摘要
Background: Implantable cardioverter-defibrillator (ICD) is indicated for primary prevention in patients with left ventricular ejection fraction (LVEF) <= 35% and New York Heart Association class II or III heart failure despite 3 months of optimal medical therapy. However, studies that support this recommendation are over 20 years old, and they may not reflect modern heart failure patients' characteristics. Objectives: Retrospectively evaluate patients who received an ICD for primary prevention. Methods: All-cause and sudden death rates were compared in patients who received ICD between January 1, 2015 and March 1, 2020 and those who did not accept ICD. Variables were analyzed at a 95% confidence interval, and p < 0.05 was considered as significant. Results: When comparing mortality rates between patients with and without ICD, 67 of 228 patients (29.4%) in the ICD group and 39 of 150 patients (26%) in the control group died from all causes (p = 0.473). Age, LVEF, BNP value, and hospitalization were found to be independent predictors of all-cause mortality. Patients with BNP above 508.5, LVEF below 24.5%, and age over 68.5 years had a 25-fold increased all-cause mortality. Coronary artery disease was not found to be an independent risk factor. Survival in the control group was statistically significantly better in the first months. Although there was no statistical difference in the long term, survival was numerically better in the ICD arm. This could be attributed to the fact that ICD implantations were performed on patients with worse clinical conditions. The higher survival rate observed in patients with ICD may be due to the fact that they came in for device control and remained in follow-up. Conclusions:With advances in the treatment of heart failure, ICD implantation should be performed in selected patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Syncope in Primary Prevention Implantable Cardioverter Defibrillator Patients
    Goldenberg, Gustavo
    Bental, Tamir
    Kadmon, Udi
    Zabarsky, Ronit
    Kusnick, Jairo
    Barsheshet, Mon
    Golovchiner, Gregory
    Strasberg, Boris
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2016, 18 (06): : 318 - 321
  • [42] Incidence of Appropriate Cardioverter-Defibrillator Shocks and Mortality in Patients With Heart Failure Treated With Combined Cardiac Resynchronization Plus Implantable Cardioverter-Defibrillator Therapy Versus Implantable Cardioverter-Defibrillator Therapy
    Desai, Harit
    Aronow, Wilbert S.
    Ahn, Chul
    Tsai, Fausan S.
    Lai, Hoang M.
    Gandhi, Kaushang
    Amin, Harshad
    Frishman, William H.
    Kalapatapu, Kumar
    Cohen, Martin
    Sorbera, Carmine
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY AND THERAPEUTICS, 2010, 15 (01) : 37 - 40
  • [43] Implantable cardioverter-defibrillator shock prevention does not reduce mortality: A systemic review
    Ha, Andrew H.
    Ham, Inje
    Nair, Girish M.
    Connolly, Stuart J.
    Dorian, Paul
    Morillo, Carlos A.
    Healey, Jeff S.
    HEART RHYTHM, 2012, 9 (12) : 2068 - 2074
  • [44] Implantable cardioverter-defibrillator therapy in clinical practice
    Cesario, DA
    Dec, GW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (08) : 1507 - 1517
  • [45] THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - CLINICAL-RESULTS
    PALATIANOS, GM
    THURER, RJ
    COOPER, DK
    GEORGAKAKIS, GE
    TUCKER, RL
    FERNANDEZ, P
    INTERIAN, A
    MYERBURG, RJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02): : 297 - 301
  • [46] CLINICAL-PERFORMANCE OF THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    MIROWSKI, M
    REID, PR
    MOWER, MM
    WATKINS, L
    PLATIA, EV
    GRIFFITH, LSC
    GUARNIERI, T
    THOMAS, A
    JUANTEGUY, JM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (06): : 1345 - 1350
  • [47] Clinical Outcomes and Characteristics With Dofetilide in Atrial Fibrillation Patients Considered for Implantable Cardioverter-Defibrillator
    Koene, Ryan J.
    Menon, Vivek
    Cantillon, Daniel J.
    Dresing, Thomas J.
    Martin, David O.
    Kanj, Mohamed
    Saliba, Walid I.
    Tarakji, Khaldoun G.
    Baranowski, Bryan
    Hussein, Ayman A.
    Tchou, Patrick J.
    Bhargava, Mandeep
    Callahan, Thomas D.
    Rickard, John W.
    Niebauer, Mark J.
    Chung, Mina K.
    Varma, Niraj
    Wilkoff, Bruce L.
    Lindsay, Bruce D.
    Wazni, Oussama M.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2020, 13 (07): : 676 - 684
  • [48] Clinical follow-up of patients with implantable cardioverter-defibrillator
    da Fonseca, Silvia Martelo Souza
    Belo, Luiz Gustavo
    Carvalho, Hecio
    Araujo, Nilson
    Munhoz, Claudio
    Siqueira, Leonardo
    Maciel, Washington
    Andrea, Eduardo
    Atie, Jacob
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2007, 88 (01) : 8 - 16
  • [50] CLINICAL-EXPERIENCE WITH THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    MIROWSKI, M
    REID, PR
    MOWER, MM
    WATKINS, L
    PLATIA, EV
    GRIFFITH, LSC
    JUANTEGUY, JM
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1984, 427 (JUN) : 297 - 306