Establishment of diagnostic reference levels and estimation of effective dose from computed tomography head scans at a tertiary hospital in South Africa

被引:0
作者
Nyathi M. [1 ]
机构
[1] Department of Medical Physics, Faculty of Health Sciences, Sefako Makgatho Health Sciences University
关键词
Absorbed Dose; Computed Tomography; Dose; Effective Dose;
D O I
10.22038/ijmp.2019.39685.1531
中图分类号
学科分类号
摘要
Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DRLs for CT head procedures and estimate effective dose (ED). Material and Methods: The dose absorbed by the head slice of a Rando Alderson phantom was measured using calibrated lithium fluoride thermoluminescent dosimeters (TLDs) exposed to a CT scanner operated on clinical parameters. The measurements were done at the periphery and center of the slice, and repeated twice with a new set of TLDs. The radiation dose absorbed by the TLDs was read using a Harshaw TLD reader, Model 5500. The measured doses were used to calculate the weighted CT dose index (CTDIw), CT dose index volume (CTDIv), and dose length product (DLP). Finally, the ED was calculated using the formula; ED = k × DLP, where k was considered as 0.0021. Results: The mean absorbed dose was 30.9 mGy, while the established CTDIv and DLP values for the head protocol were 40 mGy and 990 mGy.cm, respectively. Additionally, the ED was calculated as 2.1 mSv. These values compared well with some international values. Conclusion: According to the results of the present study, the established CTDIv, DLP, and ED for head scan were well-compared with some international values, except in the cases using different scan lengths and scanner algorithms. © 2020 Mashhad University of Medical Sciences.
引用
收藏
页码:99 / 106
页数:7
相关论文
共 35 条
[21]  
102 Managing Patient Dose in Multi-Detector Computed Tomography (MDCT), (2008)
[22]  
Toosi M.T.B., Gholamhosseinian H., Noghreiyan A.V., Assessment of the effects of radiation type and energy type on the Calibration of TLD-100, Iran J Med Phys., 15, pp. 140-145, (2018)
[23]  
Ebrahimi Tazehmahalleh F., Gholamhosseinian H., Layegh M., Ebrahimi Tazehmahalleh N., Esmaily H., Determining rectal dose through cervical cancer radiotherapy by 9 MV photon beam using TLD and XR type T GAFCHROMIC® Film 5, Iran J Radiat Res., 129, (2008)
[24]  
Burke Burke K., Sutton D., Optimization and Deconvolution of Lithium Fluoride TLD-100 in Diagnostic radiology, Brit J Radiol., 70, 1779, pp. 261-271, (1997)
[25]  
Najafi M., Deevband M.R., Ahmadi M., Kardan M.R., Establishment of diagnostic reference levels for multi-detector computed tomography examination in Iran, Australas Phys Sci Med., 38, pp. 603-609, (2015)
[26]  
Janbabanezhad R.A., Shabestani-Monfared A., Deevbad MR, Abdi R, Nabahati M, Dose Assessment in computed Tomography Examination and establishment of diagnostic reference levels in Mazandaran, Iran. J Biomed Phys Eng., 5, 4, pp. 177-183, (2015)
[27]  
Cho P.K., Seo B.K., Choi T.K., The Development of a diagnostic rreference level on patient dose for CT in Korea, Radiation protection Dosimetry, pp. 1-6, (2007)
[28]  
Tavakoli M.B., Heydari K., Jafari S., Evaluation of Diagnostic reference levels for CT scan in Isfan, Global Journal of Medicne Research and Studies, 1, 4, pp. 130-134, (2014)
[29]  
Saravanakumar A., Vaideki K., Govindarajan K.N., Devanand B., Jayakumar S., Sharma S.D., Establishment of CT diagnostic reference levels in select procedures in South India, International Journal of Radiation Research., 14, 4, pp. 341-347, (2016)
[30]  
Muhogora W.E., Nyanda A.M., Ngoye W.M., Shao D., Radiation doses to patients during selected CT procedures at four hospitals in Tanzania, European journal of radiology., 57, 3, pp. 461-467, (2006)