Comparison of fit and trueness of single-unit and short-span fixed dental restorations fabricated by additive and subtractive manufacturing-A systematic review and meta-analysis

被引:0
作者
Nemeth, Anna [1 ,2 ]
Vitai, Viktoria [1 ,2 ]
Kelemen, Kata [1 ,2 ]
Teutsch, Brigitta [1 ,3 ,6 ]
Szabo, Bence [1 ]
Gerber, Gabor [1 ,2 ]
Varga, Gabor [1 ,4 ]
Fazekas, Reka [1 ,5 ]
Hegyi, Peter [1 ,6 ,7 ]
Borbely, Judit [1 ,2 ]
机构
[1] Semmelweis Univ, Ctr Translat Med, Budapest, Hungary
[2] Semmelweis Univ, Dept Prosthodont, Szentkiralyi Utca 47, H-1088 Budapest, Hungary
[3] Semmelweis Univ, Med Imaging Ctr, Dept Radiol, Budapest, Hungary
[4] Semmelweis Univ, Dept Oral Biol, Budapest, Hungary
[5] Semmelweis Univ, Dept Restorat Dent & Endodont, Budapest, Hungary
[6] Univ Pecs, Inst Translat Med, Med Sch, Pecs, Hungary
[7] Semmelweis Univ, Inst Pancreat Dis, Budapest, Hungary
关键词
3D printing; Additive manufacturing; Subtractive manufacturing; Internal fit; Marginal fit; Trueness; INTAGLIO SURFACE TRUENESS; COMPUTER-AIDED-DESIGN; INTERNAL FIT; MARGINAL FIT; PROVISIONAL CROWNS; 3-DIMENSIONAL EVALUATION; FRACTURE-RESISTANCE; DENTURE FRAMEWORKS; METAL; ZIRCONIA;
D O I
10.1016/j.jdent.2024.105527
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Numerous studies have been conducted on the adaptation of dental restorations fabricated by additive (AM) and subtractive manufacturing (SM); however, the results are conflicting. This systematic review and metaanalysis aimed to evaluate the fit and trueness of fixed restorations made by AM compared to SM. Data: Studies investigating internal fit, marginal fit, and trueness of fixed prostheses were involved. Sources: The protocol was registered in PROSPERO (registration number CRD42022323090). An electronic search was performed with a predefined search query across four medical databases on the 6th of September 2023. Study selection: A total of 57 eligible studies were included and sub-grouped by material type (metals, ceramics, acrylic resins, composites). The outcomes were specified as internal fit, marginal fit, and trueness expressed in micrometer (mu m). Further subgrouping was based on measurement area: axial, occlusal, and marginal. When we analyzed marginal fit, there were no statistically significant differences between the two techniques in any of the subgroups. The measurement of internal fit metal and ceramic restorations provided no significant differences. However, milled acrylic resin restorations showed a significantly higher occlusal gap compared to 3D printed prostheses with 39.12 mu m (95 % CI: 12.44; 65.79). In the case of trueness, a statistically significant difference was observed between ceramic AM and SM restorations with -47.76 mu m (95 % CI: -95.51; -0.00). QUIN and GRADE Pro tools were used to evaluate the risk of bias and certainty of evidence. Conclusion: Fixed restorations manufactured with additive manufacturing are valid alternatives to subtractive manufacturing in the digital workflow. Clinical significance: Additive manufacturing is an accurate and cost-effective manufacturing method of digital workflow, especially for metal and resin fixed restorations. Once the challenges in ceramics manufacturing are addressed, AM will show more significant promise in the field.
引用
收藏
页数:21
相关论文
共 141 条
  • [61] Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique
    Kang, Seen-Young
    Park, Jung-Hyun
    Kim, Ji-Hwan
    Kim, Woong-Chul
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (05) : 354 - 360
  • [62] Accuracy of Additively Manufactured and Milled Interim 3-Unit Fixed Dental Prostheses
    Karasan, Duygu
    Legaz, Juan
    Boitelle, Philippe
    Mojon, Philippe
    Fehmer, Vincent
    Sailer, Irena
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 : 58 - 69
  • [63] Marginal and internal discrepancies associated with carbon digital light synthesis additively manufactured interim crowns
    Khanlar, Leila Nasiry
    Barmak, Abdul Basir
    Oh, Youngju
    Mendha, Umar
    Yared, Sami
    Zandinejad, Amirali
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (01) : 108.e1 - 108.e6
  • [64] Trueness of milled prostheses according to number of ball-end mill burs
    Kim, Chong-Myeong
    Kim, So-Ri
    Kim, Ji-Hwan
    Kim, Hae-Young
    Kim, Woong-Chul
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) : 624 - 629
  • [65] Comparison and evaluation of marginal and internal gaps in cobalt-chromium alloy copings fabricated using subtractive and additive manufacturing
    Kim, Dong-Yeon
    Kim, Ji-Hwan
    Kim, Hae-Young
    Kim, Woong-Chul
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (01) : 56 - 64
  • [66] A microcomputed tomography evaluation of the marginal fit of cobalt-chromium alloy copings fabricated by new manufacturing techniques and alloy systems
    Kim, Eun-Ha
    Lee, Du-Hyeong
    Kwon, Sung-Min
    Kwon, Tae-Yub
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (03) : 393 - 399
  • [67] Fit of lithium disilicate crowns fabricated from conventional and digital impressions assessed with micro-CT
    Kim, Jae-Hyun
    Jeong, Ji-Hye
    Lee, Jin-Han
    Cho, Hye-Won
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (04) : 551 - 557
  • [68] THREE-DIMENSIONAL EVALUATION OF GAPS ASSOCIATED WITH FIXED DENTAL PROSTHESES FABRICATED WITH NEW TECHNOLOGIES
    Kim, Ki-Baek
    Kim, Jae-Hong
    Kim, Woong-Chul
    Kim, Ji-Hwan
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (06) : 1432 - 1436
  • [69] Evaluation of intaglio surface trueness, wear, and fracture resistance of zirconia crown under simulated mastication: a comparative analysis between subtractive and additive manufacturing
    Kim, Yong-Kyu
    Han, Jung-Suk
    Yoon, Hyung-In
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (02) : 122 - 132
  • [70] Lebon N, 2016, INT J COMPUT DENT, V19, P45