-parametric 4D-MRI for radiotherapy in liver cancer

被引:0
|
作者
Sha Li [1 ]
Xianggao Zhu [2 ]
Haonan Xiao [2 ]
Weiwei Liu [3 ]
Yibao Zhang [4 ]
Jing Cai [2 ]
Tian Li [1 ]
Yanye Lu [2 ]
机构
[1] Peking University Health Science Center,Institute of Medical Technology
[2] Peking University Cancer Hospital & Institute,Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education / Beijing), Department of Radiation Oncology
[3] Beijing Cancer Hospital & Institute,Department of Health Technology and Informatics
[4] Department of Radiotherapy,National Biomedical Imaging Center
[5] Affiliated Cancer Hospital of Inner Mongolia Medical University & Peking University Cancer Hospital (Inner Mongolia Campus); Key Laboratoy of Radiation Physics and Biology of Inner Mongolia Medical University,undefined
[6] The Hong Kong Polytechnic University,undefined
[7] Peking University,undefined
关键词
Multi-parametric 4D-MRI; Liver cancer; Radiotherapy; Target contouring; Plan; DDEM;
D O I
10.1186/s13014-025-02600-3
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] Improved vessel-tissue contrast and image quality in 3D radial sampling-based 4D-MRI
    Deng, Zixin
    Yang, Wensha
    Pang, Jianing
    Bi, Xiaoming
    Tuli, Richard
    Li, Debiao
    Fan, Zhaoyang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (06): : 250 - 257
  • [32] Comparative study of sub-second temporal resolution 4D-MRI and 4D-CT for target motion assessment in a phantom model
    Wang, Tianyuan
    Sofue, Keitaro
    Shimada, Ryuji
    Ishihara, Takeaki
    Yada, Ryuichi
    Miyamoto, Masanori
    Sasaki, Ryohei
    Murakami, Takamichi
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [33] Simultaneous acquisition of orthogonal plane cine imaging and isotropic 4D-MRI using super-resolution
    Mickevicius, Nikolai J.
    Paulson, Eric S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 136 : 121 - 129
  • [34] Dosimetric evaluation of an automatic segmentation tool of pelvic structures from MRI images for prostate cancer radiotherapy
    Pasquier, D.
    Lacornerie, T.
    Betrouni, N.
    Vermandel, M.
    Rousseau, J.
    Lartigau, E.
    CANCER RADIOTHERAPIE, 2008, 12 (05): : 323 - 330
  • [35] Characterization of cervical lymph-nodes using a multi-parametric and multi-modal approach for an early prediction of tumor response to chemo-radiotherapy
    Scalco, Elisa
    Marzi, Simona
    Sanguineti, Giuseppe
    Vidiri, Antonello
    Rizzo, Giovanna
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1672 - 1680
  • [36] A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion
    Yang, Y. X.
    Teo, S. -K.
    Van Reeth, E.
    Tan, C. H.
    Tham, I. W. K.
    Poh, C. L.
    MEDICAL PHYSICS, 2015, 42 (08) : 4484 - 4496
  • [37] Stable and efficient retrospective 4D-MRI using non-uniformly distributed quasi-random numbers
    Breuer, Kathrin
    Meyer, Cord B.
    Breuer, Felix A.
    Richter, Anne
    Exner, Florian
    Weng, Andreas M.
    Stroehle, Serge
    Polat, Buelent
    Jakob, Peter M.
    Sauer, Otto A.
    Flentje, Michael
    Weick, Stefan
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (07):
  • [38] Clinical and dosimetric aspects in concurrent radiotherapy with CDK4/6 inhibitors in breast cancer
    Rebegea, Laura Florentina
    Ilie, Ana Maria
    Anghel, Rodica
    Lungu, Mihaela
    Dumitru, Mihaela Emilia
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S632 - S633
  • [39] Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom
    Yue, Yong
    Fan, Zhaoyang
    Yang, Wensha
    Pang, Jianing
    Deng, Zixin
    McKenzie, Elizabeth
    Tuli, Richard
    Wallace, Robert
    Li, Debiao
    Fraass, Benedick
    MEDICAL PHYSICS, 2015, 42 (10) : 5787 - 5797
  • [40] Dosimetric comparison of liver tumour radiotherapy in all respiratory phases and in one phase using 4DCT
    Gabrys, Dorota
    Kulik, Roland
    Trela, Krystyna
    Slosarek, Krzysztof
    RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) : 360 - 364