Human body convective heat transfer coefficient under non-stationary turbulent wind

被引:0
作者
Zhou, Siqi [1 ]
Yu, Yichen [1 ]
Niu, Jianlei [1 ]
Kwok, Kenny C. S. [2 ]
Chauhan, Kapil [2 ]
Tse, Kam Tim [3 ]
Xu, Xinzi [1 ]
Wong, Sam Ho Yan [3 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Kowloon, Hong Kong, Peoples R China
[2] Univ Sydney, Wind Waves & Water, Sch Civil Engn, Sydney, Australia
[3] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Kowloon, Clear Water Bay, Hong Kong, Peoples R China
关键词
Convective heat transfer; Non-stationary wind; Pedestrian-level wind turbulence; Outdoor thermal comfort; Wind tunnel; Thermal manikin; OUTDOOR THERMAL COMFORT; AIR-FLOW; HOT WEATHER; LENGTH SCALE; CYLINDER; TEMPERATURE; MODEL; ENVIRONMENTS; EXTREMES; SPEED;
D O I
10.1016/j.buildenv.2025.112632
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent decades, extensive research has focused on the role of dynamic airflow in improving thermal comfort from both physiological and psychological perspectives. However, the specific mechanism by which dynamic airflow affects convective heat transfer from the human body remains unclear. This study utilizes an active shutter and a passive grid to simulate non-stationary turbulent flows in a wind tunnel, and employs a thermal manikin to determine the convective heat transfer coefficient (hc) over the human body. Considering the physical constraints posed by a wind tunnel, the simulated wind conditions were considered to be reasonably representative of pedestrian-level wind environment. The findings indicate that while high-frequency turbulence intensity significantly increases hc, hc does not change notably with fluctuation amplitude in the low-frequency range. In outdoor settings, turbulence intensity can be overestimated by more than half if the synoptic trend is not removed. Therefore, detrending dynamic flow is critical for accurately calculating turbulence intensity; otherwise, the whole body's hc could be overestimated by up to 40 %. Furthermore, when the integral length scale is smaller than half the manikin's characteristic length, the impact on hc is limited. A reduction in wavelength of low-frequency fluctuation component in dynamic flow contributes to enhancing hc, while no more than 4 % in typical outdoor pedestrian-level wind conditions. To improve the accuracy of the predicted hcin prototype pedestrian-level urban environment, an equivalent wind speed which accounts for the effects of turbulence has been proposed to adjust the wind speed input in current thermal comfort models.
引用
收藏
页数:14
相关论文
共 56 条
  • [1] HEAT-TRANSFER DISTRIBUTION AROUND A CYLINDER IN PULSATING CROSS-FLOW
    ANDRAKA, CE
    DILLER, TE
    [J]. JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1985, 107 (04): : 976 - 982
  • [2] Azzam A., 2018, On the Generation of Unsteady Mean and Turbulent Flows in a Wind Tunnel Using an Active Grid
  • [3] On modelling of typhoon-induced non-stationary wind speed for tall buildings
    Chen, J
    Xu, YL
    [J]. STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2004, 13 (02) : 145 - 163
  • [4] Exploring 167 years of vulnerability: An examination of extreme heat events in Australia 1844-2010
    Coates, Lucinda
    Haynes, Katharine
    O'Brien, James
    McAneney, John
    de Oliveira, Felipe Dimer
    [J]. ENVIRONMENTAL SCIENCE & POLICY, 2014, 42 : 33 - 44
  • [5] Convective and radiative heat transfer coefficients for individual human body segments
    deDear, RJ
    Arens, E
    Hui, Z
    Oguro, M
    [J]. INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1997, 40 (03) : 141 - 156
  • [6] Ebi KL, 2021, LANCET, V398, P698, DOI 10.1016/S0140-6736(21)01208-3
  • [7] Gagge A.P., 1971, ASHRAE Transactions, V77, P247
  • [8] Hinze J.O., 1959, TURBULENCE INTRO ITS
  • [9] Perceptible airflow fluctuation frequency and human thermal response
    Huang, Li
    Ouyang, Qin
    Zhu, Yingxin
    [J]. BUILDING AND ENVIRONMENT, 2012, 54 : 14 - 19
  • [10] Simultaneous environmental parameter monitoring and human subject survey regarding outdoor thermal comfort and its modelling
    Huang, Taiyang
    Li, Jianong
    Xie, Yongxin
    Niu, Jianlei
    Mak, Cheuk Ming
    [J]. BUILDING AND ENVIRONMENT, 2017, 125 : 502 - 514