Frequency analysis of flow and heat transfer near reattachment point behind a backward-facing step

被引:0
|
作者
Yamada, Shunsuke [1 ]
Funami, Yuki [1 ]
Nakamura, Hajime [1 ]
机构
[1] Natl Def Acad, Dept Mech Engn, 1-10-20 Hashirimizu, Yokosuka, Kanagawa 2398686, Japan
关键词
Backward-facing step; Reattachment flow; Convective heat transfer; Particle image velocimetry; High-speed infrared thermography; LARGE-EDDY SIMULATION; TURBULENT-FLOW; FLUCTUATIONS; SURFACE; BEHAVIOR;
D O I
10.1016/j.ijheatfluidflow.2025.109771
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the nature of the flow and heat transfer near the flow reattachment point behind a backward-facing step was experimentally investigated at a Reynolds number of 5400. The unsteady fluctuations of the velocity and temperature were simultaneously measured by particle image velocimetry in a two-dimensional plane that contained three components (2D-3C PIV) and by high-speed infrared thermography. To evaluate the mechanism of the flow and heat transfer, the vorticity and heat transfer coefficients were calculated from the time history data for each velocity and temperature. Also, the spatial flow structure and the characteristic frequency of the flow and heat transfer fluctuations were investigated by using two-point correlation, a fast Fourier transform, and a continuous wavelet transform. These results showed that the characteristic frequencies for each velocity and heat transfer coefficient appeared near the wall. It was revealed that the temporal and spatial fluctuations of the heat transfer coefficient corresponded to that of the streamwise flow. From the time-moving averaging streamwise velocity and heat transfer with the conditional sampling, the zero-velocity line at the low nondimensional frequency of 0.06 fluctuated near the wall as time advance, and the high heat transfer appeared near the instantaneous reattachment point.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Experimental study of the separated flow structure behind a backward-facing step and a passive disturbance
    V. I. Terekhov
    Ya. I. Smul’skii
    K. A. Sharov
    Journal of Applied Mechanics and Technical Physics, 2016, 57 : 180 - 187
  • [32] Experimental study of nanofluids flow and heat transfer over a backward-facing step channel
    Hilo, Ali Kareem
    Abu Talib, Abd Rahim
    Acosta Iborra, Antonio
    Sultan, Mohammed Thariq Hameed
    Hamid, Mohd Faisal Abdul
    POWDER TECHNOLOGY, 2020, 372 : 497 - 505
  • [33] Experimental study of the separated flow structure behind a backward-facing step and a passive disturbance
    Terekhov, V. I.
    Smul'skii, Ya. I.
    Sharov, K. A.
    JOURNAL OF APPLIED MECHANICS AND TECHNICAL PHYSICS, 2016, 57 (01) : 180 - 187
  • [34] CONVECTIVE HEAT-TRANSFER COEFFICIENT IDENTIFICATION BEHIND A BACKWARD-FACING STEP BY ACTIVE INFRARED THERMOGRAPHY
    DUMOULIN, J
    REULET, P
    PLAZANET, M
    MILLAN, P
    REVUE GENERALE DE THERMIQUE, 1995, 34 (403-04): : 478 - 492
  • [35] Unsteady Behavior of a Backward-facing Step in Forced Flow
    Chovet, Camila
    Lippert, Marc
    Keirsbulck, Laurent
    Foucaut, Jean-Marc
    FLOW TURBULENCE AND COMBUSTION, 2019, 102 (01) : 145 - 165
  • [36] Control of a channel-flow behind a backward-facing step by suction/blowing
    Uruba, Vaclav
    Jonas, Pavel
    Mazur, Oton
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2007, 28 (04) : 665 - 672
  • [38] The effect of inlet pulsations on the backward-facing step flow
    Tihon, J.
    Penkavova, V.
    Pantzali, M.
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2010, 29 (03) : 224 - 235
  • [39] Analysis of characteristic wake flow modes on a generic transonic backward-facing step configuration
    Statnikov, V.
    Bolgar, I.
    Scharnowski, S.
    Meinke, M.
    Kaehler, C. J.
    Schroeder, W.
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2016, 59 : 124 - 134
  • [40] Heat transfer control of a backward-facing step flow in a duct by means of miniature electromagnetic actuators
    Inaoka, K
    Nakamura, K
    Senda, M
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2004, 25 (05) : 711 - 720