Quantitative analysis of the effect of clothing on the oscillometric waveform envelope and oscillometric blood pressure measurements

被引:0
作者
Kim, Jeonghoon [1 ]
Lee, Jongshill [2 ]
Lee, Jeyeon [2 ]
Park, Hoon-Ki [3 ]
Kim, In Young [2 ]
机构
[1] Hanyang Univ, Dept Elect Engn, Seoul 04763, South Korea
[2] Hanyang Univ, Dept Biomed Engn, Seoul 04763, South Korea
[3] Hanyang Univ, Coll Med, Dept Family Med, Seoul 04763, South Korea
关键词
Blood pressure; Blood pressure determination; Oscillometric waveform envelope; Oscillogram; ROLLED-UP SLEEVE; BARE ARM; CUFF; RATIOS;
D O I
10.1007/s13534-025-00467-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose To ensure accurate blood pressure (BP) measurement, it is important to follow guidelines, such as wearing the cuff on the bare arm. However, this recommendation is often challenging due to patients being dressed. This study quantitatively evaluates how wearing a cuff over clothing impacts BP accuracy using oscillometric waveform analysis. Methods BP was measured under three conditions: thick sleeve (3.5 mm), thin sleeve (1.5 mm), and bare arm. Oscillometric waveform envelopes (OMWE) were analyzed to extract features like maximum amplitude, width, and slope for each condition. BP measurements and extracted features from the bare arm condition were compared with those from each sleeve condition. Results The mean systolic blood pressure (SBP) and pulse pressure (PP) increased by 11.73 and 10.04 mmHg under thick sleeve conditions. These also increased by 4.308 and 4.731 mmHg under thin sleeve conditions (Thick: p < 0.001, Thin: p < 0.05). The mean of mean arterial pressure (MAP) and OMWE width increased by 5.039 and 5.059 mmHg under thick sleeve conditions (Thick: p < 0.025). The mean of maximum amplitude of OMWE under thick and thin sleeves decreased by 0.9428 and 0.4017 mmHg (Thick, Thin: p < 0.001). Diastolic blood pressure (DBP) increased under thick sleeve conditions; however, this was not statistically significant. Conclusion Wearing the cuff over clothing altered OMWE morphology, resulting in a lower, flatter shape similar to that seen in hypertensives. This significantly affected BP readings, particularly SBP. Therefore, following guidelines for cuff placement on bare arms is crucial for accurate BP measurement.
引用
收藏
页码:525 / 536
页数:12
相关论文
共 50 条
  • [21] Determination of Blood Pressure and Hemodynamics from Oscillometric Waveforms
    Jilek, J.
    Stork, M.
    NEW ASPECTS OF SYSTEMS, PTS I AND II, 2008, : 109 - +
  • [22] Model-Based Oscillometric Blood Pressure Estimation
    Forouzanfar, Mohamad
    Dajani, Hilmi R.
    Groza, Voicu Z.
    Bolic, Miodrag
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 443 - 448
  • [23] Accuracy of oscillometric blood pressure measurement in atrial fibrillation
    Feenstra, Rudolf K.
    Allaart, Cor P.
    Berkelmans, Gijs F. N.
    Westerhof, Berend E.
    Smulders, Yvo M.
    BLOOD PRESSURE MONITORING, 2018, 23 (02) : 59 - 63
  • [24] Comparison between oscillometric and invasive blood pressure measurements in critically ill premature infants
    Takci, Sahin
    Yigit, Sule
    Korkmaz, Ayse
    Yurdakok, Murat
    ACTA PAEDIATRICA, 2012, 101 (02) : 132 - 135
  • [25] Blood Pressure Estimation using Oscillometric Pulse Morphology
    Mafi, Majid
    Rajan, Sreeraman
    Bolic, Miodrag
    Groza, Voicu Z.
    Dajani, Hilmi R.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2492 - 2496
  • [26] Auscultatory versus oscillometric measurement of blood pressure in octogenarians
    Rosholm, Jens-Ulrik
    Arnspang, Sidsel
    Matzen, Lars
    Jacobsen, Ib A.
    BLOOD PRESSURE, 2012, 21 (05) : 269 - 272
  • [27] Accuracy of an oscillometric blood pressure monitor in anesthetized pigs
    Reed, Rachel
    Barletta, Michele
    Grimes, Janet
    Mumaw, Jennifer
    Park, Hea Jin
    Giguere, Steeve
    Azain, Michael
    Fang, Xi
    Quandt, Jane
    LABORATORY ANIMALS, 2018, 52 (05) : 490 - 496
  • [28] Comparison of Invasive and Oscillometric Blood Pressure Measurement in Obese and Nonobese Children
    Fundora, Michael P.
    Beshish, Asaad G.
    Rao, Nikita
    Berry, Christopher M.
    Figueroa, Janet
    McCracken, Courtney
    Maher, Kevin O.
    AMERICAN JOURNAL OF HYPERTENSION, 2021, 34 (06) : 619 - 625
  • [29] Evaluation of oscillometric blood pressure measurement devices available for online sale
    Vigato, Estefanie Siqueira
    de Souza, Mariana Castro
    Dordetto, Priscila Rangel
    Tatagiba Lamas, Jose Luiz
    REVISTA BRASILEIRA DE ENFERMAGEM, 2022, 75 (04)
  • [30] Oscillometric Blood Pressure Estimation Using Principal Component Analysis and Neural Networks
    Forouzanfar, Mohamad
    Dajani, Hilmi R.
    Groza, Voicu Z.
    Bolic, Miodrag
    Rajan, Sreeraman
    IEEE TIC-STH 09: 2009 IEEE TORONTO INTERNATIONAL CONFERENCE: SCIENCE AND TECHNOLOGY FOR HUMANITY, 2009, : 981 - 986