Diagnostic accuracy of point-of-care ultrasound of the posterior fatpad in elbow fractures

被引:0
|
作者
Haak, Svenja L. [1 ,2 ]
van der Veen, Thea [1 ]
Stolmeijer, Renate [2 ]
Boendermaker, Annemieke E. [3 ]
van der Kolk, Brigitta Y. M. [4 ]
ter Maaten, Jan C. [2 ]
Ter Avest, Ewoud [2 ,5 ]
Lameijer, Heleen [1 ]
机构
[1] Med Ctr Leeuwarden, Dept Emergency Med, Leeuwarden, Netherlands
[2] Univ Med Ctr Groningen, Dept Acute Care, Groningen, Netherlands
[3] Tjongerschans Hosp Heerenveen, Dept Emergency Med, Heerenveen, Friesland, Netherlands
[4] Isala, Dept Emergency Med, Zwolle, Overijssel, Netherlands
[5] Londons Air Ambulance & Barts Hlth NHS Trust, Royal London Hosp, London, England
关键词
fractures and dislocations; ultrasonography; trauma; extremity; COMPUTED-TOMOGRAPHY; TRAUMA; ULTRASONOGRAPHY; CHILDREN; ADULTS;
D O I
10.1136/emermed-2024-214448
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Point-of-care ultrasound (POCUS) can potentially be used in the triage of patients with elbow injuries. However, the diagnostic accuracy of POCUS performed by non-radiologists for the exclusion of elbow fractures is yet unknown. This study aimed to investigate the diagnostic potential of POCUS of the posterior fatpad performed by non-radiologists in the workup of adult patients presenting with elbow injuries.Methods A multicentre, prospective cohort study was conducted between January 2021 and August 2022 in four EDs to determine the diagnostic accuracy of an elevated posterior fatpad on POCUS to demonstrate or exclude an elbow fracture in patients presenting with elbow injuries to the ED. The study population consisted of a convenience sample. In patients >= 16 years of age with an elbow injury for which an X-ray was ordered, POCUS was performed by emergency physicians trained in ultrasound. POCUS (index test) results were compared with X-ray outcomes (reference standard) to determine the diagnostic accuracy of POCUS.Results A total of 215 patients were included, 143 (67%) of whom had a fracture confirmed on X-ray. POCUS was positive based on a visualised elevated posterior fatpad in 127 (59%) patients. An elevated posterior fatpad on POCUS had a sensitivity of 91% (95% CIs 85% to 95%), a specificity of 93% (95% CI 85% to 98%), a negative likelihood ratio of 0.10 (95% CI 0.06 to 0.16) and a positive likelihood ratio of 13.09 (95% CI 5.61 to 30.54) for the presence of an elbow fracture. Post hoc review of the images by expert sonographers improved sensitivity to 96% (95% CI 91% to 99%).Conclusion POCUS of the posterior fatpad is a promising adjunct to physical examination to determine the need for further diagnostic studies in the triage of patients with elbow injuries. Sensitivity after a limited training is high, but not perfect, and can likely further be improved with additional training.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Point-of-Care Ultrasound for the Trauma Anesthesiologist
    Heinz, Eric R.
    Vincent, Anita
    CURRENT ANESTHESIOLOGY REPORTS, 2022, 12 (02) : 217 - 225
  • [22] Point-of-Care Thoracic Ultrasound in Trauma
    Cook, Justin O.
    CURRENT RESPIRATORY MEDICINE REVIEWS, 2015, 11 (01) : 8 - 16
  • [23] Point-of-Care Ultrasound for the Detection of Traumatic Intracranial Hemorrhage in Infants A Pilot Study
    McCormick, Taylor
    Chilstrom, Mikaela
    Childs, Jeannine
    McGarry, Ryan
    Seif, Dina
    Mailhot, Thomas
    Perera, Phillips
    Kang, Tarina
    Claudius, Ilene
    PEDIATRIC EMERGENCY CARE, 2017, 33 (01) : 18 - 20
  • [24] Diagnostic accuracy of point-of-care ultrasound for shock: a systematic review and meta-analysis
    Yoshida, Takuo
    Yoshida, Takuya
    Noma, Hisashi
    Nomura, Takeshi
    Suzuki, Akihiro
    Mihara, Takahiro
    CRITICAL CARE, 2023, 27 (01)
  • [25] Diagnostic accuracy of point-of-care ultrasound for pulmonary tuberculosis: A systematic review
    Bigio, Jacob
    Kohli, Mikashmi
    Klinton, Joel Shyam
    MacLean, Emily
    Gore, Genevieve
    Small, Peter M.
    Ruhwald, Morten
    Weber, Stefan Fabian
    Jha, Saurabh
    Pai, Madhukar
    PLOS ONE, 2021, 16 (05):
  • [26] Evidence base for point-of-care ultrasound (POCUS) for diagnosis of skull fractures in children: a systematic review and meta-analysis
    Alexandridis, Georgios
    Verschuuren, Eva W.
    Rosendaal, Arthur, V
    Kanhai, Danny A.
    EMERGENCY MEDICINE JOURNAL, 2022, 39 (01) : 30 - 36
  • [27] Diagnostic accuracy of point-of-care ultrasound (PoCUS) for the diagnosis of hip effusion in the pediatric emergency department
    Katz-Dana, Hadas
    Stackievicz, Rudica
    Dana, Elad
    Friedman, Nir
    Lackner, Gali
    Rosenbloom, Ehud
    Shles, Ayelet
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2024, : 875 - 882
  • [28] Diagnostic accuracy of point-of-care ultrasound for catheter-related thrombosis in children
    Simon Li
    Cicero T. Silva
    Adele R. Brudnicki
    Kenneth E. Baker
    Joana A. Tala
    Matthew G. Pinto
    Lee A. Polikoff
    Li Qin
    E. Vincent S. Faustino
    Pediatric Radiology, 2016, 46 : 219 - 228
  • [29] A Systemic Review on the Diagnostic Accuracy of Point-of-Care Ultrasound in Patients With Undifferentiated Shock in the Emergency Department
    Berg, Ingvar
    Walpot, Kris
    Lamprecht, Hein
    Valois, Maxime
    Lanctot, Jean-Francois
    Srour, Nadim
    van den Brand, Crispijn
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [30] Utility of tele-guidance for point-of-care ultrasound: a single center prospective diagnostic study
    Cal, Eric M.
    Gunnell, Elias
    Olinger, Kristen
    Benefield, Thad
    Nelson, Jacob
    Maggioncalda, Elise
    McGinty, Katrina
    JOURNAL OF ULTRASOUND, 2024, 27 (03) : 519 - 525