Validity of Wearable Inertial Sensors for Gait Analysis: A Systematic Review

被引:1
|
作者
Prisco, Giuseppe [1 ]
Pirozzi, Maria Agnese [2 ]
Santone, Antonella [1 ]
Esposito, Fabrizio [2 ]
Cesarelli, Mario [3 ]
Amato, Francesco [4 ]
Donisi, Leandro [2 ]
机构
[1] Univ Molise, Dept Med & Hlth Sci, I-86100 Campobasso, Italy
[2] Univ Campania Luigi Vanvitelli, Dept Adv Med & Surg Sci, I-80138 Naples, Italy
[3] Univ Sannio, Dept Engn, I-82100 Benevento, Italy
[4] Univ Naples Federico II, Dept Informat Technol & Elect Engn, I-80125 Naples, Italy
关键词
agreement; biomechanics; gait analysis; inertial measurement units; wearable sensors; VALIDATION; ACCELEROMETER; PARAMETERS; KINEMATICS; GYROSCOPE; EVENTS; MOTION;
D O I
10.3390/diagnostics15010036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Gait analysis, traditionally performed with lab-based optical motion capture systems, offers high accuracy but is costly and impractical for real-world use. Wearable technologies, especially inertial measurement units (IMUs), enable portable and accessible assessments outside the lab, though challenges with sensor placement, signal selection, and algorithm design can affect accuracy. This systematic review aims to bridge the benchmarking gap between IMU-based and traditional systems, validating the use of wearable inertial systems for gait analysis. Methods: This review examined English studies between 2012 and 2023, retrieved from the Scopus database, comparing wearable sensors to optical motion capture systems, focusing on IMU body placement, gait parameters, and validation metrics. Exclusion criteria for the search included conference papers, reviews, unavailable papers, studies without wearable inertial sensors for gait analysis, and those not involving agreement studies or optical motion capture systems. Results: From an initial pool of 479 articles, 32 were selected for full-text screening. Among them, the lower body resulted in the most common site for single IMU placement (in 22 studies), while the most frequently used multi-sensor configuration involved IMU positioning on the lower back, shanks, feet, and thighs (10 studies). Regarding gait parameters, 11 studies out of the 32 included studies focused on spatial-temporal parameters, 12 on joint kinematics, 2 on gait events, and the remainder on a combination of parameters. In terms of validation metrics, 24 studies employed correlation coefficients as the primary measure, while 7 studies used a combination of error metrics, correlation coefficients, and Bland-Altman analysis. Validation metrics revealed that IMUs exhibited good to moderate agreement with optical motion capture systems for kinematic measures. In contrast, spatiotemporal parameters demonstrated greater variability, with agreement ranging from moderate to poor. Conclusions: This review highlighted the transformative potential of wearable IMUs in advancing gait analysis beyond the constraints of traditional laboratory-based systems.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Inertial sensors versus standard systems in gait analysis: a systematic review and meta-analysis
    Petraglia, Federica
    Scarcella, Luca
    Pedrazzi, Giuseppe
    Brancato, Luigi
    Puers, Robert
    Costantino, Cosimo
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2019, 55 (02) : 265 - 280
  • [32] Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review
    Camomilla, Valentina
    Bergamini, Elena
    Fantozzi, Silvia
    Vannozzi, Giuseppe
    SENSORS, 2018, 18 (03)
  • [33] Inertial Sensors to Assess Gait Quality in Patients with Neurological Disorders: A Systematic Review of Technical and Analytical Challenges
    Vienne, Alienor
    Barrois, Remi P.
    Buffat, Stephane
    Ricard, Damien
    Vidal, Pierre-Paul
    FRONTIERS IN PSYCHOLOGY, 2017, 8
  • [34] Ambulatory Human Gait Phase Detection Using Wearable Inertial Sensors and Hidden Markov Model
    Liu, Long
    Wang, Huihui
    Li, Haorui
    Liu, Jiayi
    Qiu, Sen
    Zhao, Hongyu
    Guo, Xiangyang
    SENSORS, 2021, 21 (04) : 1 - 24
  • [35] A dataset for wearable sensors validation in gait analysis
    Pierleoni, Paola
    Pinti, Federica
    Belli, Alberto
    Palma, Lorenzo
    DATA IN BRIEF, 2020, 31
  • [36] Wearable inertial sensors provide reliable biomarkers of disease severity in multiple sclerosis: A systematic review and meta-analysis
    Vienne-Jumeau, Alienor
    Quijoux, Flavien
    Vidal, Pierre-Paul
    Ricard, Damien
    ANNALS OF PHYSICAL AND REHABILITATION MEDICINE, 2020, 63 (02) : 138 - 147
  • [37] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    SENSORS, 2018, 18 (03):
  • [38] Validity and reliability of inertial measurement units on gait, static balance and functional mobility performance among community-dwelling older adults: a systematic review and meta-analysis
    Yine, Lulu
    Xu, Xin
    Wang, Ruiyan
    Li, Feifei
    Wang, Yushan
    Wang, Lin
    EFORT OPEN REVIEWS, 2025, 10 (04) : 172 - 185
  • [39] Analysing Gait Patterns in Degenerative Lumbar Spine Disease Using Inertial Wearable Sensors: An Observational Study
    Natarajan, Pragadesh
    Fonseka, R. Dineth
    Sy, Luke Wincent
    Maharaj, Monish Movin
    Mobbs, Ralph Jasper
    WORLD NEUROSURGERY, 2022, 163 : E501 - E515
  • [40] Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
    Walmsley, Corrin P.
    Williams, Sian A.
    Grisbrook, Tiffany
    Elliott, Catherine
    Imms, Christine
    Campbell, Amity
    SPORTS MEDICINE-OPEN, 2018, 4