A Comparative Analysis of the Accuracy of Crown Fabricated from Conventional Wax Patterns and CAD/CAM Technology - Milling and 3D Printing

被引:1
作者
Kumar, M. V. Sunil [1 ]
Kumar, Rajesh [1 ]
Saini, Ravindher Singh [2 ]
Vyas, Rajesh [2 ]
Vaddamanu, Sunil Kumar [2 ]
机构
[1] Maharaj Vinayak Global Univ, Jaipur Dent Coll, Dept Prosthodont, Jaipur, Rajasthan, India
[2] King Khalid Univ, Coll Appl Med Sci, Dept Allied Dent Hlth Sci, Abha, Saudi Arabia
关键词
3D-printing; accuracy; CAD/CAM; gold crowns; internal fit; marginal gap; milling; silicone replica technique; wax patterns; FIT;
D O I
10.4103/jpbs.jpbs_985_24
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background:Digital manufacturing techniques such as milling (subtractive) and 3D printing (additive) are increasingly used in dental restorations. These technologies promise enhanced precision and efficiency compared to traditional methods. However, the accuracy of marginal and internal fits of crowns produced by these techniques remains under-explored.Objective:To evaluate and compare the marginal and internal fit of dental crowns fabricated using two digital manufacturing techniques: Milling (subtractive) and 3D printing (additive).Materials and Methods:A maxillary first molar was replicated to create seven representative dies for each technique. Crowns were fabricated using both milling and 3D printing methods. The fit of the crowns was assessed using the silicone replica technique, measuring occlusal, axial, marginal gaps, and internal fit.Results:3D printing demonstrated the most precise fit across all measurement points, with significantly smaller discrepancies compared to milling. The two-way ANOVA analysis confirmed a significant effect of the fabrication method on marginal and internal gaps, highlighting the superior performance of 3D printing. However, the silicone replica technique revealed fewer significant differences between the two methods.Conclusion:3D printing offers enhanced precision and consistency in crown fabrication compared to milling. Despite promising results, further research is necessary to confirm the long-term efficacy and cost-effectiveness of these techniques. Future studies should focus on larger clinical cohorts to validate these findings.
引用
收藏
页码:S3821 / S3823
页数:3
相关论文
共 10 条
[1]   Fit of zirconia fixed partial denture: a systematic review [J].
Abduo, J. ;
Lyons, K. ;
Swain, M. .
JOURNAL OF ORAL REHABILITATION, 2010, 37 (11) :866-876
[2]   A model-based adaptive controller for chatter mitigation and productivity enhancement in CNC milling machines [J].
Bort, Carlos Maximiliano Giorgio ;
Leonesio, Marco ;
Bosetti, Paolo .
ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2016, 40 :34-43
[3]   The Accuracy of Fit of Crowns Made From Wax Patterns Produced Conventionally (Hand Formed) and Via CAD/CAM Technology [J].
Fathi, Hawa M. ;
Al-Masoody, Azal H. ;
El-Ghezawi, Narjes ;
Johnson, Anthony .
EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2016, 24 (01) :P10-P17
[4]   In vitro evaluation of the internal and marginal misfit of CAD/CAM zirconia copings [J].
Lins, Leonardo ;
Bemfica, Vinicius ;
Queiroz, Celso ;
Canabarro, Antonio .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (03) :205-211
[5]  
Pettenò D, 2000, INT J PROSTHODONT, V13, P405
[6]   The Application of Rapid Prototyping in Prosthodontics [J].
Sun, Jian ;
Zhang, Fu-Qiang .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (08) :641-644
[7]   In vitro Results of Scanning Technique on Assessing Cement Thickness and Interfacial Nanoleakage of Luted CAD/CAM-Fabricated Fiber Posts [J].
Vaddamanu, Sunil Kumar ;
Vyas, Rajesh ;
Bavabeedu, Shashit Shetty ;
Arora, Suraj ;
Badiyani, Bhumika Kamal ;
Kumar, Amit .
JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05) :676-678
[8]   The future of dental devices is digital [J].
van Noort, Richard .
DENTAL MATERIALS, 2012, 28 (01) :3-12
[9]  
Vojdani M, 2013, J Dent (Shiraz), V14, P118
[10]   FIT OF CROWN WAX PATTERNS AFTER REMOVAL FROM THE DIE [J].
ZELTSER, C ;
LEWINSTEIN, I ;
GRAJOWER, R .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (03) :344-346