Reinforced lengthening Achilles tendon Z-plasty - ex vivo assessment of biomechanical augmentation with surgical-fiberlock technology

被引:0
作者
Dreher, Thomas [1 ,2 ]
Moehl, Andrea [3 ]
Bachmann, Elias [3 ]
Nieuwland, Arend [1 ,2 ]
Snedeker, Jess G. [3 ,4 ,5 ]
机构
[1] Univ Zurich, Balgrist Univ Hosp Zurich, Dept Pediat Orthoped, Zurich, Switzerland
[2] Univ Childrens Hosp Zurich, Dept Pediat Orthoped & Traumatol, Zurich, Switzerland
[3] ZuriMED Technol AG, Zurich, Switzerland
[4] Univ Zurich, Balgrist Univ Hosp, Dept Orthoped, Zurich, Switzerland
[5] Swiss Fed Inst Technol, Inst Biomech, Zurich, Switzerland
关键词
ROTATOR CUFF; REPAIR; RUPTURE; RECONSTRUCTION; IMMOBILIZATION; RECESSION; STIFFNESS; CHILDREN; SURGERY; TEARS;
D O I
10.1007/s00264-025-06481-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Tendon lengthening is a common lower limb surgical procedure in paediatric orthopaedics and deformity correction. Healing of a lengthened tendon is typically supported by casting and unloading of the operated limb. Although tendon rupture or overcorrection may adversely affect surgical outcomes, few studies have examined surgical means of improving post-operative stability of the tendon. We aim to evaluate a novel method for augmenting Z-Plasty tendon lengthening as a first step to clinical translation. Methods In this experimental ex vivo study, we employed a bovine flexor tendon model (n = 18) to examine a novel mechanical augmentation method after tendon lengthening by Z-plasty. Conventional surgical suturing of the imposed Z-plasty (n = 6) and an experimental group (n = 6), in which additional augmentation was performed by interlocking fibres of a biomaterial scaffold to the underlying tendon using a novel micro-needling technique, were compared to native tendons (n = 6). Results The needle interlocked scaffold successfully augmented the suture repair, showing more than doubled ultimate failure force compared to controls (482 +/- 107 N vs. 206 +/- 37 N, p < 0.01), and more than 1.5-fold repair stiffness (41 +/- 7 N/mm vs. 26 +/- 9 N/mm, p < 0.01). Conclusion We conclude that the use of an interpenetrating biomaterial scaffold represents a promising new approach for improving biomechanical tendon properties, which may have an implication on the stability of tendon suture, lengthening and tendon transfer procedures as well as on post-operative management and earlier mobilization.
引用
收藏
页码:1055 / 1063
页数:9
相关论文
共 48 条
  • [1] Abdelsattar M, 2018, J SPORT SCI MED, V17, P223
  • [2] Overlapping repair and epitenon healing are more stable biomechanically than side to side repair and endotenon healing in achilles tendon lengthening with Z plasty
    Akbulut, Deniz
    Alpay, Yakup
    Kirat, Akay
    Albayrak, Kutalmis
    Asansu, Mustafa Akif
    Akpinar, Evren
    [J]. FOOT AND ANKLE SURGERY, 2022, 28 (08) : 1372 - 1376
  • [3] Reconstruction of massive rotator cuff lesions with a synthetic interposition graft: a prospective study of 41 patients
    Audenaert, E
    Van Nuffel, J
    Schepens, A
    Verhelst, M
    Verdonk, R
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (04) : 360 - 364
  • [4] TRICEPS SURAE SYNDROME IN CEREBRAL PALSY - AN OPERATION TO AID IN ITS RELIEF
    BAKER, LD
    [J]. AMA ARCHIVES OF SURGERY, 1954, 68 (02): : 216 - 221
  • [5] A biomechanical study of Achilles tendon repair augmentation using GraftJacket matrix
    Barber, F. Alan
    McGarry, John E.
    Herbert, Morley A.
    Anderson, Robert Bentley
    [J]. FOOT & ANKLE INTERNATIONAL, 2008, 29 (03) : 329 - 333
  • [6] Nonoperative Dynamic Treatment of Acute Achilles Tendon Rupture: The Influence of Early Weight-Bearing on Clinical Outcome A Blinded, Randomized Controlled Trial
    Barfod, Kristoffer Weisskirchner
    Bencke, Jesper
    Lauridsen, Hanne Bloch
    Ban, Ilija
    Ebskov, Lars
    Troelsen, Anders
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (18) : 1497 - 1503
  • [7] Baumann J.U., 1989, Operative Orthopadie und Traumatologie, V1, P254, DOI [10.1007/BF02514828, DOI 10.1007/BF02514828]
  • [8] Collagen Ribbon Augmentation of Achilles Tendon Tears: A Biomechanical Evaluation
    Berlet, Gregory C.
    Hyer, Christopher F.
    Lee, Thomas H.
    Blum, Barbara E.
    [J]. JOURNAL OF FOOT & ANKLE SURGERY, 2014, 53 (03) : 298 - 302
  • [9] Static and Dynamic Gait Parameters Before and After Multilevel Soft Tissue Surgery in Ambulating Children With Cerebral Palsy
    Bernthal, Nicholas M.
    Gamradt, Seth C.
    Kay, Robert M.
    Wren, Tishya A. L.
    Cuomo, Anna V.
    Reid, Jeremy
    Bales, Joshua
    Otsuka, Norman Y.
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2010, 30 (02) : 174 - 179
  • [10] Mechanical properties of animal ligaments: a review and comparative study for the identification of the most suitable human ligament surrogates
    Burgio, V.
    Casari, S.
    Milizia, M.
    Sanna, F.
    Spezia, G.
    Civera, M.
    Reinoso, M. Rodriguez
    Bertuglia, A.
    Surace, C.
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2023, 22 (05) : 1645 - 1683