The development of patient-specific 3D anatomical models in minimally invasive parathyroidectomy

被引:0
|
作者
Haq, Zahra J. [1 ]
Ahmed, Ahmed [2 ]
Abdelsalam, Alaa [2 ]
Chegini, Soudeh [3 ]
Kurzawinski, Tom R. [2 ]
Morley, Simon [4 ]
Mcgurk, Mark [5 ]
Abdel-Aziz, Tarek [2 ]
机构
[1] UCL, Med Sch, London, England
[2] Univ Coll London Hosp, Dept Endocrine Surg, London, England
[3] Univ Coll London Hosp, Oral & Maxillofacial Surg, London, England
[4] Univ Coll London Hosp, Dept Imaging, London, England
[5] Univ Coll London Hosp, Oral Maxillofacial Head & Neck Surg, London, England
来源
FRONTIERS IN ENDOCRINOLOGY | 2024年 / 15卷
关键词
primary hyper parathyroidism; parathyroid; -; adenoma; parathyrodectomy; minimally invasive surgery; HoloLens; 2; three-dimensional mode; PRIMARY HYPERPARATHYROIDISM;
D O I
10.3389/fendo.2024.1514451
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Surgery is the preferred treatment for primary hyperparathyroidism. Minimally invasive parathyroidectomy is only feasible with accurate preoperative localisation. Virtual 3D anatomical models can be constructed from patient-specific CT scans using segmentation software.Methods We aimed to create virtual 3D models from 4D-CT scans of parathyroid tumours using segmentation technology. We designed a small pilot study to assess the utility of 3D models within surgical practice. We assessed surgeon, trainee and patients' opinion and satisfaction with the models. The NASA TLX survey was the primary data collection toolResults Creation of novel 3D models was achieved, these featured a 360-degree axis of rotation and transparency mode to assist in surgical planning. Models were used intraoperatively with the HoloLens 2 headset to locate parathyroid tumours real time before surgery. Total mean workloads for surgery planning when averaged revealed a decrease workload (39.45 vs 27.45) points with adjunctive use of models (p=0.002). Mental demand showed the greatest decrease in mean workload out of all the 6 subscales tested for in the NASA TLX (210.3 vs 136.7) points. Patient satisfaction score was statistically significant for the difference before and after seeing the 3D model regarding anatomical location (p=<= 0.001),Conclusion In this work, we developed patient-specific virtual 3D anatomical models of parathyroid tumours for use in surgery using novel techniques, previously never applied to parathyroidectomy. Our initial success in model construction and subsequent opinion of surgeons, trainees and patients contributes to the developing body of literature in favour of virtual modelling for parathyroidectomy.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Minimally Invasive Parathyroidectomy under Local Anesthesia: Patient Satisfaction and Overall Outcome
    Chau, Jason K. M.
    Hoy, Monica
    Tsui, Ban
    Harris, Jeffrey R.
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2010, 39 (04): : 361 - 369
  • [2] A rural perspective on minimally invasive parathyroidectomy: optimal preoperative imaging and patient outcomes
    Binks, Matthew
    Burrows, Denbigh
    Littlejohn, David
    ANZ JOURNAL OF SURGERY, 2019, 89 (1-2) : 43 - 47
  • [3] Brachial plexus block for minimally invasive parathyroidectomy: report of 3 cases
    Gil, S.
    Pretel, M.
    Madrazo, M.
    Redondo, J.
    Sarabia, R.
    Bernal, G.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2008, 55 (08): : 508 - 512
  • [4] Preoperative simulation of minimally invasive aortic valve replacement using patient-specific replica
    Murakami, Takashi
    Yasumizu, Daisuke
    Hosono, Mitsuharu
    Sakaguchi, Masanori
    Takahashi, Yosuke
    Shibata, Toshihiko
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2017, 65 (05) : 302 - 303
  • [5] Patient-Specific Biomechanical Modeling for Guidance During Minimally-Invasive Hepatic Surgery
    Rosalie Plantefève
    Igor Peterlik
    Nazim Haouchine
    Stéphane Cotin
    Annals of Biomedical Engineering, 2016, 44 : 139 - 153
  • [6] Preoperative simulation of minimally invasive aortic valve replacement using patient-specific replica
    Takashi Murakami
    Daisuke Yasumizu
    Mitsuharu Hosono
    Masanori Sakaguchi
    Yosuke Takahashi
    Toshihiko Shibata
    General Thoracic and Cardiovascular Surgery, 2017, 65 : 302 - 303
  • [7] On the feasibility of minimally invasive Le Fort I with patient-specific implants: Proof of concept
    Hernandez-Alfaro, Federico
    Saavedra, Oscar
    Duran-Valles, Francesc
    Valls-Ontanon, Adaia
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2024, 125 (03)
  • [8] Patient-Specific Biomechanical Modeling for Guidance During Minimally-Invasive Hepatic Surgery
    Plantefeve, Rosalie
    Peterlik, Igor
    Haouchine, Nazim
    Cotin, Stephane
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (01) : 139 - 153
  • [9] Vitamin D3 Deficiency is Associated with Late-Onset Hypocalcemia After Minimally Invasive Parathyroidectomy in a Vitamin D Borderline Area
    Lang, Brian Hung-Hin
    Lo, Chung-Yau
    WORLD JOURNAL OF SURGERY, 2010, 34 (06) : 1350 - 1355
  • [10] 3D digital anatomical measurements for clinical application of minimally invasive lumbar foraminal surgery in adolescents aged 12-21 years
    Gao, Mingjie
    Shi, Guopeng
    He, Zhuoqun
    Bao, Malian
    Zhang, Kai
    Li, Jing
    Li, Feng
    Zhu, Yong
    Li, Xiaohe
    Wang, Haiyan
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2025, 257