The Reliability of CO2 Measurements Using Low-Cost Sensors: A Study of Sensor Positioning and Ventilation Strategies in Classrooms

被引:0
作者
Marin, Daniel [1 ,2 ,3 ]
Alegria-Sala, Alba [4 ]
Casals, Lluc Canals [4 ,5 ]
Macarulla, Marcel [4 ,6 ]
Fonollosa, Jordi [1 ,2 ,3 ]
机构
[1] Univ Politecn Catalunya BarcelonaTech, Inst Res & Innovat Hlth IRIS, B2SLab, Barcelona, Spain
[2] Networking Biomed Res Ctr Subject Area Bioengn Bio, Madrid, Spain
[3] Inst Recerca Sant Joan Deu IRSJD, Barcelona, Spain
[4] Univ Politecn Catalunya BarcelonaTech, Dept Project & Construction Engn, Barcelona, Spain
[5] Grp Environm Engn ENMA, Barcelona, Spain
[6] Grp Construct Res & Innovat GR, Barcelona, Spain
关键词
air quality; air ventilation; CO2; monitoring; school monitoring; sensor position; INDOOR AIR-QUALITY; SCHOOL BUILDINGS; CARBON-DIOXIDE; TEMPERATURE; DEVICE; HEALTH;
D O I
10.1155/ina/5517242
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The COVID-19 emergency evidenced the value of keeping indoor spaces properly ventilated, which increased the interest in CO2 loggers. However, when monitoring, many significant variables are often overlooked, such as sensor specifications, the position of the system with respect to the airflow path (or occupants), and the relationship between these variables and the ventilation system of the room. With the purpose of properly standardizing future indoor air quality measurements in classroom settings, this study evaluated the results of a measurement campaign consisting of 33 individual measurements performed on site during 5 months in primary schools and university classrooms. This work uses dCO(2)/dt to identify CO2 tendencies while taking into account classroom topology and ventilation. Results show that variables such as their position and the ventilation strategy of the room often outweigh the sensor specifications, causing spatial discrepancies beyond 100 ppm. Along with the results, recommendations for future measurements are discussed in order to avoid nonrepresentative estimations of the CO2 level of indoor spaces.
引用
收藏
页数:14
相关论文
共 48 条
  • [1] Olesen B.W., Revision of en 15251: indoor environmental criteria, REHVA Journal, 49, pp. 6-12, (2012)
  • [2] Seppanen O.A., Fisk W.J., Mendell M.J., Association of ventilation rates and CO<sub>2</sub> concentrations with health and other responses in commercial and institutional buildings, Indoor Air, 9, pp. 226-252, (1999)
  • [3] Daisey J.M., Angell W.J., Apte M.G., Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information, Indoor Air, 13, pp. 53-64, (2003)
  • [4] Siskos P.A., Bouba K.E., Stroubou A.P., Determination of selected pollutants and measurement of physical parameters for the evaluation of indoor air quality in school buildings in Athens, Greece, Indoor and Built Environment, 10, pp. 185-192, (2001)
  • [5] Wargocki P., Porras-Salazar J.A., Contreras-Espinoza S., The relationship between classroom temperature and children’s performance in school, Building and Environment, 157, pp. 197-204, (2019)
  • [6] Sarbu I., Sebarchievici C., Aspects of indoor environmental quality assessment in buildings, Energy and Buildings, 60, pp. 410-419, (2013)
  • [7] Refrigerating and Air-Conditioning Engineers (ASHRAE), ASHRAE Position Document on Indoor Carbon Dioxide, (2025)
  • [8] Persily A., Challenges in developing ventilation and indoor air quality standards: the story of ASHRAE Standard 62, Building and Environment, 91, pp. 61-69, (2015)
  • [9] Refrigerating and Air-Conditioning Engineers (ASHRAE), COVID-19: one page guidance documents, (2021)
  • [10] COVID-19 Ventilation and Building Services Guidance for School Personnel, (2020)