Effect of Rib Stiffeners on End-Plate Connections of Concrete-Filled Steel Tubular (CFST) Columns and I-Section Beams

被引:0
作者
Azimi, Aryan [1 ]
Ozakgul, Kadir [2 ]
机构
[1] Istanbul Tech Univ, Grad Sch, TR-34469 Maslak, Turkiye
[2] Istanbul Tech Univ, Dept Civil Engn, TR-34469 Istanbul, Turkiye
关键词
Concrete-filled steel tube (CFST); Through bolt; Bolted connection; Rib stiffener; Finite element (FE) analysis; EXPERIMENTAL BEHAVIOR; MOMENT CONNECTIONS; SEISMIC PERFORMANCE; STUB COLUMNS; CFT COLUMNS; JOINTS; DESIGN; TUBES;
D O I
10.1007/s13369-024-09719-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aims to analytically investigate the effect of rib stiffeners on through-bolt end-plate connections of concrete-filled steel tubular (CFST) columns and I-section beams. For this, 3D finite element (FE) models of the CFST column-I beam connections were generated. The FE models were validated with test results of similar connections published previously in literature. To examine the influence of the rib stiffeners, FE models of the stiffened connections were created by adding rib stiffeners of different thicknesses, slopes, and steel quality to the validated FE models. FE analyses considering both material and geometrical nonlinearities were performed under cyclic loading. The results of the analysis showed that the ultimate strength of the CFST column-I beam connection was affected by the slope of the rib stiffener rather than its thickness, but was not affected by its material quality. Although the rib stiffeners significantly increased the ultimate strength, they were unable to prevent local buckling in the beams, and therefore, no significant improvement in the ductile behavior of the connections was achieved. Additionally, it was seen that the rib stiffeners enhanced equivalent plastic strain (PEEQ) and had the effect of reducing relaxation of through bolts.
引用
收藏
页数:23
相关论文
共 59 条
[31]   EXTENDED END-PLATE CONNECTIONS UNDER CYCLIC LOADING - BEHAVIOR AND DESIGN [J].
KOROL, RM ;
GHOBARAH, A ;
OSMAN, A .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1990, 16 (04) :253-280
[32]   Seismic design of rib-reinforced steel moment connections based on equivalent strut model [J].
Lee, CH .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (09) :1121-1129
[33]   Review on blind bolted connections to concrete-filled steel tubes [J].
Li, Y. L. ;
Chan, T. M. ;
Zhao, X. L. .
THIN-WALLED STRUCTURES, 2023, 183
[34]   Experimental and numerical research on seismic behavior of end-plate connection beam-column joints considering concrete floor effect [J].
Lu, Shengcan ;
Zhang, Jiong ;
Wang, Minrong ;
Chen, Huiquan .
STRUCTURES, 2024, 65
[35]   Lessons from damage to steel buildings during the Northridge earthquake [J].
Mahin, SA .
ENGINEERING STRUCTURES, 1998, 20 (4-6) :261-270
[36]  
Morino Shosuke., 2003, Earthquake Engineering and Engineering Seismology, V4, P51
[37]   Performance enhancement of eight bolt extended end-plate moment connections under simulated seismic loading [J].
Morrison, Machel ;
Quayyum, Shahriar ;
Hassan, Tasnim .
ENGINEERING STRUCTURES, 2017, 151 :444-458
[38]  
Murray TM., 2002, Design Guide Series 16: Flush and Extended Multiple-Row Moment End-Plate Connections
[39]  
Murray TM., 2004, Design Guide Series 4: Extended End-Plate Moment Connections
[40]  
Osman A. A., 2021, Journal of Engineering and Applied Science, V68, P1