In Vivo Pressure Responses of the Cervical Cerebrospinal Fluid in a Porcine Model of Extension and Flexion Whiplash Exposures

被引:0
|
作者
Soltan, Nikoo [1 ,2 ,3 ,4 ]
Svensson, Mats Y. [5 ]
Jones, Claire F. [6 ,7 ]
Cripton, Peter A. [2 ,3 ,4 ,8 ]
Siegmund, Gunter P. [9 ,10 ]
机构
[1] Univ British Columbia, Dept Mech Engn, Vancouver, BC, Canada
[2] Blusson Spinal Cord Ctr, Orthopaed & Injury Biomech Grp, ICORD, Vancouver, BC, Canada
[3] Blusson Spinal Cord Ctr, Dept Mech Engn, Vancouver, BC, Canada
[4] Blusson Spinal Cord Ctr, Dept Orthopaed, Vancouver, BC, Canada
[5] Chalmers Univ Technol, Div Vehicle Safety Mech & Maritime Sci, Gothenburg, Sweden
[6] Univ Adelaide, Sch Elect & Mech Engn, Adelaide, SA, Australia
[7] Univ Adelaide, Ctr Orthopaed & Trauma Res, Adelaide Spinal Res Grp, Adelaide, SA, Australia
[8] Univ British Columbia, Sch Biomed Engn, Vancouver, BC, Canada
[9] MEA Forens Engineers & Scientists, Laguna Hills, CA 92653 USA
[10] Univ British Columbia, Sch Kinesiol, Vancouver, BC, Canada
关键词
Whiplash injury; Cervical spine; Cerebrospinal fluid; Pressure; Pig; DISORDERS; INJURY; BIOMECHANICS; ANATOMY; SPRAINS; SPINE; PAIN;
D O I
10.1007/s10439-025-03695-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose The mechanisms of whiplash injury remain poorly understood. One theory suggests that the characteristic inertial loading of the head and neck in motor vehicle collisions can produce injurious cerebrospinal fluid (CSF) pressure transients in the cervical spine. However, these in vivo CSF pressure responses have not yet been adequately characterized. Methods This study used a pig model to characterize the cervical CSF pressure responses to head kinematic inputs in extension (simulating low-speed rear-end collisions with no head restraint) and flexion (simulating low-speed frontal collisions). We also compared the pressure and pressure impulses at three spinal levels to determine if the pressure transient responses differ spatially. Four anesthetized pigs were instrumented with intrathecal pressure transducers placed at the C2, C5, and C7 levels. A servomotor system was programmed to actuate the head through specific trajectories to model two extension, and two flexion, whiplash exposures. Results During the extension tests, mean peak pressure transients ranged from - 31.2 to 148.7 mmHg, whereas during the flexion tests, mean peak pressure transients ranged from - 50.8 to 126.9 mmHg. Peak individual responses ranged from - 71.1 to 244.8 mmHg across all tests. Pressure impulses reached a maximum of 6.77 mmHg<middle dot>s. Peak pressure and pressure impulses were largest at the C5 and C7 levels during extension exposures and at the C2 level in flexion exposures. Conclusion The reported pressure and pressure impulse responses could be used to determine neural tissue tolerances relevant to whiplash injury and contribute to the development and validation of computational models of whiplash.
引用
收藏
页码:1165 / 1179
页数:15
相关论文
共 39 条
  • [31] Neural Tissue Motion Impacts Cerebrospinal Fluid Dynamics at the Cervical Medullary Junction: A Patient-Specific Moving-Boundary Computational Model
    Soroush Heidari Pahlavian
    Francis Loth
    Mark Luciano
    John Oshinski
    Bryn A. Martin
    Annals of Biomedical Engineering, 2015, 43 : 2911 - 2923
  • [32] Neural Tissue Motion Impacts Cerebrospinal Fluid Dynamics at the Cervical Medullary Junction: A Patient-Specific Moving-Boundary Computational Model
    Pahlavian, Soroush Heidari
    Loth, Francis
    Luciano, Mark
    Oshinski, John
    Martin, Bryn A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (12) : 2911 - 2923
  • [33] Study protocol for an observational study of cerebrospinal fluid pressure in patients with degenerative cervical myelopathy undergoing surgical deCOMPression of the spinal CORD: the COMP-CORD study
    Zipser, Carl Moritz
    Pfender, Nikolai
    Spirig, Jose Miguel
    Betz, Michael
    Aguirre, Jose
    Hupp, Markus
    Farshad, Mazda
    Curt, Armin
    Schubert, Martin
    BMJ OPEN, 2020, 10 (09):
  • [34] Detrimental effects of cerebrospinal fluid pressure elevation on spinal cord perfusion: first-time direct detection in a large animal model
    Haunschild, Josephina
    von Aspern, Konstantin
    Khachatryan, Zara
    Bianchi, Edoardo
    Friedheim, Till
    Wipper, Sabine
    Trepte, Constantin J.
    Ossmann, Susann
    Borger, Michael A.
    Etz, Christian D.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (02) : 286 - 293
  • [35] Evaluating the Effects of Cerebrospinal Fluid Protein Content on the Performance of Differential Pressure Valves and Antisiphon Devices Using a Novel Benchtop Shunting Model
    Gorelick, Noah L.
    Serra, Riccardo
    Iyer, Rajiv
    Um, Richard
    Grewal, Angad
    Monroe, Audrey
    Antoine, Hannah
    Beharry, Kelly
    Cecia, Arba
    Kroll, Francesca
    Ishida, Wataru
    Perdomo-Pantoja, Alexander
    Xu, Risheng
    Loth, Francis
    Ye, Xiaobu
    Suk, Ian
    Tyler, Betty
    Bayston, Roger
    Luciano, Mark G.
    NEUROSURGERY, 2020, 87 (05) : 1046 - 1054
  • [36] Rat model of spinal cord injury preserving dura mater integrity and allowing measurements of cerebrospinal fluid pressure and spinal cord blood flow
    Soubeyrand, Marc
    Laemmel, Elisabeth
    Court, Charles
    Dubory, Arnaud
    Vicaut, Eric
    Duranteau, Jacques
    EUROPEAN SPINE JOURNAL, 2013, 22 (08) : 1810 - 1819
  • [37] Validation of a novel minimally invasive intervertebral disc pressure sensor utilizing in-fiber Bragg gratings in a porcine model -: An ex vivo study
    Dennison, Christopher R.
    Wild, Peter M.
    Dvorak, Marcel F.
    Wilson, David R.
    Cripton, Peter A.
    SPINE, 2008, 33 (17) : E589 - E594
  • [38] Estimation of Cervical Spinal Loading and Internal Motion at Adjacent Segments after C5-C6 Fusion Using a Musculoskeletal Multi-Body Dynamics Model during the Head Flexion-Extension Movement
    Diao, Hao
    Xin, Hua
    Jin, Zhongmin
    APPLIED SCIENCES-BASEL, 2024, 14 (01):
  • [39] Novel pulsatile cerebrospinal fluid model to assess pressure manometry and fluid sampling through spinal needles of different gauge: support for the use of a 22 G spinal needle with a tapered 27 G pencil-point tip
    Ginosar, Y.
    Smith, Y.
    Ben-Hur, T.
    Lovett, J. M.
    Clements, T.
    Ginosar, Y. D.
    Davidson, E. M.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (02) : 308 - 315