Femoral Neck Fractures: A New Risk Assessment Method Using CT Hounsfield Measurement

被引:0
作者
Emir, Sevde Nur [1 ]
Bulut, Safiye Sanem Dereli [1 ]
机构
[1] Univ Hlth Sci Turkey, Umraniye Training & Res Hosp, Dept Radiol, Istanbul, Turkiye
来源
TURK OSTEOPOROZ DERGISI-TURKISH JOURNAL OF OSTEOPOROSIS | 2024年 / 30卷 / 03期
关键词
Bone density; computed tomography; femur; Hounsfield unit; osteoporosis; COMPUTED-TOMOGRAPHY; TRABECULAR ATTENUATION; OSTEOPOROSIS; CONTRAST; DXA;
D O I
10.4274/tod.galenos.2024.77527
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Hip fractures, which are a serious consequence of osteoporosis, lead to a decrease in life expectancy. Computed tomography (CT) Hounsfield unit (HU) measurements have been clinically utilized to assess fracture risk. Materials and Methods: This retrospective study, conducted between 2020-2023, analyzed 99 patients with femoral neck fractures and 62 controls who underwent pelvic CT. Two radiologists conducted bone density measurements using CT, with specific measurements at the femoral head, fracture level, and lesser trochanter. Statistical analyses, including Mann-Whitney U tests, Wilcoxon tests, chi-square tests, ROC curve analysis, and logistic regression analysis, were performed using SPSS version 28.0. Results: The study revealed significant differences in bone density measurements between the fractured and control groups. Proximal, middle, and distal values demonstrated significant differences in distinguishing between patients with and without fractures. The distal measurement was the most effective measure, with an area under the curve of 0.918. Conclusion: This study emphasizes the potential of CT HU measurements for predicting femur fracture risk, particularly the distal measurement at the minor trochanter level. Further research with larger samples and comparisons with other methods, such as dual X-ray absorptiometry or quantitative CT, are needed to validate these findings and their clinical significance.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 50 条
  • [31] Estimation of Bone Mineral Density in the Femoral Neck and Lumbar Spine using Texture Analysis of Chest and Pelvis Computed Tomography Hounsfield Unit
    Min, Young-kyung
    Lee, Dong-Ha
    Yoo, Jae-Heung
    Park, Man-Jun
    Huh, Jung-Wook
    Kim, MinWoo
    CURRENT MEDICAL IMAGING, 2023, 19 (10) : 1186 - 1195
  • [32] Quantitative assessment of orbital fractures in Asian patients: CT measurement of orbital volume
    Sugiura, Kensuke
    Yamada, Harumoto
    Okumoto, Takayuki
    Inoue, Yoshikazu
    Onishi, Satoko
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (12) : 1944 - 1947
  • [33] Femoral neck width genetic risk score is a novel independent risk factor for hip fractures
    Tobias, Jonathan H.
    Nethander, Maria
    Faber, Benjamin G.
    Heppenstall, Sophie, V
    Ebsim, Raja
    Cootes, Tim
    Lindner, Claudia
    Saunders, Fiona R.
    Gregory, Jenny S.
    Aspden, Richard M.
    Harvey, Nicholas C.
    Kemp, John P.
    Frysz, Monika
    Ohlsson, Claes
    JOURNAL OF BONE AND MINERAL RESEARCH, 2024, 39 (03) : 241 - 251
  • [34] Vertebral fractures in osteoporosis -: A new method for clinical assessment
    Genant, HK
    Li, J
    Wu, CY
    Shepherd, JA
    JOURNAL OF CLINICAL DENSITOMETRY, 2000, 3 (03) : 281 - 290
  • [35] A three-dimensional measurement based on CT for the posterior tilt with ideal inter-and intra-observer reliability in non-displaced femoral neck fractures
    Wu, Shenghui
    Wang, Wei
    Zhang, Binbin
    Zhang, Haowei
    Xu, Xinsheng
    Li, Guangyi
    Shi, Huipeng
    Mei, Jiong
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (16) : 1854 - 1861
  • [36] Absolute Fracture Risk Assessment Using Lumbar Spine and Femoral Neck Bone Density Measurements: Derivation and Validation of a Hybrid System
    Leslie, William D.
    Lix, Lisa M.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2011, 26 (03) : 460 - 467
  • [37] Opportunistic Osteoporosis Assessment and Fracture Risk Determination Using Cancellous Density Measurement in Hounsfield Units of Native Lumbar Computed Tomography Images-A Comparative Study with Conventional Bone Density Evaluation
    Andresen, Julian Ramin
    Schroeder, Guido
    Haider, Thomas
    Andresen, Reimer
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)
  • [38] Site-Dependent Reference Point Microindentation Complements Clinical Measures for Improved Fracture Risk Assessment at the Human Femoral Neck
    Jenkins, Thomas
    Coutts, Louise V.
    D'Angelo, Stefania
    Dunlop, Douglas G.
    Oreffo, Richard O. C.
    Cooper, Cyrus
    Harvey, Nicholas C.
    Thurner, Phillipp J.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2016, 31 (01) : 196 - 203
  • [39] Comparison of two tools for the measurement of interfragmentary movement in femoral neck fractures stabilised by cannulated screws
    Nabhani, Farhad
    Bradley, Edward J.
    Hodgson, Simon
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2010, 26 (06) : 610 - 615
  • [40] Potential pathogenic mechanism for stress fractures of the bowed femoral shaft in the elderly: Mechanical analysis by the CT-based finite element method
    Oh, Yoto
    Wakabayashi, Yoshiaki
    Kurosa, Yoshiro
    Fujita, Koji
    Okawa, Atsushi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (11): : 1764 - 1771