A robust planning approach for respiratory motion in accelerated partial breast irradiation using volumetric modulated arc therapy

被引:0
|
作者
Yamauchi, Ryohei [1 ]
Tomita, Fumihiro [1 ]
Ishikura, Satoshi [1 ]
机构
[1] St Lukes Int Hosp, Dept Radiat Oncol, 9-1 Akashi Cho Chuo Ku, Tokyo 1048560, Japan
关键词
breast cancer; accelerated partial breast irradiation; intensity modulated radiation therapy; respiratory motion; RADIOTHERAPY; IMRT; OPTIMIZATION; WOMEN; VMAT;
D O I
10.1093/jrr/rraf011
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Accelerated partial breast irradiation (APBI) is an alternative treatment for early-stage breast cancer. This study aimed to evaluate the effectiveness of the virtual bolus (VB) method and robust planning against respiratory motion in volumetric modulated arc therapy (VMAT)-APBI. VMAT plans were generated with 30 Gy in 5 fractions for 16 patients. Four treatment plans were developed and compared: a standard optimization (SO) plan without robust methods, a pseudo-skin flash strategy using a 5 mm VB (with densities of 0.4 and 1.0 g/cm3, VB04 and VB10), and a robust optimization (RO) plan to minimize penalties in worst-case scenarios. The isocenter was shifted 1-5 mm in each translational direction in robust analysis, and perturbed dose calculations were performed. All dose constraints for the target in SO and VB plans were within acceptable limits, but the dose evaluation volume V95% in the RO plan was lower than in other plans (P < 0.05). The clinical target volume V95% of the RO plan was significantly higher than in VB04 and VB10 (P < 0.05). The RO plan showed the best performance for organs at risk, followed by SO and VB plans, which resulted in higher doses. The RO plan exhibited the smallest change (+/- 2%) in dose distribution due to respiratory motion. By contrast, the SO plan lacked robustness owing to absence of sufficient fluence in the air surrounding the planning target volume outside of the skin surface. The RO plan offers superior target coverage, maximum dose, and robustness compared to SO and VB methods.
引用
收藏
页码:185 / 195
页数:11
相关论文
共 50 条
  • [41] Larynx motion considerations in partial larynx volumetric modulated arc therapy for early glottic cancer
    Bahig, Houda
    Nguyen-Tan, Phuc Felix
    Filion, Edith
    Roberge, David
    Thanomsack, Pensavan
    de Guise, Jacques
    Blais, Danis
    Doucet, Robert
    Letourneau-Guillon, Laurent
    Lambert, Louise
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (05) : 666 - 673
  • [42] Inverse planning for four-dimensional (4D) volumetric modulated arc therapy
    Ma, Yunzhi
    Chang, Daniel
    Keall, Paul
    Xie, Yiaoqin
    Park, Jae-yoon
    Suh, Tae-Suk
    Xing, Lei
    MEDICAL PHYSICS, 2010, 37 (11) : 5627 - 5633
  • [43] Dosimetric Effect on Breast Cancer Patients Treated with Volumetric-Modulated Arc Therapy: Single Institutional Experience
    Hashem, Rania
    Mulla, Zaheeda
    Ghassal, Nour
    Bokhary, Ayman
    Howladar, Fatimah
    Fallatah, Kholoud
    Iskandarani, Omar
    Attar, Mohammad
    Ujaimi, Reem
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2021, 10 (02): : 55 - 62
  • [44] Target tracking using DMLC for volumetric modulated arc therapy: A simulation study
    Sun, Baozhou
    Rangaraj, Dharanipathy
    Papiez, Lech
    Oddiraju, Swetha
    Yang, Deshan
    Li, H. Harold
    MEDICAL PHYSICS, 2010, 37 (12) : 6116 - 6124
  • [45] Automatic interactive optimization for volumetric modulated arc therapy planning
    Tol, Jim P.
    Dahele, Max
    Peltola, Jarkko
    Nord, Janne
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    RADIATION ONCOLOGY, 2015, 10
  • [46] Automated volumetric modulated arc therapy planning for whole pelvic prostate radiotherapy
    Buschmann, Martin
    Sharfo, Abdul Wahab M.
    Penninkhof, Joan
    Seppenwoolde, Yvette
    Goldner, Gregor
    Georg, Dietmar
    Breedveld, Sebastiaan
    Heijmen, Ben J. M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (04) : 333 - 342
  • [47] Treatment Planning for Volumetric-Modulated Arc Therapy: Model and Heuristic Algorithms
    Song, Jie
    Shi, Zhongshun
    Sun, Bofei
    Shi, Leyuan
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2015, 12 (01) : 116 - 126
  • [48] Breast Volume Is a Predictor of Higher Heart Dose in Whole-Breast Supine Free-Breathing Volumetric-Modulated Arc Therapy Planning
    Alaimo, Rita
    Ippolito, Edy
    Falconi, Rita
    Perrone Congedi, Francesca
    Sciommari, Cecilia
    Silipigni, Sonia
    Pellegrini, Roberto
    Carnevale, Alessia
    Greco, Carlo
    Fiore, Michele
    D'Angelillo, Rolando M.
    Ramella, Sara
    CURRENT ONCOLOGY, 2023, 30 (12) : 10530 - 10538
  • [49] Reducing the Risk of Secondary Lung Cancer in Treatment Planning of Accelerated Partial Breast Irradiation
    Hoekstra, Nienke
    Habraken, Steven
    Swaak-Kragten, Annemarie
    Breedveld, Sebastiaan
    Pignol, Jean-Philippe
    Hoogeman, Mischa
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [50] Comparison of volumetric modulated arc therapy and intensity-modulated radiotherapy for left-sided whole-breast irradiation using automated planning
    L. Redapi
    L. Rossi
    L. Marrazzo
    J. J. Penninkhof
    S. Pallotta
    B. Heijmen
    Strahlentherapie und Onkologie, 2022, 198 : 236 - 246