A critical review of in-duct ultraviolet germicidal irradiation systems: Mechanisms, challenges, and future directions

被引:2
作者
Ye, Jinjun [1 ,2 ]
Ai, Zhengtao [1 ,2 ]
Liu, Fang [1 ,2 ]
Wargocki, Pawel [3 ]
机构
[1] Hunan Univ, Coll Civil Engn, Dept Bldg Environm & Energy, Changsha, Hunan, Peoples R China
[2] Hunan Univ, Natl Ctr Int Res Collaborat Bldg Safety & Environm, Changsha, Hunan, Peoples R China
[3] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Environm & Resource Engn, Kongens Lyngby, Denmark
关键词
In-duct UVGI system; Microbial contamination; Inactivation performance; Numerical research method; Review; COMPUTATIONAL FLUID-DYNAMICS; LIGHT-EMITTING-DIODES; RELATIVE-HUMIDITY; DISINFECTION PERFORMANCE; PRESSURE UV; PSEUDOMONAS-AERUGINOSA; LEGIONELLA-PNEUMOPHILA; INDUCED INACTIVATION; ESCHERICHIA-COLI; DARK REPAIR;
D O I
10.1016/j.psep.2025.106840
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ultraviolet germicidal irradiation (UVGI) is a well-established technology for mitigating microbial risks, with induct UVGI systems being a promising type that enables coexistence with occupants. However, there exists a disparity between the application demand and research advancement, which may be attributed to the misconceptions on in-duct UVGI systems and the shortage of strategies that significantly improve inactivation efficiency. This work systematically reviewed and analyzed the mechanisms and challenges (including existing misconceptions, factors affecting inactivation performance, and research methods) of in-duct UVGI systems. Furthermore, several future research directions were discussed, including optimizing the location of UVC lamps, developing multi-band synergistic strategies, assessing risks related to ozone and mercury exposure, refining research methods, and establishing experimental test databases. Finally, the necessity and feasibility of two perspectives were provided: 1) the development of anti-fouling materials applicable to lamps and duct walls; 2) the establishment of fault prognostic systems. In summary, the information provided here is expected to help improve the inactivation performance and system resilience.
引用
收藏
页数:18
相关论文
共 153 条
[1]   COVID-19 pandemic lesson learned- critical parameters and research needs for UVC inactivation of viral aerosols [J].
Abkar, Leili ;
Zimmermann, Karl ;
Dixit, Fuhar ;
Kheyrandish, Ataollah ;
Mohseni, Madjid .
JOURNAL OF HAZARDOUS MATERIALS ADVANCES, 2022, 8
[2]   The rise of research networks [J].
Adams, Jonathan .
NATURE, 2012, 490 (7420) :335-336
[3]  
AHAM, 2023, AHAM AC-5-2023 Revision 2.0
[4]   Tracer gas is a suitable surrogate of exhaled droplet nuclei for studying airborne transmission in the built environment [J].
Ai, Zhengtao ;
Mak, Cheuk Ming ;
Gao, Naiping ;
Niu, Jianlei .
BUILDING SIMULATION, 2020, 13 (03) :489-496
[5]   A unified view of base excision repair: Lesion-dependent protein complexes regulated by post-translational modification [J].
Almeida, Karen H. ;
Sobol, Robert W. .
DNA REPAIR, 2007, 6 (06) :695-711
[6]  
Alscher RG, 1997, PHYSIOL PLANTARUM, V100, P224, DOI 10.1034/j.1399-3054.1997.1000203.x
[7]  
[Anonymous], 2009, WHO Guidelines for Indoor Air Quality: Dampness and Mould
[8]  
[Anonymous], 2021, ASHRAE Position Document on Filtration and Air Cleaning
[9]  
[Anonymous], 2016, ASHRAE HDB HVAC SYST
[10]  
[Anonymous], 2017, Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size