Seismic performance of composite shear walls with end columns and built-in steel plate

被引:2
作者
Ma, Kaize [1 ,2 ]
Lin, Guirui [1 ]
Xing, Guohua [1 ]
Liao, Tao [1 ]
机构
[1] Changan Univ, Sch Civil Engn, Xian 710000, Peoples R China
[2] Changan Univ, Key Lab Transport Bridge Detect Reinforcement Tech, Xian 710000, Peoples R China
基金
中国国家自然科学基金;
关键词
Composite shear wall; Built-in steel plate; End columns; Numerical simulation; Parametric analysis; BEHAVIOR;
D O I
10.1016/j.istruc.2024.108069
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Three new full-size partially encased composite shear walls were tested under cyclic loading by varying the thickness of the steel members (built-in steel plate, stiffeners, and steel tubes) and the number of stiffeners as variables. As the number of stiffeners increased, the horizontal displacement of the specimens exhibited an oblique layered distribution. Furthermore, increasing the thickness of the steel members led the horizontal displacement of the specimens along the height directions to change more linearly before yielding, but the specimen still showed bending failure. With the increase in the number of stiffeners, the displacement of the specimen along the height direction of the wall changed linearly throughout the loading process, and the stiffness degradation was mitigated. An increase in both the thickness of the steel members and the number of stiffeners increased the force transferred to the steel members. At the end of loading, the average strength degradation coefficients of the three specimens were 0.95, 0.95, and 0.92. The main specimen parameters were analyzed using OpenSees. The results showed that the axial compression ratio of the specimen should not exceed 0.3, and the thickness of the steel tubes should be controlled at 5 mm. In addition, the adverse effect on the seismic performance of the specimens was reduced when the shear-span ratio was greater than 2.43. Finally, the stiffeners and built-in steel plate had no significant effect on the seismic performance of the specimens when their thickness varied from 3 mm to 8 mm.
引用
收藏
页数:22
相关论文
共 50 条
[41]   Research on seismic performance of precast steel-concrete composite tube shear walls with horizontal joint [J].
Dang, Longji ;
Pang, Rui ;
Liu, Yuhao ;
Wang, Yixiao ;
Wang, Lu ;
Yang, Jian .
ENGINEERING STRUCTURES, 2022, 250
[42]   Seismic Design and Performance Evaluation of Coupled Steel Plate and Reinforced Concrete Composite Walls [J].
Liu, Aozhou ;
Wu, Yuntian ;
Wang, Bin ;
Chen, Xiyue .
BUILDINGS, 2023, 13 (09)
[43]   Seismic Research and Development of Steel Plate Concrete Composite Shear Wall [J].
Yang, Yabin .
INNOVATION IN CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE, 2012, 238 :640-642
[44]   Aspect ratios of code-designed steel plate shear walls for improved seismic performance [J].
Verma, Abhishek ;
Sahoo, Dipti R. .
STEEL AND COMPOSITE STRUCTURES, 2022, 42 (01) :107-121
[45]   Seismic Performance of CFST Frame-Steel Plate Shear Walls Connected to Beams Only [J].
Rong, Qin ;
Zhao, Zhonghui ;
Guo, Lanhui ;
Hou, Xiaomeng ;
Lin, Li ;
Bi, Hongtao .
SHOCK AND VIBRATION, 2021, 2021
[46]   Seismic performance of precast concrete superposed shear walls with CFST end columns subjected to cyclic loading [J].
Zhang, Feng-Liang ;
Wu, Bian ;
Zhang, Min ;
Liu, Yang .
STRUCTURES, 2024, 68
[47]   Experimental and numerical study on seismic performance of a novel type of cold-formed steel shear wall with built-in sandwich panels [J].
Wang, Chungang ;
Qian, Haokai ;
Zhang, Zhuangnan ;
Yang, Zhenyu ;
Wang, Yiyue .
STRUCTURES, 2022, 44 :1105-1126
[48]   Seismic performance analysis of corrugated-steel-plate composite shear wall based on corner failure [J].
Luo, Qirui ;
Wang, Wei ;
Sun, Zhuangzhuang ;
Xu, Shanwen ;
Wang, Bingjie .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 180 (180)
[50]   Experiments and Numerical Simulations on the Seismic Performance of Steel-Frame Composite Wallboard Shear Walls [J].
Wang, Zhen ;
Liu, Zhe ;
Yan, Jia-Bao ;
Ju, Xiao ;
Han, Lei .
BUILDINGS, 2023, 13 (02)