Capacitively Coupled Electrical Impedance Tomography in Lung Imaging

被引:1
|
作者
Guo, Yuxi [1 ]
Zhu, Liying [2 ]
Wang, Minmin [3 ]
Jiang, Yandan [4 ]
Soleimani, Manuchehr [5 ]
Zhang, Maomao [1 ]
机构
[1] Univ Elect Sci & Technol China, Shenzhen Inst Adv Study, Shenzhen 518071, Peoples R China
[2] City Univ Hong Kong, Dept Biomed Engn, Hong Kong, Peoples R China
[3] Westlake Univ, Westlake Inst Optoelect, Hangzhou 310024, Peoples R China
[4] Zhejiang Univ, Coll Control Sci & Engn, State Key Lab Ind Control Technol, Hangzhou 310027, Peoples R China
[5] Univ Bath, Dept Elect & Elect Engn, Bath BA2 7AY, England
关键词
Impedance; Impedance measurement; Electrodes; Electrical impedance tomography; Monitoring; Lung; Imaging; Capacitively coupled electrical impedance tomography (CCEIT); electrical impedance tomography (EIT); lung imaging;
D O I
10.1109/JSEN.2024.3432991
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical impedance tomography (EIT) has been applied in bedside respiratory monitoring since it is a nonradioactive and noninvasive method. However, adverse effects of direct skin contact limit its usage. This article proposes the application of capacitively coupled EIT (CCEIT) for lung monitoring which avoids the limitation of galvanic contact measurement by using contactless measurements suitable for wearable devices, and it could provide a comfortable and hygienic user experience. This study primarily confirms the feasibility of CCEIT in monitoring respiration through a human body experiment, showing that both magnitude and phase angle of respiratory impedance effectively reflect breathing status. Numerical simulation is conducted to further explore the effects of frequency and insulation layer on CCEIT's impedance measurements and image reconstruction through constructing a digital twin lung model coupling biomechanical and electrical fields as a novel imaging modality. The time-difference imaging based on variations in magnitude and phase angle of impedance is proposed for imaging the respiratory phases of the lungs. CCEIT shows excellent performance in lung monitoring, particularly when operating at high frequencies and with small insulating layer thickness. Utilizing phase angle of impedance yields better imaging outcomes than magnitude, and at a high frequency of 20 MHz, even a 9 mm air gap can still provide satisfactory imaging results. CCEIT has broader applications than EIT, operating over a wide frequency range and utilizing both magnitude and phase angle information of impedance. This makes it promising for more accurate lung image reconstruction and impedance measurements in lung monitoring.
引用
收藏
页码:33072 / 33082
页数:11
相关论文
共 50 条
  • [21] Assessment of Changes in Distribution of Lung Perfusion by Electrical Impedance Tomography
    Frerichs, Inez
    Pulletz, Sven
    Elke, Gunnar
    Reifferscheid, Florian
    Schaedler, Dirk
    Scholz, Jens
    Weiler, Norbert
    RESPIRATION, 2009, 77 (03) : 282 - 291
  • [22] Assessment of lung collapse with electrical impedance tomography: a simulation study
    Denai, M. A.
    Mahfouf, M.
    Meekings, T.
    Mills, G. H.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (04) : 580 - 580
  • [23] Sensitivity study of an ultrasound coupled transrectal electrical impedance tomography system for prostate imaging
    Wan, Y.
    Halter, R.
    Borsic, A.
    Manwaring, P.
    Hartov, A.
    Paulsen, K.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (08) : S17 - S29
  • [24] Magnetic Resonance Electrical Impedance Tomography For Anisotropic Conductivity Imaging
    Degirmenci, E.
    Eyuboglu, B. M.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 728 - 731
  • [25] Sub-second functional imaging by electrical impedance tomography
    McCann, H.
    Polydorides, N.
    Murrieta-Lee, J. C.
    Ge, Kou
    Beatty, P.
    Pomfrett, C. J. D.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2086 - +
  • [26] Roles of electrical impedance tomography in lung transplantation
    Jiang, Hui
    Han, Yijiao
    Zheng, Xia
    Fang, Qiang
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [27] New methods of imaging in electrical impedance tomography - A comparative study
    Sikora, R
    Filipowicz, S
    Giza, Z
    Sikora, J
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2000, 19 (02) : 346 - 351
  • [28] A 13-Channel 1.53-mW 11.28-mm2 Electrical Impedance Tomography SoC Based on Frequency Division Multiplexing for Lung Physiological Imaging
    Liu, Boxiao
    Wang, Guoxing
    Li, Yongfu
    Zeng, Lei
    Li, Hui
    Gao, Yue
    Ma, Yixin
    Lian, Yong
    Heng, Chun-Huat
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (05) : 938 - 949
  • [29] In situ imaging of paste extrusion using electrical impedance tomography
    West, RM
    Scott, DM
    Sunshine, G
    Kostuch, J
    Heikkinen, L
    Vauhkonen, M
    Hoyle, BS
    Schlaberg, HI
    Hou, R
    Williams, RA
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (12) : 1890 - 1897
  • [30] Electrical Impedance Tomography for Biomedical Applications: Circuits and Systems Review
    Wu, Yu
    Hanzaee, Farnaz Fahimi
    Jiang, Dai
    Bayford, Richard H.
    Demosthenous, Andreas
    IEEE OPEN JOURNAL OF CIRCUITS AND SYSTEMS, 2021, 2 : 380 - 397