摘要
Detecting kidney function biomarkers is critical for the early diagnosis of kidney diseases and monitoring treatment efficacy. In this work, a portable, 3D-printed colorimetric sensor platform was developed to detect key kidney biomarkers: uric acid, creatinine, and albumin. The platform features a 3D-printed enclosure with integrated diffused LED lighting to ensure a controlled environment for image acquisition. A disposable 3D-printed flow cell holds samples, ensuring precision and minimizing contamination. The sensor relies on colorimetric analysis, where a reagent reacts with blood serum to produce a color shift proportional to the biomarker concentration. Using a smartphone, the color change is captured, and RGB values are normalized to calculate concentrations based on the Beer-Lambert Law. The system adapts to variations in smartphones, reagent brands, and lighting conditions through an adaptive calibration algorithm, ensuring flexibility and accuracy. The sensor demonstrated good linear detection ranges for uric acid (1-30 mg/dL), creatinine (0.1-20 mg/dL), and albumin (0.1-8 g/dL), with detection limits of 1.15 mg/dL, 0.15 mg/dL, and 0.11 g/dL, respectively. These results correlated well with commercial biochemistry analyzers. Additionally, an Android application was developed to handle image processing and database management, providing a user-friendly interface for real-time blood analysis. This portable, cost-effective platform shows significant potential for point-of-care diagnostics and remote health monitoring.
引用
收藏
页数:17
相关论文
共 24 条
[1]  
Amin NU., 2014, J Cardiovasc Dis, V2, P1
[2]   Portable Electrochemiluminescence Platform With Laser-Induced Graphene-Based U-Shaped Bipolar Electrode for Selective Sensing of Various Analytes [J].
Bhaiyya, Manish ;
Pattnaik, Prasant Kumar ;
Goel, Sanket .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2021, 68 (05) :2447-2454
[3]   Prevalence and socio-economic aspects of chronic kidney disease [J].
Bommer, J .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2002, 17 :8-12
[4]  
Chen H, 2022, Zhonghua Yu Fang Yi Xue Za Zhi, V56, P1112, DOI 10.3760/cma.j.cn112150-20211203-01118
[5]   A rapid, simple measurement of human albumin in whole blood using a fluorescence immunoassay (I) [J].
Choi, S ;
Choi, EY ;
Kim, DJ ;
Kim, JH ;
Kim, TS ;
Oh, SW .
CLINICA CHIMICA ACTA, 2004, 339 (1-2) :147-156
[6]   Point-of-care blood tests using a smartphone-based colorimetric analyzer for health check-up [J].
Chunta, Suticha ;
Jarujamrus, Purim ;
Prakobkij, Akarapong ;
Khongwichit, Soemwit ;
Ditcharoen, Nadh ;
Pencharee, Somkid ;
Amatatongchai, Maliwan .
MICROCHIMICA ACTA, 2024, 191 (07)
[7]   Progress of the Electrochemiluminescence Biosensing Strategy for Clinical Diagnosis with Luminol as the Sensing Probe [J].
Fang, Chen ;
Li, Huiling ;
Yan, Jilin ;
Guo, Heming ;
Tu Yifeng .
CHEMELECTROCHEM, 2017, 4 (07) :1587-1593
[8]   Blood Cholesterol Monitoring With Smartphone as Miniaturized Electrochemical Analyzer for Cardiovascular Disease Prevention [J].
Fu, Yusheng ;
Guo, Jinhong .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2018, 12 (04) :784-790
[9]  
Kapoor S., 2013, Int. J. Sci. Res, V2, P2319
[10]  
Niculescu MS, 2020, REV ROUM SCI TECH-EL, V65, P271