Establishment of diagnostic reference levels and estimation of effective dose from computed tomography head scans at a tertiary hospital in South Africa

被引:0
作者
Nyathi M. [1 ]
机构
[1] Department of Medical Physics, Faculty of Health Sciences, Sefako Makgatho Health Sciences University
关键词
Absorbed Dose; Computed Tomography; Dose; Effective Dose;
D O I
10.22038/ijmp.2019.39685.1531
中图分类号
学科分类号
摘要
Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DRLs for CT head procedures and estimate effective dose (ED). Material and Methods: The dose absorbed by the head slice of a Rando Alderson phantom was measured using calibrated lithium fluoride thermoluminescent dosimeters (TLDs) exposed to a CT scanner operated on clinical parameters. The measurements were done at the periphery and center of the slice, and repeated twice with a new set of TLDs. The radiation dose absorbed by the TLDs was read using a Harshaw TLD reader, Model 5500. The measured doses were used to calculate the weighted CT dose index (CTDIw), CT dose index volume (CTDIv), and dose length product (DLP). Finally, the ED was calculated using the formula; ED = k × DLP, where k was considered as 0.0021. Results: The mean absorbed dose was 30.9 mGy, while the established CTDIv and DLP values for the head protocol were 40 mGy and 990 mGy.cm, respectively. Additionally, the ED was calculated as 2.1 mSv. These values compared well with some international values. Conclusion: According to the results of the present study, the established CTDIv, DLP, and ED for head scan were well-compared with some international values, except in the cases using different scan lengths and scanner algorithms. © 2020 Mashhad University of Medical Sciences.
引用
收藏
页码:99 / 106
页数:7
相关论文
共 35 条
[1]  
Liang C.R., Chen P.X., Kapur J., Ong M.K., Quek S.T., Kapur S.C., Establishment of institutional diagnostic reference level for computed tomography with automated dose-tracking software, J Med Radiat Sci., 64, pp. 82-89, (2017)
[2]  
Damilakis J., How to measure CT doses, ESR EuroSafe Imaging -Experts & Partners
[3]  
Limchareon S., Kaowises K., Saensawas W., Management of radiation dose reduction in computed tomography: an experience at burapha university hospital, Thailand, Radiol Diagn Imaging., 2, 1, pp. 1-4, (2018)
[4]  
Brenner D.J., Elliston C.D., Hall E.J., Berdom W.E., Estimated risks of Radiation induced Fatal Cancer from Pediatric CT, AJR., 176, pp. 289-296, (2001)
[5]  
Power S.P., Moloney F., Towey M., James K., O'Connor O.J., Maher M.M., Computed Tomography and patient risks: Facts, perceptions and uncertainties, World J Radiol., 8, 12, pp. 902-912, (2016)
[6]  
Frush D.P., Donnelly L.F., Rosen N.S., Computed Tomography and Radiation Risks: What Pediatric Health Care Providers Should Know, Pediatrics, 112, 4, (2003)
[7]  
Kalra M.K., Sodickson A.D., Mayo-Smith W.W., CT radiation: key concepts for gentle and wise use, Radiographics., 35, 6, pp. 1706-1721, (2015)
[8]  
Okeji M.C., Ibrahim N.S., Geoffrey L., Abukar F., Ahamed A., Evaluation of absorbed dose and Protocols during brain Computed Tomography scans in Nigerian Tertiary Hospital, World J Med Sci., 13, 4, pp. 251-254, (2016)
[9]  
Tsushima Y., Taketomi-Takahashi A., Takei H., Otake H., Endo K., Radiation exposure from CT examinations in Japan, BMC medical imaging., 10, 1, (2010)
[10]  
Chipiga L., Vodovatov A., Golikov V., Zvonova I., Bernhardsson C., Potential for the establishment of national CT diagnostic reference levels in the Russian Federation, InInternational Conference on Radiation Protection in Medicine., 11, (2017)