Differences in kinematics and kinetics during gait between total knee arthroplasty implant designs

被引:0
|
作者
Nishizawa, Kohei [1 ]
Harato, Kengo [1 ]
Hakukawa, Satoshi [1 ]
Kobayashi, Shu [1 ]
Niki, Yasuo [2 ]
Nagura, Takeo [3 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, 35 Shinanomachi,Shinjuku Ku, Tokyo 1608582, Japan
[2] Fujita Med Innovat Ctr, Dept Orthopaed Surg, Ohta Ku, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Clin Biomech, Shinjuku Ku, Tokyo, Japan
关键词
Total knee arthroplasty; Bi-cruciate stabilized total knee arthroplasty; Gait analysis; Kinematics; STABILIZED TOTAL KNEE; REPLACEMENT; POSTERIOR; STAIR; SATISFACTION; OUTCOMES; FLEXION; MOTION;
D O I
10.1016/j.clinbiomech.2024.106404
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Implant design is important for achieving proper knee biomechanics during gait following knee arthroplasty. Bicruciate-stabilized total knee arthroplasty attempts to replicate anterior stability and rotational facilitation. However, its detailed gait biomechanics compared with other implant designs have not been analyzed. The purpose of this study is to compare knee kinematics and kinetics between bicruciate-stabilized total knee arthroplasty, posterior-stabilized total knee arthroplasty, unicompartmental knee arthroplasty, and normal knees. Methods: Ten healthy subjects, 16 who underwent posterior stabilized total knee arthroplasty, 12 who underwent bicruciate-stabilized total knee arthroplasty, and 13 who underwent unicompartmental knee arthroplasty were recruited. The mean follow-up period after arthroplasty was 11.0 months. Three-dimensional kinematics and kinetics were assessed using a motion capture system with subjects walking on a 5-m walkway. Comparisons between groups were conducted using the Kruskal-Wallis test, and post hoc analysis was performed for those parameters that differed significantly. Findings: The bicruciate-stabilized total knee arthroplasty group showed decreased internal rotation compared to the unicompartmental knee arthroplasty group. Compared to the control group, the posterior-stabilized total knee arthroplasty group exhibited reduced knee extension and internal rotation moment. Interpretation: Bicruciate-stabilized total knee arthroplasties exhibited different biomechanical characteristics compared to unicompartmental knee arthroplasties during terminal stance. Postoperative total knee arthroplasty rehabilitation should focus on relieving stiffness owing to insufficient knee flexion-extension motion observed in both bicruciate-stabilized and posterior-stabilized total knee arthroplasties compared with unicompartmental knee arthroplasty, which may be due to a lack of knee rotational motion during gait.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Rationale and Results for Fixed-Bearing Pivoting Designs in Total Knee Arthroplasty
    Banks, Scott A.
    Deckard, Evan
    Hodge, W. Andrew
    Meneghini, R. Michael
    JOURNAL OF KNEE SURGERY, 2019, 32 (07) : 590 - 595
  • [22] No Differences Identified in Transverse Plane Biomechanics Between Medial Pivot and Rotating Platform Total Knee Implant Designs
    Papagiannis, Georgios I.
    Roumpelakis, Ilias M.
    Triantafyllou, Athanasios I.
    Makris, Ioannis N.
    Babis, George C.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (08) : 1814 - 1820
  • [23] Slow gait speed after bilateral total knee arthroplasty is associated with suboptimal improvement of knee biomechanics
    Ro, Du Hyun
    Han, Hyuk-Soo
    Lee, Dong Yeon
    Kim, Seong Hwan
    Kwak, Yoon-Ho
    Lee, Myung Chul
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (06) : 1671 - 1680
  • [24] The Influence of Implant Position on Final Clinical Outcome and Gait Analysis after Total Knee Arthroplasty
    Jablonski, Jaroslaw
    Sibinski, Marcin
    Polguj, Michal
    Kowalczewski, Jacek
    Marczak, Dariusz
    Faflik, Lukasz
    Jablonska, Dorota
    JOURNAL OF KNEE SURGERY, 2019, 32 (09) : 891 - 896
  • [25] Differences in Trochlear Surface Damage and Wear Between Three Different Total Knee Arthroplasty Designs
    Matz, Jacob
    Howard, James L.
    Sisko, Zachary W.
    Teeter, Matthew G.
    Lanting, Brent A.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (12) : 3763 - 3770
  • [26] Does flexion of the femoral implant in total knee arthroplasty increase knee flexion: A randomised controlled trial
    Murphy, Michael
    Journeaux, Simon
    Hides, Julie
    Russell, Trevor
    KNEE, 2014, 21 (01) : 257 - 263
  • [27] Complications and Implant Survival of Total Knee Arthroplasty in People with Hemophilia
    Carlos Rodriguez-Merchan, Emerito
    De la Corte-Rodriguez, Hortensia
    Alvarez-Roman, Teresa
    Gomez-Cardero, Primitivo
    Encinas-Ullan, Carlos A.
    Jimenez-Yuste, Victor
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (21)
  • [28] Design and kinematics in total knee arthroplasty
    Digennaro, Vitantonio
    Zambianchi, Francesco
    Marcovigi, Andrea
    Mugnai, Raffaele
    Fiacchi, Francesco
    Catani, Fabio
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (02) : 227 - 233
  • [29] Kinematics of the stiff total knee arthroplasty
    Pereira, Gavin C.
    Walsh, Michael
    Wasserman, Bradley
    Banks, Scott
    Jaffe, William L.
    Di Cesare, Paul E.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (06) : 894 - 901
  • [30] Comparison of Knee Kinematics and Kinetics during Stair Descent in Single- and Multi-Radius Total Knee Arthroplasty
    Sumner, Bonnie
    McCamley, John
    Jacofsky, David J.
    Jacofsky, Marc C.
    JOURNAL OF KNEE SURGERY, 2020, 33 (10) : 1020 - 1028