Acurate Neo2 for valve-in-valve treatment of degenerated 3F Enable sutureless bioprosthetic valve in nonagenarian patient: a case report

被引:0
|
作者
Vecchia, Andres Agustin [1 ]
Migliaro, Giuseppe [2 ]
Cioffi, Paolo [1 ]
Calderone, Dario [3 ]
Verolino, Giuseppe [3 ]
机构
[1] Citta Alessandria Inst, Cardiac Cath Lab, Via Moccagatta 30, I-15121 Alessandria, Italy
[2] Unit Cardiovasc Sci, Campus Biomed Univ Rome, Via Alvaro Portillo 200, I-00128 Rome, Italy
[3] San Luca Hosp, Invas Cardiol IRCCS Ist Auxol Italiano, Piazzale Brescia 20, I-20148 Milan, Italy
关键词
3F Enable; Surgical sutureless valve; Valve-in-valve TAVI; Self-expandable valve; Aortic regurgitation; Structural valve deterioration; Case report; IMPLANTATION; REPLACEMENT; OUTCOMES;
D O I
10.1093/ehjcr/ytaf073
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Sutureless bioprosthetic valves (SBVs) are engineered to enable a less invasive surgical valve replacement procedure in patients at high surgical risk. Valve degeneration is a relatively common occurrence across all types of surgical valves, including SBVs. Valve-in-valve (ViV) procedures are increasingly becoming the preferred treatment for many cases of valve degeneration due to their minimally invasive nature and favourable long-term outcomes. However, the specific structural characteristics of SBVs present challenges for ViV procedures, and the evidence on this subject remains limited.Case summary A 91-year-old man was admitted to our hospital presenting with dyspnoea due to severe aortic regurgitation in a degenerated 3F Enable sutureless valve. Valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) was successfully performed using a self-expanding Acurate Neo2 valve, yielding good haemodynamic results without overt interaction between the prosthesis. A 6-month follow-up echocardiogram confirmed excellent valve performance.Discussion ViV-TAVI is a well-established treatment for bioprosthetic valve failure in high-risk patients. However, sutureless valve degeneration presents a challenging scenario for ViV procedures, with only a limited number of cases performed using the Acurate platform. In this case, we demonstrated the technical feasibility of ViV using the Acurate system in a less explored surgical sutureless bioprosthesis.
引用
收藏
页数:6
相关论文
共 27 条
  • [1] Sutureless 3f Enable valve implantation concomitant with mitral valve surgery
    Vola, Marco
    Ruggieri, Vito Giovanni
    Campisi, Salvatore
    Grinberg, Daniel
    Morel, Jerome
    Favre, Jean-Pierre
    Ayari, Iness
    Issaz, Karl
    Fuzellier, Jean-Francois
    Gerbay, Antoine
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (02) : 169 - 175
  • [2] Coronary access after ACURATE neo2 implantation for valve-in-valve TAVR: Insights from ex vivo simulations
    Khokhar, Arif A.
    Giannini, Francesco
    Zlahoda-Huzior, Adriana
    Mikhail, Ghada
    Dudek, Dariusz
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 100 (04) : 662 - 666
  • [3] Case Report: A case of transcatheter aortic valve replacement in a patient with a small aortic annulus using the Acurate Neo2
    Malik, Shahzil Abdur Rehman
    Ali, Jamshed
    Javed, Maleeha
    Hussain, Kamran
    Azeem, Navaira
    Rehman, Nasir
    Faheem, Osman
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2025, 12
  • [4] EchoNavigator®-guided transcatheter mitral valve-in-valve procedure to treat a degenerated radiolucent surgical bioprosthetic valve: a case report
    Ebrahimi, Ali J.
    Alkhawam, Mustafa
    Myla, Madhura
    Salama, Amr
    Ahmed, Mustafa, I
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2025, 9 (03)
  • [5] Sutureless 3F Enable Valve Replacement for Pure Aortic Regurgitation
    Vola, Marco
    Fuzellier, Jean-Francois
    Anselmi, Amedeo
    Campisi, Salvatore
    Haber, Benjamain
    Isaaz, Karl
    Gerbay, Antoine
    Ruggieri, Vito Giovanni
    JOURNAL OF CARDIAC SURGERY, 2015, 30 (11) : 796 - 800
  • [6] Sutureless Aortic Valve Replacement With the 3f Enable Aortic Bioprosthesis
    Martens, Sven
    Ploss, Anja
    Sirat, Sami
    Miskovic, Alexandra
    Moritz, Anton
    Doss, Mirko
    ANNALS OF THORACIC SURGERY, 2009, 87 (06): : 1914 - 1918
  • [7] ACURATE neo2 versus SAPIEN 3 Ultra for transcatheter aortic valve
    Pellegrini, Costanza
    Rheude, Tobias
    Renker, Matthias
    Wolf, Alexander
    Wambach, Jan Martin
    Alvarez-Covarrubias, Hector A.
    Doerr, Oliver
    Singh, Parminder
    Charitos, Efstratios, I
    Xhepa, Erion
    Joner, Michael
    Kim, Won-Keun
    EUROINTERVENTION, 2023, 18 (12) : 987 - +
  • [8] Repeated transcatheter aortic valve implantation for the treatment of a degenerated transcatheter aortic valve implantation valve (valve-in-valve technique): a case report
    Voudris, Vassileios
    Iakovou, Ioannis
    Kosmas, Ilias
    Sbarouni, Eftychia
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2020, 4 (06)
  • [9] Fluid Dynamic Investigation of the ATS 3F Enable Sutureless Heart Valve
    Stuehle, Sebastian
    Wendt, Daniel
    Hou, Guojun
    Wendt, Hermann
    Thielmann, Matthias
    Jakob, Heinz
    Kowalczyk, Wojciech
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2011, 6 (01) : 37 - 44
  • [10] Percutaneous Transcatheter Valve-in-Valve Implantation With the Balloon-Expandable Valve for the Treatment of a Dysfunctional Tricuspid Bioprosthetic Valve - A Pediatric Case Report
    Hanna, Baher Matta
    Rodes-Cabau, Josep
    Dahdah, Nagib
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (06): : 310 - 312