A personal glucose meter (PGM) is a medical device that measures blood glucose levels and can be found worldwide. Owing to their sensitivity, simplicity, portability, and low cost, PGMs stand as one of the most frequently utilized analytical methods. This work reviews the different applied methodologies for detecting analytes other than glucose employing a PGM and how it can be incorporated for point-of-care diagnosis needs. To visualize the variants, first, a classification is made according to the biorecognition elements used (aptamers, antibodies, etc.), and where the determination of different analytes is done through the glucose signal using different glucose-generating enzymes such as invertase or glucosidase. Transduction can also be based on the use of nanocarriers that generally encapsulate glucose, although it is also possible to find a combination of the two aforementioned strategies. The PGM can also be used for the direct detection of interfering substances of the biosensor, such as NADH or paracetamol. Lastly, we discuss how a PGM might have been implemented to detect COVID-19 and how it could be used on a massive scale for the point-of-care diagnosis of a pandemic.
引用
收藏
页数:20
相关论文
共 68 条
  • [1] Leal Filho W., Marisa Azul A., Brandli L., Lange Salvia A., Wall T., Sustainable Development Goals (SDGs), Gender Equality. Encyclopedia of the UN Sustainable Development Goals, (2021)
  • [2] (2022)
  • [3] (2015)
  • [4] Bueno de Mesquita J., Thomas R., Gauter C., Havkwist A., Hoddy R., Larasati A., Gjerdset I.L., Perrone G., Sadiq T., Smith R.A., Monitoring the sustainable development goals through human rights accountability reviews, Bull. World Health Organ, 96, pp. 627-633, (2018)
  • [5] Kozel T.R., Burnham-Marusich A.R., Point-of-Care Testing for Infectious Diseases: Past, Present, and Future, J. Clin. Microbiol, 55, pp. 2313-2320, (2017)
  • [6] Harichund C., Moshabela M., Acceptability of HIV Self-Testing in Sub-Saharan Africa: Scoping Study, AIDS Behav, 22, pp. 560-568, (2018)
  • [7] Kost G.J., Tran N.K., Louie R.F., Point-of-Care Testing: Principles, Practice, and Critical-Emergency-Disaster Medicine, Encyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation, (2008)
  • [8] Rasmi Y., Li X., Khan J., Ozer T., Choi J.R., Emerging Point-of-care biosensors for rapid diagnosis of COVID-19: Current progress, challenges, and future prospects, Anal. Bioanal. Chem, 413, pp. 4137-4159, (2021)
  • [9] Teymourian H., Barfidokht A., Wang J., Electrochemical glucose sensors in diabetes management: An updated review (2010–2020), Chem. Soc. Rev, 49, pp. 7671-7709, (2020)
  • [10] Lisi F., Peterson J.R., Gooding J.J., The application of personal glucose meters as universal point-of-care diagnostic tools, Biosens. Bioelectron, 148, (2020)