Waste heat recovery of a combined internal combustion engine and inverse brayton cycle for hydrogen and freshwater outputs: 4E optimization and comparison

被引:0
|
作者
Zoghi, Mohammad [1 ]
Hosseinzadeh, Nasser [1 ]
Gharaie, Saleh [1 ]
Zare, Ali [1 ]
机构
[1] Deakin Univ, Sch Engn, Geelong, Vic 3216, Australia
来源
ENERGY NEXUS | 2025年 / 17卷
关键词
Internal combustion engine; Inverse brayton cycle; Multi-generation; Performance comparison; 4E study; ORGANIC RANKINE-CYCLE; SYSTEM; ENERGY; ORC; PARAMETERS; SIMULATION; EXERGY;
D O I
10.1016/j.nexus.2024.100356
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In power plants, internal combustion engines (ICEs) continue to serve as a prevalent source of power generation. Despite advancements in ICE performance over the past decade, significant amounts of energy are still wasted through exhaust gases and jacket cooling water. In this study, advanced waste heat recovery technologies are explored to enhance the overall efficiency of ICE power plants. Initially, an inverse Brayton cycle (IBC) is employed for exhaust gas energy recovery in a 500 kW ICE. Subsequently, waste energy in the heat rejection stage of the IBC and the exhausted gas from the compressor is recovered using a thermoelectric generator (TEG) and an absorption chiller. Additionally, the extra electricity generated by the TEG is directed to a proton exchange membrane electrolyzer and a reverse osmosis desalination unit, producing hydrogen and potable water as additional outputs. Furthermore, energy from the jacket cooling water is recovered in a hot water unit. The 4E (energy, exergy, exergy-economic, and environmental) performance of the two configurations is compared by sensitivity analysis and design optimization. Exergy efficiency and unit cost of product (UCOP) are obtained as 36.09% and 58.303 $/GJ for the stand-alone engine. They are calculated at 39.62% and 64.553 $/GJ and 43.05% and 62.06 $/GJ for Configurations 1 and 2, respectively, in the optimum mode. In this case, Configuration 2 leads to the highest efficiency, and while the UCOP of Configuration 2 is better than that of Configuration 1, the stand-alone engine has the best value of UCOP. This suggests that converting a stand-alone engine to an integrated system with multiple useful outputs is a feasible and beneficial strategy for improving power plant efficiency and sustainability. Furthermore, in the optimum mode and for Configuration 2, improvements of 1.36% and 1.49% are reported for exergy efficiency and UCOP in comparison with the base case mode.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Comparison of working fluids and cycle optimization for heat recovery ORCs from large internal combustion engines
    Scaccabarozzi, Roberto
    Tavano, Michele
    Invernizzi, Costante Mario
    Martelli, Emanuele
    ENERGY, 2018, 158 : 396 - 416
  • [22] Dynamic model of supercritical Organic Rankine Cycle waste heat recovery system for internal combustion engine
    Jahedul Islam Chowdhury
    Bao Kha Nguyen
    David Thornhill
    International Journal of Automotive Technology, 2017, 18 : 589 - 601
  • [23] A combined thermodynamic cycle based on methanol dissociation for IC (internal combustion) engine exhaust heat recovery
    Fu, Jianqin
    Liu, Jingping
    Xu, Zhengxin
    Ren, Chengqin
    Deng, Banglin
    ENERGY, 2013, 55 : 778 - 786
  • [24] A comparative study between a Rankine cycle and a novel intra-cycle based waste heat recovery concepts applied to an internal combustion engine
    Morgan, Robert
    Dong, Guangyu
    Panesar, Angad
    Heikal, Morgan
    APPLIED ENERGY, 2016, 174 : 108 - 117
  • [25] Exergy, Economic, and Life-Cycle Assessment of ORC System for Waste Heat Recovery in a Natural Gas Internal Combustion Engine
    Valencia Ochoa, Guillermo
    Cardenas Gutierrez, Javier
    Duarte Forero, Jorge
    RESOURCES-BASEL, 2020, 9 (01):
  • [26] Thermodynamic analysis and performance optimization of the supercritical carbon dioxide Brayton cycle combined with the Kalina cycle for waste heat recovery from a marine low-speed diesel engine
    Feng, Yongming
    Du, Zhiqiang
    Shreka, Majed
    Zhu, Yuanqing
    Zhou, Song
    Zhang, Wenping
    ENERGY CONVERSION AND MANAGEMENT, 2020, 206
  • [27] Comprehensive 4E analysis and optimization of a hybrid solar-biogas gas turbine system Coupled with a geothermal flash cycle for hydrogen and freshwater production
    Mei, Bing
    Li, Raozhi
    Wang, Yan
    Qing, Yahong
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 105 : 56 - 79
  • [28] Waste heat recovery of a combined regenerative gas turbine - recompression supercritical CO2 Brayton cycle driven by a hybrid solar-biomass heat source for multi-generation purpose: 4E analysis and parametric study
    Cao, Yan
    Habibi, Hamed
    Zoghi, Mohammad
    Raise, Amir
    ENERGY, 2021, 236
  • [29] Transient Optimal Control of a Transcritical Organic Rankine Cycle for Waste Heat Recovery of Internal Combustion Engine Based on Deep Reinforcement Learning
    Wang X.
    Chen J.
    Shu G.
    Tian H.
    Cai J.
    Wang R.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (11): : 4169 - 4177
  • [30] Numerical Optimization of an Ejector for Waste Heat Recovery Used to Cool Down the Intake Air in an Internal Combustion Engine
    Galindo, Jose
    Gil, Antonio
    Dolz, Vicente
    Ponce-Mora, Alberto
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2020, 12 (05)