Seismic performance of composite shear walls with end columns and built-in steel plate

被引:1
作者
Ma, Kaize [1 ,2 ]
Lin, Guirui [1 ]
Xing, Guohua [1 ]
Liao, Tao [1 ]
机构
[1] Changan Univ, Sch Civil Engn, Xian 710000, Peoples R China
[2] Changan Univ, Key Lab Transport Bridge Detect Reinforcement Tech, Xian 710000, Peoples R China
基金
中国国家自然科学基金;
关键词
Composite shear wall; Built-in steel plate; End columns; Numerical simulation; Parametric analysis; BEHAVIOR;
D O I
10.1016/j.istruc.2024.108069
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Three new full-size partially encased composite shear walls were tested under cyclic loading by varying the thickness of the steel members (built-in steel plate, stiffeners, and steel tubes) and the number of stiffeners as variables. As the number of stiffeners increased, the horizontal displacement of the specimens exhibited an oblique layered distribution. Furthermore, increasing the thickness of the steel members led the horizontal displacement of the specimens along the height directions to change more linearly before yielding, but the specimen still showed bending failure. With the increase in the number of stiffeners, the displacement of the specimen along the height direction of the wall changed linearly throughout the loading process, and the stiffness degradation was mitigated. An increase in both the thickness of the steel members and the number of stiffeners increased the force transferred to the steel members. At the end of loading, the average strength degradation coefficients of the three specimens were 0.95, 0.95, and 0.92. The main specimen parameters were analyzed using OpenSees. The results showed that the axial compression ratio of the specimen should not exceed 0.3, and the thickness of the steel tubes should be controlled at 5 mm. In addition, the adverse effect on the seismic performance of the specimens was reduced when the shear-span ratio was greater than 2.43. Finally, the stiffeners and built-in steel plate had no significant effect on the seismic performance of the specimens when their thickness varied from 3 mm to 8 mm.
引用
收藏
页数:22
相关论文
共 50 条
[31]   Seismic performance analysis and evaluation of tall structures using grille-type steel plate composite shear walls [J].
Yu, Qiao ;
Wu, Hao ;
Li, Lingzhi ;
Ogail, Emadeldin ;
Liu, Qingyun ;
Zhao, Xuelian ;
Liu, Yang .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2023, 32 (13)
[32]   Steel plate shear walls with outriggers. Part II: Seismic design and performance [J].
Gorji, Meisam Safari ;
Cheng, J. J. Roger .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 137 :311-324
[33]   Effect of Column Flexural Stiffnesses on the Seismic Performance of Stiffened Steel Plate Shear Walls [J].
He, Jianian ;
Li, Yicheng ;
Lin, Shuhong ;
Dong, Xian ;
Chen, Shizhe .
BUILDINGS, 2022, 12 (11)
[34]   Seismic performance of prefabricated composite shear wall with end steel plate connection by nonlinear finite element analysis [J].
Wang, Yi ;
Guo, Chengcheng ;
You, Peibo ;
Wu, Hairong ;
Wang, Zili ;
Li, Yansong .
ELECTRONIC JOURNAL OF STRUCTURAL ENGINEERING, 2024, 24 (02) :11-18
[35]   Seismic design philosophy of special steel plate shear walls [J].
Ebadi, P. ;
Farajloomanesh, S. .
MAGAZINE OF CIVIL ENGINEERING, 2020, 95 (03) :3-18
[36]   Seismic Design and Analysis of Steel Plate Shear Walls with Coupling [J].
Borello, Daniel J. ;
Fahnestock, Larry A. .
JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (08) :1263-1273
[37]   Loading protocols for seismic qualification of steel plate shear walls [J].
Bai, Jiulin ;
Huang, Jiaxin ;
Chen, Huiming ;
Xu, Liangjin ;
Wang, Yu-Hang ;
Jin, Shuangshuang .
STRUCTURES, 2022, 38 :848-860
[38]   Research on seismic performance of ITRAC-filled double steel plate composite shear wall [J].
Zhang, Yutong ;
Du, Yansheng ;
Chen, Zhihua ;
Wang, Jianhui ;
Xu, Yong ;
Liu, Guosheng .
JOURNAL OF BUILDING ENGINEERING, 2023, 75
[39]   Experimental study of the hysteretic behaviour of corrugated steel plate shear walls and steel plate reinforced concrete composite shear walls [J].
Wang, Wei ;
Ren, Yingzi ;
Lu, Zheng ;
Song, Jiangliang ;
Han, Bin ;
Zhou, Ying .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 160 :136-152
[40]   Optimization of concrete/steel thickness ratio in composite steel plate shear walls (CSSWs) [J].
Hatami, F. ;
Rahai, A. ;
Hoseinzadeh, L. .
COMPUTER AIDED OPTIMUM DESIGN IN ENGINEERING XI, 2009, 106 :173-184