Precise Acetabular Prosthesis Positioning Using a Novel Robot-Assisted Total Hip Arthroplasty System: A Multicenter, Randomized Controlled Trial

被引:0
|
作者
Geng, Xiao [1 ,2 ]
Dong, Ziyang [1 ,2 ]
Li, Yang [1 ,2 ]
Zhao, Minwei [1 ,2 ]
Liu, Yanqing [1 ,2 ]
Li, Zijian [1 ,2 ]
Cai, Hong [1 ,2 ]
Zhang, Ming [3 ]
Yan, Xinfeng [3 ]
Sun, Zhiwen [4 ]
Lv, Xin [4 ]
Guo, Feng [4 ]
Li, Feng [1 ,2 ]
Tian, Hua [1 ,2 ]
机构
[1] Peking Univ Third Hosp, Dept Orthopaed, Beijing, Peoples R China
[2] Engn Res Ctr Bone & Joint Precis Med, Beijing, Peoples R China
[3] Shandong First Med Univ, Affiliated Hosp 1, Shandong Prov Qianfoshan Hosp, Dept Orthopaed, Jinan, Peoples R China
[4] Chifeng Municipal Hosp, Dept Orthopaed, Chifeng, Peoples R China
关键词
acetabular prosthesis positioning; anteversion angle; inclination angle; robotic surgery; total hip arthroplasty; DISLOCATION; ARTHRITIS;
D O I
10.1111/os.14277
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Total hip arthroplasty (THA) is currently one of the most effective treatment methods for end-stage hip joint disease, and its long-term effectiveness largely depends on the accurate placement of the acetabular prosthesis. In conventional surgery, the placement of the acetabular prosthesis mainly relies on the surgeon's clinical experience and surgical techniques. To further improve the accuracy of prosthesis placement, a new robotic system for THA is designed. The purpose of this study is to verify the effectiveness and safety of THA assisted by this robotic system. Method A multicenter, prospective, randomized controlled, superiority study design was adopted with statistical methods of t test and Chi-squared test. Participants undergoing primary THA have been enrolled in three centers of joint surgery in China since July 17, 2023. Robotic THA was operated in the experimental group, and conventional instruments were used in the control group. The primary outcome is the proportion of anteversion and inclination angles in the safe zone. The secondary outcomes include operation time, WOMAC score, Harris score, SF-36 health questionnaire, dislocation rate of hip joint, and rates of adverse events and serious adverse events. Results A total of 138 patients were included in this study. The proportion of both anteversion and inclination angles in the safe zone was 92.2% in the experimental group and 50.8% in the control group, with significant difference (p < 0.01). The average operation time in the experimental group and control group was 116.4 and 80.5 min respectively, with significant difference (p < 0.01). There was no significant difference in WOMAC score, Harris score, and SF-36 between the two groups (6 +/- 2) weeks after operation (p > 0.05). The dislocation rate of hip joint in the experimental group and control group were 3.0% and 1.5%, respectively, without significant difference (p > 0.05). The rate of adverse events and severe adverse events in the experimental group and control group also showed no significant difference (p > 0.05). No adverse events or serious adverse events were judged to be "definitely related" to the experimental instruments. Conclusion Robotic THA could prolong the operation time within an acceptable range, but more precise acetabular prosthesis positioning could be obtained when compared with conventional surgery. Besides, no significant difference was found in function scores, dislocation rate or other adverse events, which indicates that this new robot system shows both good effectiveness and safety in THA.
引用
收藏
页码:141 / 150
页数:10
相关论文
共 50 条
  • [41] Accuracy of acetabular cup positioning in robotic-assisted total hip arthroplasty: a CT-based evaluation
    Singh, Ashish
    Kumar, Purushotam
    Kalyan, Kanukuntla
    Gundalli, Akash Chandrashekar
    Mane, Sudhir Shankar
    Swarnkar, Himanshu
    Singh, Lavanya
    SICOT-J, 2024, 10
  • [42] A New Dressing System for Wound in Enhanced-Recovery Total Hip Arthroplasty: A Randomized and Controlled Trial
    Lei, Primary Hip Pengfei
    Zhong, Da
    Wu, Honghao
    Gao, Fawei
    Qi, Jun
    Li, Zhigang
    Lai, Lili
    Su, Shilong
    JOURNAL OF ARTHROPLASTY, 2023, 38 (08) : 1565 - 1570
  • [43] Does Robotic-Assisted Computer Navigation Affect Acetabular Cup Positioning in Total Hip Arthroplasty in the Obese Patient? A Comparison Study
    Gupta, Asheesh
    Redmond, John M.
    Hammarstedt, Jon E.
    Petrakos, Alexandra E.
    Vemula, S. Pavan
    Domb, Benjamin G.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12) : 2204 - 2207
  • [44] Comparison of Intravenous Acetaminophen and Intravenous Patient-Controlled Analgesia Fentanyl after Total Hip Arthroplasty: A Multicenter Randomized Controlled Trial
    Sakai, Yoshinori
    Imai, Norio
    Miyasaka, Dai
    Suzuki, Hayato
    Horigome, Yoji
    Takahashi, Yasuhito
    Kawashima, Hiroyuki
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)
  • [45] The LANCET robotic system can improve surgical efficiency in total hip arthroplasty: A prospective randomized, multicenter, parallel-controlled clinical trial
    Xu, Zhihong
    Chai, Senlin
    Chen, Dongyang
    Wang, Weijun
    Dai, Jin
    Zhang, Xiaofeng
    Qin, Jianghui
    Song, Kai
    Li, Xinhua
    Han, Jing
    Chang, Qing
    Zhang, Miaofeng
    Xue, Chenxi
    Lu, Jun
    Wu, Lidong
    Yao, Yunfeng
    Li, Lan
    Jiang, Qing
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2024, 45 : 247 - 255
  • [46] Errors in femoral anteversion, femoral offset, and vertical offset following robot-assisted total hip arthroplasty
    Hsieh, Chih-Ming
    Howell, Stephen M.
    Hull, Maury L.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (04)
  • [47] Supercapsular percutaneously-assisted total hip (SuperPath) versus mini-incision posterolateral total hip arthroplasty for hip osteoarthritis: a prospective randomized controlled trial
    Meng, Weikun
    Gao, Liang
    Huang, Zhong
    Wang, Haoyang
    Wang, Duan
    Luo, Zeyu
    Bai, Yang
    Wang, Guanglin
    Zhou, Zongke
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (05)
  • [48] Capsular Management in Direct Anterior Total Hip Arthroplasty: A Randomized, Single-Blind, Controlled Trial
    Schwartz, Andrew M.
    Goel, Rahul K.
    Sweeney, Aidan P.
    Bradbury, Thomas L., Jr.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (08) : 2836 - 2842
  • [49] Posterior Hip Precautions Do Not Impact Early Recovery in Total Hip Arthroplasty: A Multicenter, Randomized, Controlled Study
    Dietz, Matthew J.
    Klein, Adam E.
    Lindsey, Brock A.
    Duncan, Stephen T.
    Eicher, Jennifer M.
    Gillig, Jonathan D.
    Smith, Brett R.
    Steele, G. Daxton
    JOURNAL OF ARTHROPLASTY, 2019, 34 (07) : S221 - +
  • [50] Robot-assisted primary cementless total hip arthroplasty using surface registration techniques: a short-term clinical report
    Nobuo Nakamura
    Nobuhiko Sugano
    Takashi Nishii
    Hidenobu Miki
    Akihiro Kakimoto
    Mitsuyoshi Yamamura
    International Journal of Computer Assisted Radiology and Surgery, 2009, 4 : 157 - 162