Validity of Wearable Inertial Sensors for Gait Analysis: A Systematic Review

被引:1
|
作者
Prisco, Giuseppe [1 ]
Pirozzi, Maria Agnese [2 ]
Santone, Antonella [1 ]
Esposito, Fabrizio [2 ]
Cesarelli, Mario [3 ]
Amato, Francesco [4 ]
Donisi, Leandro [2 ]
机构
[1] Univ Molise, Dept Med & Hlth Sci, I-86100 Campobasso, Italy
[2] Univ Campania Luigi Vanvitelli, Dept Adv Med & Surg Sci, I-80138 Naples, Italy
[3] Univ Sannio, Dept Engn, I-82100 Benevento, Italy
[4] Univ Naples Federico II, Dept Informat Technol & Elect Engn, I-80125 Naples, Italy
关键词
agreement; biomechanics; gait analysis; inertial measurement units; wearable sensors; VALIDATION; ACCELEROMETER; PARAMETERS; KINEMATICS; GYROSCOPE; EVENTS; MOTION;
D O I
10.3390/diagnostics15010036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Gait analysis, traditionally performed with lab-based optical motion capture systems, offers high accuracy but is costly and impractical for real-world use. Wearable technologies, especially inertial measurement units (IMUs), enable portable and accessible assessments outside the lab, though challenges with sensor placement, signal selection, and algorithm design can affect accuracy. This systematic review aims to bridge the benchmarking gap between IMU-based and traditional systems, validating the use of wearable inertial systems for gait analysis. Methods: This review examined English studies between 2012 and 2023, retrieved from the Scopus database, comparing wearable sensors to optical motion capture systems, focusing on IMU body placement, gait parameters, and validation metrics. Exclusion criteria for the search included conference papers, reviews, unavailable papers, studies without wearable inertial sensors for gait analysis, and those not involving agreement studies or optical motion capture systems. Results: From an initial pool of 479 articles, 32 were selected for full-text screening. Among them, the lower body resulted in the most common site for single IMU placement (in 22 studies), while the most frequently used multi-sensor configuration involved IMU positioning on the lower back, shanks, feet, and thighs (10 studies). Regarding gait parameters, 11 studies out of the 32 included studies focused on spatial-temporal parameters, 12 on joint kinematics, 2 on gait events, and the remainder on a combination of parameters. In terms of validation metrics, 24 studies employed correlation coefficients as the primary measure, while 7 studies used a combination of error metrics, correlation coefficients, and Bland-Altman analysis. Validation metrics revealed that IMUs exhibited good to moderate agreement with optical motion capture systems for kinematic measures. In contrast, spatiotemporal parameters demonstrated greater variability, with agreement ranging from moderate to poor. Conclusions: This review highlighted the transformative potential of wearable IMUs in advancing gait analysis beyond the constraints of traditional laboratory-based systems.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Technical challenges using magneto-inertial sensors for gait analysis
    Gastaldi, L.
    Rosso, V.
    Gabola, V.
    Agostini, V.
    Frutos, M. M. Lovagnini
    Knaflitz, M.
    Takeda, R.
    Tadano, S.
    2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 274 - 279
  • [42] Freezing of gait and fall detection in Parkinson's disease using wearable sensors: a systematic review
    Silva de Lima, Ana Ligia
    Evers, Luc J. W.
    Hahn, Tim
    Bataille, Lauren
    Hamilton, Jamie L.
    Little, Max A.
    Okuma, Yasuyuki
    Bloem, Bastiaan R.
    Faber, Marjan J.
    JOURNAL OF NEUROLOGY, 2017, 264 (08) : 1642 - 1654
  • [43] Reliability of gait analysis using wearable sensors in patients with knee osteoarthritis
    Kobsar, Dylan
    Osis, Sean T.
    Phinyomark, Angkoon
    Boyd, Jeffrey E.
    Ferber, Reed
    JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 3977 - 3982
  • [44] Gait Analysis Using Floor Markers and Inertial Sensors
    Tri Nhut Do
    Suh, Young Soo
    SENSORS, 2012, 12 (02) : 1594 - 1611
  • [45] A Comparative Evaluation of Inertial Sensors for Gait and Jump Analysis
    Andrenacci, Isaia
    Boccaccini, Riccardo
    Bolzoni, Alice
    Colavolpe, Giulio
    Costantino, Cosimo
    Federico, Michelangelo
    Ugolini, Alessandro
    Vannucci, Armando
    SENSORS, 2021, 21 (18)
  • [46] Gait Analysis Using Wearable Sensors
    Bhosale, Tanmav
    Kudale, Hemant
    Kumthekar, Varun
    Garude, Shreyash
    Dhumal, Prasad
    2015 INTERNATIONAL CONFERENCE ON ENERGY SYSTEMS AND APPLICATIONS, 2015, : 267 - 269
  • [47] Three Dimensional Gait Analysis Using Wearable Acceleration and Gyro Sensors Based on Quaternion Calculations
    Tadano, Shigeru
    Takeda, Ryo
    Miyagawa, Hiroaki
    SENSORS, 2013, 13 (07): : 9321 - 9343
  • [48] Mobile inertial sensor based gait analysis: Validity and reliability of spatiotemporal gait characteristics in healthy seniors
    Donath, Lars
    Faude, Oliver
    Lichtenstein, Eric
    Pagenstert, Geert
    Nuesch, Corina
    Mundermann, Annegret
    GAIT & POSTURE, 2016, 49 : 371 - 374
  • [49] Review wearable sensing system for gait recognition
    Yang, Gelan
    Tan, Wei
    Jin, Huixia
    Zhao, Tuo
    Tu, Li
    CLUSTER COMPUTING-THE JOURNAL OF NETWORKS SOFTWARE TOOLS AND APPLICATIONS, 2019, 22 (02): : S3021 - S3029
  • [50] Validity Evaluation of an Inertial Measurement Unit (IMU) in Gait Analysis Using Statistical Parametric Mapping (SPM)
    Park, Sangheon
    Yoon, Sukhoon
    SENSORS, 2021, 21 (11)