Quantitative analysis of the effect of clothing on the oscillometric waveform envelope and oscillometric blood pressure measurements

被引:0
作者
Kim, Jeonghoon [1 ]
Lee, Jongshill [2 ]
Lee, Jeyeon [2 ]
Park, Hoon-Ki [3 ]
Kim, In Young [2 ]
机构
[1] Hanyang Univ, Dept Elect Engn, Seoul 04763, South Korea
[2] Hanyang Univ, Dept Biomed Engn, Seoul 04763, South Korea
[3] Hanyang Univ, Coll Med, Dept Family Med, Seoul 04763, South Korea
关键词
Blood pressure; Blood pressure determination; Oscillometric waveform envelope; Oscillogram; ROLLED-UP SLEEVE; BARE ARM; CUFF; RATIOS;
D O I
10.1007/s13534-025-00467-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose To ensure accurate blood pressure (BP) measurement, it is important to follow guidelines, such as wearing the cuff on the bare arm. However, this recommendation is often challenging due to patients being dressed. This study quantitatively evaluates how wearing a cuff over clothing impacts BP accuracy using oscillometric waveform analysis. Methods BP was measured under three conditions: thick sleeve (3.5 mm), thin sleeve (1.5 mm), and bare arm. Oscillometric waveform envelopes (OMWE) were analyzed to extract features like maximum amplitude, width, and slope for each condition. BP measurements and extracted features from the bare arm condition were compared with those from each sleeve condition. Results The mean systolic blood pressure (SBP) and pulse pressure (PP) increased by 11.73 and 10.04 mmHg under thick sleeve conditions. These also increased by 4.308 and 4.731 mmHg under thin sleeve conditions (Thick: p < 0.001, Thin: p < 0.05). The mean of mean arterial pressure (MAP) and OMWE width increased by 5.039 and 5.059 mmHg under thick sleeve conditions (Thick: p < 0.025). The mean of maximum amplitude of OMWE under thick and thin sleeves decreased by 0.9428 and 0.4017 mmHg (Thick, Thin: p < 0.001). Diastolic blood pressure (DBP) increased under thick sleeve conditions; however, this was not statistically significant. Conclusion Wearing the cuff over clothing altered OMWE morphology, resulting in a lower, flatter shape similar to that seen in hypertensives. This significantly affected BP readings, particularly SBP. Therefore, following guidelines for cuff placement on bare arms is crucial for accurate BP measurement.
引用
收藏
页码:525 / 536
页数:12
相关论文
共 50 条
[31]   Inaccuracy in Determining Mean Arterial Pressure With Oscillometric Blood Pressure Techniques [J].
Vos, Jorn ;
Vincent, Hieronymus H. ;
Verhaar, Marianne C. ;
Bos, Willem J. W. .
AMERICAN JOURNAL OF HYPERTENSION, 2013, 26 (05) :624-629
[32]   EVALUATION OF AGREEMENT BETWEEN OSCILLOMETRIC AND DIRECT BLOOD PRESSURE MEASUREMENTS IN ANESTHETIZED TIGERS (PANTHERA TIGRIS) [J].
Smith, Christopher K. ;
Chow, Natalie ;
Zhu, Xiaojuan ;
Cushing, Andrew C. .
JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2022, 53 (04) :777-784
[33]   CHANGES IN OSCILLOMETRIC PULSE AMPLITUDE ENVELOPE WITH CUFF SIZE - IMPLICATIONS FOR BLOOD-PRESSURE MEASUREMENT CRITERIA AND CUFF SIZE SELECTION [J].
NG, KG ;
SMALL, CF .
JOURNAL OF BIOMEDICAL ENGINEERING, 1993, 15 (04) :279-282
[34]   Intraoperative Blood Pressure Misclassification Due to Inaccuracy of Noninvasive Oscillometric Cuff-Measured Blood Pressure [J].
Kim, Danny Sungsoo ;
Kwon, Sohee ;
Bovik, Alan C. ;
Markey, Mia K. ;
Giovannucci, Edward L. ;
Cannesson, Maxime .
HYPERTENSION, 2025, 82 (02) :e1-e3
[35]   OPTIMAL SITES FOR FOREHEAD OSCILLOMETRIC BLOOD-PRESSURE MONITORING [J].
LEE, TK ;
SILVA, FH ;
EGBERT, TP ;
WESTENSKOW, DR .
JOURNAL OF CLINICAL MONITORING, 1995, 11 (05) :298-304
[36]   Clinical evaluation of an automated oscillometric blood pressure wrist device [J].
Cuckson, AC ;
Moran, P ;
Seed, P ;
Reinders, A ;
Shennan, AH .
BLOOD PRESSURE MONITORING, 2004, 9 (01) :31-37
[37]   Supraorbital artery as an alternative site for oscillometric blood pressure measurement [J].
Lee, TK ;
Egbert, TP ;
Westenskow, DR .
JOURNAL OF CLINICAL MONITORING, 1996, 12 (04) :293-297
[38]   Validation of Oscillometric Pulse Wave Analysis Measurements in Children [J].
Stoner, Lee ;
Lambrick, Danielle M. ;
Westrupp, Nicole ;
Young, Joanna ;
Faulkner, James .
AMERICAN JOURNAL OF HYPERTENSION, 2014, 27 (06) :865-872
[39]   Blood Pressure Estimation Using Maximum Slope of Oscillometric Pulses [J].
Mafi, Majid ;
Rajan, Sreeraman ;
Bolic, Miodrag ;
Groza, Voicu Z. ;
Dajani, Hilmi R. .
2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, :3239-3242
[40]   Performance of Different Oscillometric Blood Pressure Algorithms in Patients with Chronic Kidney Disease [J].
Ringrose, Jennifer S. ;
Smith, Kevan ;
Jalali, Afrooz ;
Khinda, Harsimran ;
Wirzba, Isaac ;
Eche-Ameh, Hannah ;
Bello, Aminu K. ;
Braam, Branko ;
Padwal, Raj .
HYPERTENSION, 2018, 72